- G5V-1 Low Signal Relay Ultra-miniature, Highly Sensitive SPDT Relay for Signal Circuits Ultra-miniature at 12.5 7.5 10 mm (L W H). Wide switching power of 1 mA to 1 A. High sensitivity: 150 mW nominal coil power consumption. Fully-sealed construction offering environment resistance. Conforms to FCC Part 68 requirements for coil to contacts. (1,500 V, 10 160 s) Models for ambient temperatures up to 90C added to series. RoHS Compliant Model Number Legend Application Examples 1. Number of Poles/Contact Form Telecommunication equipment G5V- - 1: 1-pole/SPDT (1c) Audio-visual products 12 Security equipment 2. Classification G Building automation equipment None: Standard (Ambient operating temperature 70C max.) 5 V T90: Ambient operating temperature 90C max. 1 Ordering Information Standard Model Specifications Contact type: Single crossbar (Au-alloy + Ag) Enclosure Terminal Rated coil Minimum Classification Contact form Model rating Shape voltage packing unit Enclosure rating: Plastic sealed 3 VDC Terminal shape: PCB terminals 5 VDC 6 VDC Standard G5V-1 9 VDC Fully SPDT PCB 12 VDC 25 pcs/tube sealed (1c) terminals 24 VDC 5 VDC G5V-1-T90 G5V-1-T90 12 VDC 24 VDC Note: When ordering, add the rated coil voltage to the model number. Example: G5V-1 DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Ratings Coil Contacts G5V-1 (Standard) Load Resistive load Item Must operate Must release Rated Coil Max. voltage Power Contact type Single crossbar voltage voltage Rated voltage current resistance (V) consumption (V) (V) Contact (mA) () (mW) Au-alloy + Ag % of rated voltage material 3 VDC 50 60 0.5 A at 125 VAC Rated load 5 VDC 30 167 1 A at 24 VDC 6 VDC 25 240 200% at Rated carry 80% max. 10% min. Approx. 150 2 A 9 VDC 16.7 540 23C current 12 VDC 12.5 960 Max. switching 125 VAC, 60 VDC 24 VDC 6.25 3,840 voltage Max. switching G5V-1-T90 1 A current Must operate Must release Rated Coil Max. voltage Power voltage voltage Rated voltage current resistance (V) consumption (V) (V) (mA) () (mW) % of rated voltage 5 VDC 30 167 200% at 12 VDC 12.5 960 70% max. 10% min. Approx. 150 23C 24 VDC 6.25 3,840 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2.The operating characteristics are measured at a coil temperature of 23C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. 4.G5V-1-2 types with a must operate voltage of 70% max. are available as special series products. 1- G5V-1 Low Signal Relay Characteristics Contact resistance *1 100 m max. Operate time 5 ms max. Release time 5 ms max. 1,000 M min. (at 500 VDC between coil and contacts, Insulation resistance *2 at 250 VDC between contacts of same polarity.) Dielectric Between coil and contacts 1,000 VAC, 50/60 Hz for 1 min strength Between contacts of the same polarity 400 VAC, 50/60 Hz for 1 min Note: The values here are initial values. 10 to 55 to 10 Hz, 1.65 mm single amplitude Destruction *1. Measured with 10 mA at 1 VDC with a voltage drop (3.3 mm double amplitude) Vibration method. resistance 10 to 55 to 10 Hz, 1.65 mm single amplitude Malfunction *2. Measured with a 500 VDC megohmmeter between (3.3 mm double amplitude) coil and contacts and a 250 VDC megohmmeter 2 Shock Destruction 1,000 m/s between contacts with the same polarity applied to 2 resistance Malfunction 100 m/s the same parts as those used for checking the Mechanical 5,000,000 operations min. (at 36,000 operations/hr) dielectric strength. Durability 100,000 operations min. *3. This value was measured at a switching frequency Electrical (under rated load, at 1,800 operations/hr) of 120 operations/min and the criterion of contact Failure rate (P level) (reference value) *3 1 mA at 5 VDC resistance is 100 . -40C to 70C (Standard), -40C to 90C (G5V-1-T90) This value may vary depending on the switching Ambient operating temperature (with no icing or condensation) frequency and operating environment. Always Ambient operating humidity 5% to 85% double-check relay suitability under actual operating Weight Approx. 2 g conditions. G 5 V 1 2