G3VM-61GR1 MOS FET Relays MOS FET Relays with 1-A switching Designed for Switching Minute Signals and Analog Signals. Upgraded G3VM-S1 Series. Continuous load current of 1 A. Note: The actual product is marked differently from the RoHS compliant image shown here. Application Examples Terminal Arrangement/Internal Connections 43 Semiconductor test equipment Mold pin mark * OMRON logo Test & Measurement equipment Model name 932 LOT.No. Pin 1 mark Communication equipment Data loggers 12 Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. List of Models Minimum package quantity Load voltage Package type Contact form Terminals Model (peak value) * Number per tube Number per tape and reel G3VM-61GR1 100 - 1a SOP4 Surface-mounting Terminals 60 V (SPST-NO) G3VM-61GR1 (TR) -2,500 * The AC peak and DC value are given for the load voltage. Absolute Maximum Ratings (Ta = 25 C) Item Symbol Rating Unit Measurement conditions LED forward current IF 50 mA Repetitive peak LED forward current IFP 1 A 100 s pulses, 100 pps LED forward current reduction rate IF/C 0.5 mA/C Ta 25C LED reverse voltage VR 5 V Connection temperature TJ 125 C Load voltage (AC peak/DC) VOFF 60 V Continuous load current (AC peak/DC) IO 1000 mA ON current reduction rate IO/C 13.3 mA/C Ta 25C Connection temperature TJ 125 C Dielectric strength between VI-O 1500 Vrms AC for 1 min I/O (See note 1.) Note: 1. The dielectric strength between the input and Ambient operating temperature Ta 20 to +85 C With no icing or condensation output was checked by applying voltage Ambient storage temperature Tstg 40 to +125 C With no icing or condensation between all pins as a group on the LED side and Soldering temperature -260 C10 s all pins as a group on the light-receiving side. Electrical Characteristics (Ta = 25 C) Item Symbol Minimum Typical Maximum Unit Measurement conditions LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times Reverse current IR - - 10 A VR = 5 V IF 1 4 RL VDD Capacity between terminals CT - 15 - pF V = 0, f = 1 MHz VOUT 2 3 Trigger LED forward current IFT -1.0 3 mA IO = 100 mA Maximum resistance with output ON RON -0.25 0.7 IF = 5 mA, IO = 1 A Current leakage when the relay is open ILEAK -0.2 100 nA VOFF = 60 V Capacity between terminals Coff - 90 - pF V = 0, f = 1 MHz IF Capacity between I/O terminals CI-O - 0.8 - pF f = 1 MHz, VS = 0 V Insulation resistance between I/O terminals RI-O 1000 - - M VI-O = 500 VDC, ROH 60 % 90% VOUT Turn-ON time tON -1.4 3.0 ms IF = 5 mA, RL = 200 , 10% t ON t OFF Turn-OFF time tOFF -0.6 1.0 ms VDD = 20 V (See note 2.) 1 Output Input Output InputG3VM-61GR1 MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD - - 48 V Operating LED forward current IF 5 10 20 mA Continuous load current (AC peak/DC) IO - - 1000 mA Ambient operating temperature Ta 25 - 60 C Engineering Data LED forward current vs. Ambient Continuous load current vs. Ambient LED forward current vs. LED forward temperature temperature voltage IF - Ta IO - Ta IF - VF 100 1.2 100 Ta = 25 C 50 1 30 80 0.8 10 60 5 0.6 3 40 0.4 1 0.5 20 0.2 0.3 0.1 0 0 0.6 0.8 1 1.2 1.4 1.6 1.8 -20 020 40 60 80 100 120 -20 020 40 60 80 100 120 Ambient temperature Ta (C) LED forward voltage VF (V) Ambient temperature Ta (C) Continuous load current vs. On-state On-state resistance vs. Ambient Trigger LED forward current vs. voltage temperature Ambient temperature IO - VON RON - Ta IFT - Ta 1.2 0.8 1.4 Ta = 25 C 1.0 IO = 1 A IO = 0.1 A IF = 5 mA 0.7 1.2 IF = 5 mA 0.8 0.6 0.6 1.0 0.4 0.5 0.2 0.8 0 0.4 0.6 -0.2 0.3 -0.4 0.4 -0.6 0.2 -0.8 0.2 0.1 -1.0 -1.2 0 0.0 -300-250-200-150-100 -50 0 50 100 150 200 250 300 -20 020 40 60 80 100 -20 020 40 60 80 100 On-state voltage VON (mV) Ambient temperature Ta (C) Ambient temperature Ta (C) Turn ON, Turn OFF time vs. LED Turn ON, Turn OFF time vs. Ambient Current leakage vs. Ambient forward current temperature temperature tON, tOFF - IF tON, tOFF - Ta ILEAK - Ta 10 VDD = 20 V Ta = 25 C VOFF = 60 V 5 RL = 200 , IF = 5 mA VDD = 20 V, RL = 200 3 10 10 1 0.5 tON 0.3 ttOFF 1 1 tOFF 0.1 0.05 ttON 0.03 0.01 0.1 0.1 -20 020 40 60 80 100 110 -20 020 40 60 80 100 LED forward current IF (mA) Ambient temperature Ta (C) Ambient temperature Ta (C) Safety Precautions Refer toCommon Precaution for all G3VM models. 2 Continuous load current IO (A) LED forward current IF (mA) Turn ON, Turn OFF time tON, tOFF (ms) Turn ON, Turn OFF time tON, tOFF (ms) Continuous load current IO (A) On-state resistance RON ( ) Trigger LED forward current IFT (mA) Current leakage ILEAK (nA) LED forward current IF (mA)