G6E Low Signal Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98-mW (Rated power consumption: 200mW) pickup coil power. Impulse withstand voltage of 1,500V (10160 s) meets FCC requirements. Stick packing employed in consideration of supporting automatic implementation. Plastic-sealed model that allows automatic soldering. New series of ultrasonically cleanable models is available. Standard model conforms to UL/CSA standards. RoHS Compliant Model Number Legend Application Examples Telecommunication equipment G6E- - - - G Office automation machines 6 1 2 34 56 7 8 E Industrial equipment 1. Relay Function 3: Bifurcated crossbar Ag L : Low sensitivity coil Security equipment None : Single-side stable (Au-Alloy) contact (400 mW) U : Single-winding 4. Enclosure Rating 7. Approved Standards latching 4: Fully sealed US: UL, CSA K : Double-winding UL: FILE No.E41515 latching 5. Terminals Shape ( ) CSA: FILE No.LR31928 P: PCB terminals 2. Number of poles/ 8. Special Function Contact Form 6. Classification None : Standard None : Standard 1: 1-pole/SPDT (1c) U : For ultrasonically cleanable 3. Contact Type Ordering Information Standard Models (UL, CSA certified) Relay Function Single-side stable Single-winding latching Double-winding latching Classification Standard Low-sensitivity Standard Standard Low-sensitivity Minimum packing unit Rated coil Rated coil Rated coil Rated coil Rated coil Contact form Model Model Model Model Model voltage voltage voltage voltage voltage 5 VDC 5 VDC 5 VDC 5 VDC 5 VDC 6 VDC 6 VDC 6 VDC 6 VDC 6 VDC G6E G6EU G6EK G6EK 9 VDC 9 VDC 9 VDC 9 VDC G6E -134PL-US -134P-US -134P-US -134PL-US SPDT (1c) 25 pcs/tube -134P-US 12 VDC 12 VDC 12 VDC 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 48 VDC Models for Ultrasonically Cleanable Relay Function Single-side stable Single-winding latching Double-winding latching Classification Standard Low-sensitivity Standard Standard Minimum packing unit Rated coil Rated coil Rated coil Rated coil Contact form Model Model Model Model voltage voltage voltage voltage 5 VDC 5 VDC 5 VDC 5 VDC 6 VDC G6E G6EU G6EK 9 VDC G6E -134PL-US-U -134P-US-U -134P-US-U SPDT (1c) 25 pcs/tube -134P-US-U 12 VDC 12 VDC 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC 48 VDC Note: When ordering, add the rated coil voltage to the model number. Example: G6E-134P-US 5 VDC Rated coil voltage 1G6E Low Signal Relay Ratings Coil: Single-side Stable Must operate Must release Max. Rated Coil Power voltage voltage voltage Classification Rated voltage current resistance consumption (V) (V) (V) (mA) () (mW) % of rated voltage 5 VDC 40.0 125 6 VDC 33.3 180 190% 9 VDC 22.2 405 Approx. 200 (at 23C) Standard 70% max. 10% min. 12 VDC 16.7 720 24 VDC 8.3 2,880 170% 48 VDC 8.3 5,760 Approx. 400 (at 23C) 5 VDC 79.4 63 6 VDC 66.6 90 170% Low-sensitivity 9 VDC 44.3 203 70% max. 10% min. Approx. 400 (at 23C) 12 VDC 33.3 360 24 VDC 16.7 1,440 Coil: Single-winding latching Must set voltage Must reset voltage Max. voltage Power consumption Rated current Coil resistance (V) (V) (V) Contact type Rated voltage (mA) () % of rated voltage Set coil (mW) Reset coil (mW) 5 VDC 40.0 125 6 VDC 33.3 180 G Bifurcated 190% 6 9 VDC 22.2 405 70% max. 70% max. Approx. 200 Approx. 200 crossbar (at 23C) E 12 VDC 16.7 720 24 VDC 8.3 2,880 Coil: Double-winding latching Must set Must reset Max. Rated current (mA) Coil resistance () voltage voltage voltage Power consumption (V) (V) (V) Classification Rated voltage Set coil Reset coil Set coil Reset coil Set coil Reset coil % of rated voltage (mW) (mW) 5 VDC 40.0 40.0 125 125 6 VDC 33.3 33.3 180 180 190% Standard 9 VDC 22.2 22.2 405 405 70% max. 70% max. Approx. 200 Approx. 200 (at 23C) 12 VDC 16.7 16.7 720 720 24 VDC 8.3 8.3 2,880 2,880 5 VDC 79.4 79.4 63 63 6 VDC 66.6 66.6 90 90 170% Low-sensitivity 9 VDC 44.3 44.3 203 203 70% max. 70% max. Approx. 400 Approx. 400 (at 23C) 12 VDC 33.3 33.3 360 360 24 VDC 16.7 16.7 1,440 1,440 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2.Operating characteristics are measured at a coil temperature of 23C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. 4.Refer to the engineering data for relations between the ambient temperature and maximum coil voltage. Contacts Load Inductive load Resistive load Item (cos = 0.4 L/R = 7 ms) Contact type Bifurcated crossbar Contact material Ag (Au-Alloy) 0.4 A at 125 VAC 0.2 A at 125 VAC Rated load 2 A at 30 VDC 1 A at 30 VDC Rated carry current 3 A Max. switching voltage 250 VAC, 220 VDC Max. switching current 3 A 2