Solid-state Timer H3M CSM H3M DS E 2 2 Solid-state Timer with Variable Time Ranges Four time ranges are selectable per timer unit. Wide timing range of 0.05 second to 30 hours can be covered by a combination of five timer units. Standard surface mounting type is easily convertible to flush mounting type with the use of a special adapter (Y92F-40). Requires only 40 x 50 mm for mounting space. Equipped with power-ON & time-out indicators. All standard models approved by UL, CSA, and LR. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information Operation/resetting system Time-limit contact Instantaneous Mounting contact Surface mounting Flush mounting Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter Note: 1. Specify both the model number and supply voltage when ordering. 2. Sockets and adapters for surface/track mounting are available optionally and therefore, place the order for them as necessary. Timer hold-down clips (F-hook and L-hook) are supplied with the timer. Accessories (Order Separately) Adapter Y92F-40 Specifications Time Ranges Four time ranges are available for each timer by changing the time range selector switch positions to different combinations. Time range code Time range selector switch A 0.05 to 0.5 s 0.5 to 5 s 0.05 to 0.5 min 0.5 to 5 min B 0.1 to 1 s 1 to 10 s 0.1 to 1 min 1 to 10 min C 0.3 to 3 s 3 to 30 s 0.3 to 3 min 3 to 30 min Time range code Time multiplying key D 0.1 to 1 min 1 to 10 min 0.1 to 1 hrs 1 to 10 hrs E 0.3 to 3 min 3 to 30 min 0.3 to 3 hrs 3 to 30 hrs 1H3M Ratings Rated supply voltage 100/110/120 VAC (50/60 Hz), 200/220/240 VAC (50/60 Hz), 12, 24, 48, 100, 110 VDC (see note 2) Operating voltage range AC: 85% to 110% of rated supply voltage DC: 80% to 110% of rated supply voltage (see note 3) Power consumption AC: Approx. 5 VA/2 W DC: Approx. 2 W Control outputs 5 A at 250 VAC, resistive load (cos = 1) Note: 1. Color indicators for the rated voltage are provided on the front of the Timer. Blue: 100/110/120 VAC Red: 200/220/240 VAC None: Other voltages 2. With DC ratings, single-phase full-wave rectified power sources may be used. 3. 90% to 110% for 12-VDC models. Characteristics Accuracy of operating time 1% max. (see note) Setting error 10% max. Reset time 0.1 s max. Influence of voltage 1% max. (see note) Influence of temperature 2% max. (see note) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts) 1,500 VAC, 50/60 Hz for 1 min (between contact and control circuit) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude Malfunction: 10 to 55 Hz with 0.5-mm double amplitude 2 Shock resistance Destruction: 1,000 m/s (approx. 100G) 2 Malfunction: 100 m/s (approx. 10G) Ambient temperature Operating: 10C to 50C Storage: 25C to 65C Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) Approved standards UL (File No. E41515), CSA (File No. LR22310) Weight Approx. 100 g Note: For the timer with time range code A, add 10 ms to the respective characteristics when the time range selector switches are in the x 1 s (0.05 to 0.5 s) position. 2