G5SB PCB Power Relay Compact Single-pole Relay for Switching 5 A Compact SPDT Relay Incorporates a normally open contact that switches 5 A max. (N.O. contacts) Small, yet provides 8-kV impulse withstand voltage (between coil and contacts) Standard model conforms to UL/CSA/VDE standards. RoHS Compliant Model Number Legend Application Examples Ideal for output applications of control equipments 1. Number of Poles 2. Enclosure rating G5SB-14 1: 1-pole/SPDT (1c) 4: Fully sealed 12 G 5 Ordering Information Characteristics S B Contact resistance *1 100 m max. Minimum Contact Terminal Enclosure Rated coil Classification Model packing Operate time 10 ms max. form Shape rating voltage unit Release time 5 ms max. Insulation resistance *2 1,000 M min. 5 VDC Between coil 9 VDC 4,000 VAC, 50/60 Hz for 1 min SPDT PCB Fully 100 pcs/ and contacts Standard G5SB-14 (1c) terminals sealed Tray Dielectric 12 VDC Between strength 24 VDC contacts of the 1,000 VAC, 50/60 Hz for 1 min same polarity Note. When ordering, add the rated coil voltage to the model number. Impulse Between coil Example: G5SB-14 12 VDC withstand 8 kV (1.2 x 50 s) and contacts Rated coil voltage voltage 10 to 55 to 10 Hz, 0.75 mm single amplitude Destruction Ratings Vibration (1.5 mm double amplitude) resistance 10 to 55 to 10 Hz, 0.75 mm single amplitude Malfunction (1.5 mm double amplitude) Coil 2 Shock Destruction 1,000 m/s Item Must Must 2 Max. resistance Malfunction 100 m/s operate release Rated Coil Power voltage 5,000,000 operations voltage voltage Mechanical current resistance consumption (V) (18,000 operations per hour) (V) (V) (mA) () (mW) Rated 200,000 operations: 3 A (NO)/3 A (NC) at voltage % of rated voltage 125 VAC 5 VDC 80 63 50,000 operations: 5 A (NO)/3 A (NC) at 150% 125 VAC 9 VDC 44.4 202 Durability 75% 5% min. (at Approx. 400 Electrical 50,000 operations: 5 A (NO) at 250 VAC max. 12 VDC 33.3 360 23C) (resistive load) 100,000 operations: 3 A (NC) at 250 VAC 24 VDC 16.7 1,440 100,000 operations: 5 A (NO)/3 A (NC) at 30 VDC Note 1. The rated current and coil resistance are measured at a coil Switching frequency: 1,800 operations per temperature of 23C with a tolerance of 10%. hour Note 2. The operating characteristics are measured at a coil temperature of Failure rate (P level) 23C. DC5V 10mA (reference value) *3 Note 3. The Max. voltage is the maximum voltage that can be applied to the Ambient operating relay coil. 40C to 70C with no icing or condensation temperature Contacts Ambient operating humidity 5% to 85% Weight Approx. 6.5 g Item Load Resistive load Note. The data shown above are initial values. Contact type Single *1. The contact resistance is possible with 1 A applied at 5 VDC using a fall- Contact material Ag-alloy (Cd free) of-potential method. *2. The insulation resistance is possible between coil and contacts and 3 A (NO)/3 A (NC) at 125 VAC between contacts of the same polarity at 500 VDC. 5 A (NO)/3 A (NC) at 125 VAC *3. This value was measured at a switching frequency of 120 operations/min. Rated load 5 A (NO) at 250 VAC 3 A (NC) at 250 VAC 5 A (NO)/3 A (NC) at 30 VDC Rated carry current 5 A (NO)/3 A (NC) Max. switching voltage 250 VAC, 30 VDC Max. switching current 5 A (NO)/3 A (NC) 1G5SB PCB Power Relay Engineering Data Maximum Switching Capacity Ambient Temperature vs. Maximum Voltage 7 200 180 6 AC resistive (NO) 160 5 140 120 DC resistive 4 AC resistive 110 (NO) (NC) 100 3 80 DC resistive 60 2 (NC) 40 1 20 0 0 1 10 30 100 250 1,000 -40 -20 0 23 40 60 70 80 100 Note. The maximum voltage is the maximum voltage that can be applied to the relay cooil. Switching voltage (V) Ambient temperature (C) Ambient Temperature vs Must Shock Malfunction Operate and Must Release Voltages Y 100 1,000 Sample: Must operate voltage NO contact 90 G2RL-14-E 24 VDC Must release voltage Sample: G5SB-14 12 VDC Number of Relays: 5 pcs Number of Relays: 5 pcs 80 X Z NC contact Conditions: Shock is applied in X, Y, Z G 1,000 1,000 70 max. directions three times each with and without 5 X energizing the Relays to check the number 60 S min. of malfunctions. B 50 2 250 Requirement: None malfunction 100 m/s 40 1,000 1,000 Z X 30 650 20 max. Shock direction X XX 1,000 2 10 min. Unit: m/s Y Y Z -30 -20 -10 010 20 3040506070 8090 Z Y Ambient temperature (C) Dimensions (Unit: mm) PCB Mounting Holes Terminal Arrangement/ G5SB-14 (Bottom View) Internal Connections Tolerance: 0.1 mm (Bottom View) 10.3max. (10.0)* 20.3max. (20.0)* 2.54 Five, 1.30.1-dia. holes (1.19) 2.54 15.8max. (15.5)* 1 2 3 7.62 0.4 5 4 0.4 0.27 1 3.4 (No coil polarity) 10.16 2.54 5.08 7.62 (1.18) 10.16 2.54 5.08 *Values in parentheses are average values. Approved Standards UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928) Number of test Model Coil ratings Contact ratings operations 5A 250V AC N.O. only (Resistive) 40C 3A 125V AC N.O. only (Resistive) 40C G5SB 5 to 24 VDC 5A 30V DC N.O. only (Resistive) 40C 6,000 3A 250V AC N.C. only (Resistive) 40C 2A 125V AC N.C. only (Resistive) 40C EN/IEC, VDE (Approval No. 40003957) Number of test Model Coil ratings Contact ratings operations G5SB 5, 12, 24 VDC 5A(N.O)/3A(N.C) 250V AC 70C 10,000 Precautions Please refer to PCB Relays Common Precautions for correct use. 2 Must operate/must release voltage (percentage of rated voltage) (%) Switching current (A) Maximum voltage (%)