Omron 08 Cat 1-302 5/10/07 15:39 Page 186 PCB Signal Relay G5VText -1 TPCB Signal Relay G5Vext -1 Ultra-miniature, Highly Sensitive Contact Ratings SPDT Relay for Signal Circuits Load Resistive load (cos = 1) ROHS compliant. Rated Load 0.5 A at 125 VAC 1 A at 24 VDC Ultra-miniature at 12.5 x 7.5 x 10 mm Contact Material Ag (Au alloy) (L x W x H). Rated Carry Current 2 A Wide switching power of 1 mA to 1 A. Max. switching voltage 125 VAC, 60 VDC High sensitivity: 150mW nominal coil power. Max. switching current 1 A Fully sealed construction. Max. switching power 62.5 VA, 30 W Failure rate (reference value) 1 mA at 5 VDC International 2.54mm terminal pitch. -6 Note: P level: = 0.1 x 10 /operation. Conforms to FCC Part 68 requirements for 60 This value was measured at a switching frequency of 120 operaions/min and the criterion of contact resistance is 100. This coil to contacts. value may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions. Characteristics Ordering Information Contact resistance (see note 1) 100 m max. Classification Model Operate time (see note 2) 5 ms max. (mean value: approx. 2.5 ms) Contact form Contact type Contact material Structure Release time (see note 2) 5 ms max. (mean value: approx. 0.9 ms) SPDT Single crossbar AG (Au Alloy) Fully sealed G5V-1 Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr at rated load Note: When ordering, add the rated coil voltage to the model number. Insulation resistance (see note 2) 1,000 M min. (at 500 VDC between coil and contacts, at 250 VDC between contacts of same polarity.) Example: G5V-1 12 VDC Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil and contacts Rated coil voltage 400 VAC, 50/60 Hz for 1 min between contacts of same polarity Model Number Legend Impulse withstand voltage 1,500 V (10 x 160 s) between coil and contacts (conforms to FCC Part 68) Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude) G5V - VDC Malfunction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude) 2 12 Shock resistance Destruction: 1,000 m/s 1. Contact Form 2. Rated Coil Voltage 2 1: SPDT 3, 5, 6, 9, 12, 24 VDC Malfunction: 100 m/s Endurance Mechanical: 5,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (under rated load, at 1,800 operations/hr) Ambient temperature Operating: -40C to 70C (with no icing) Specifications Ambient humidity Operating: 5% to 85% Coil Ratings Weight Approx. 2 g Note: 1. The contact resistance was measured wih 10mA at 1VDC with a voltage drop method. Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 2. Values in parantheses are actual values. 3. The insulation resistance was measured with a 500VDC megohmeter between coil and contacts with a 250VDC megohmeter Rated current 50 mA 30 mA 25 mA 16.7 mA 12.5 mA 6.25 mA between contacts with the same polarity applied to the same parts as those used for checking the dielectric strength. Coil resistance 60 167 240 540 960 3,840 Approved Standards Coil inductance Armature OFF 0.05 0.15 0.20 0.45 0.85 3.48 UL (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR31928) (H) (ref. value) Armature ON 0.11 0.29 0.41 0.93 1.63 6.61 Must operate voltage 80% max. of rated voltage Model Contact form Coil ratings Contact ratings Must release voltage 10% min. of rated voltage G5V-1 SPDT 3 to 24 VDC 0.5 A, 125 VAC (general use) 0.3 A, 110 VDC (resistive load) Max. voltage 200% of rated voltage at 23C 1 A, 30 VDC (resistive load) Power consumption Approx. 150 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest that can be imposed on the relay coil. 186 187 Signal RelaysOmron 08 Cat 1-302 5/10/07 15:39 Page 186 PCB Signal Relay G5VText -1 TPCB Signal Relay G5Vext -1 Ultra-miniature, Highly Sensitive Contact Ratings SPDT Relay for Signal Circuits Load Resistive load (cos = 1) ROHS compliant. Rated Load 0.5 A at 125 VAC 1 A at 24 VDC Ultra-miniature at 12.5 x 7.5 x 10 mm Contact Material Ag (Au alloy) (L x W x H). Rated Carry Current 2 A Wide switching power of 1 mA to 1 A. Max. switching voltage 125 VAC, 60 VDC High sensitivity: 150mW nominal coil power. Max. switching current 1 A Fully sealed construction. Max. switching power 62.5 VA, 30 W Failure rate (reference value) 1 mA at 5 VDC International 2.54mm terminal pitch. -6 Note: P level: = 0.1 x 10 /operation. Conforms to FCC Part 68 requirements for 60 This value was measured at a switching frequency of 120 operaions/min and the criterion of contact resistance is 100. This coil to contacts. value may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions. Characteristics Ordering Information Contact resistance (see note 1) 100 m max. Classification Model Operate time (see note 2) 5 ms max. (mean value: approx. 2.5 ms) Contact form Contact type Contact material Structure Release time (see note 2) 5 ms max. (mean value: approx. 0.9 ms) SPDT Single crossbar AG (Au Alloy) Fully sealed G5V-1 Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr at rated load Note: When ordering, add the rated coil voltage to the model number. Insulation resistance (see note 2) 1,000 M min. (at 500 VDC between coil and contacts, at 250 VDC between contacts of same polarity.) Example: G5V-1 12 VDC Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil and contacts Rated coil voltage 400 VAC, 50/60 Hz for 1 min between contacts of same polarity Model Number Legend Impulse withstand voltage 1,500 V (10 x 160 s) between coil and contacts (conforms to FCC Part 68) Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude) G5V - VDC Malfunction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude) 2 12 Shock resistance Destruction: 1,000 m/s 1. Contact Form 2. Rated Coil Voltage 2 1: SPDT 3, 5, 6, 9, 12, 24 VDC Malfunction: 100 m/s Endurance Mechanical: 5,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (under rated load, at 1,800 operations/hr) Ambient temperature Operating: -40C to 70C (with no icing) Specifications Ambient humidity Operating: 5% to 85% Coil Ratings Weight Approx. 2 g Note: 1. The contact resistance was measured wih 10mA at 1VDC with a voltage drop method. Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 2. Values in parantheses are actual values. 3. The insulation resistance was measured with a 500VDC megohmeter between coil and contacts with a 250VDC megohmeter Rated current 50 mA 30 mA 25 mA 16.7 mA 12.5 mA 6.25 mA between contacts with the same polarity applied to the same parts as those used for checking the dielectric strength. Coil resistance 60 167 240 540 960 3,840 Approved Standards Coil inductance Armature OFF 0.05 0.15 0.20 0.45 0.85 3.48 UL (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR31928) (H) (ref. value) Armature ON 0.11 0.29 0.41 0.93 1.63 6.61 Must operate voltage 80% max. of rated voltage Model Contact form Coil ratings Contact ratings Must release voltage 10% min. of rated voltage G5V-1 SPDT 3 to 24 VDC 0.5 A, 125 VAC (general use) 0.3 A, 110 VDC (resistive load) Max. voltage 200% of rated voltage at 23C 1 A, 30 VDC (resistive load) Power consumption Approx. 150 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest that can be imposed on the relay coil. 186 187 Signal Relays