Programmable Terminals / NT11NT21 Warranty and Limitations of Liability This catalog mainly provides information that is necessary for selecting suitable models, and does not contain precautions for correct use. Always read the precautions and other WARRANTY required information provided in product operation manuals before using the product. OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. The application examples provided in this catalog are for reference only. Check functions OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, and safety of the equipment before use. REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR Never use the products for any application requiring special safety requirements, such as PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER nuclear energy control systems, railroad systems, aviation systems, medical equipment, OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE amusement machines, vehicles, safety equipment, or other application involving serious risk REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, to life or property, without ensuring that the system as a whole has been designed to EXPRESS OR IMPLIED. address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER NT11 CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. NT21 Note: Do not use this document to operate the Unit. Regional Headquarters OMRON Corporation Authorized Distributor: FA Systems Division H.Q. OMRON EUROPE B.V. 66 Matsumoto Wegalaan 67-69, NL-2132 JD Hoofddorp Mishima-city, Shizuoka 411-8511 The Netherlands Japan Tel: (31)2356-81-300/Fax: (31)2356-81-388 Tel: (81)55-977-9181 OMRON ELECTRONICS LLC Fax: (81)55-977-9045 1 East Commerce Drive, Schaumburg, IL 60173 U.S.A. Tel: (1)847-843-7900/Fax: (1)847-843-8568 OMRON ASIA PACIFIC PTE. LTD. 83 Clemenceau Avenue, 11-01, UE Square, Singapore 239920 Tel: (65)6835-3011/Fax: (65)6835-2711 Note: Specifications subject to change without notice. Cat. No. V071-E1-02 Printed in Japan 1003-0.5MNTNTNT1111 Compact Size, High Performance Superb functionality with a compact screen size Bar Graphs can be Displayed Printout of Production Status High-speed NT Links Effective display area Two RS-232C ports Bar graph displays allow the progress of processes to be Data such as the production status and production results 117 x 63 mm checked at a glance. can be printed out, leaving a record on paper which can be (The bars are oriented horizontally.) used as a daily report. Memory Link (The NT11S has a printer port. One screen only is printed.) Supports Memory Units Up to 3,999 screens Screen Plan Prod. Concentrated functionality Line 1 200 200 Line 2 150 140 Mathematical functions Line 3 350 350 31 functional parts Recipes Alarm lists/histories Advantages From Advantages From NT20S/NT31 Image library the Standpoint of Maintenance, the Standpoint of Maintenance, data compatibility Trend graphs Analog meters Password Screens for Security Password screens cannot be accessed unless the correct NT21 Upgraded NT Support Tool password is entered. This means that the operations that Integral Numeric Key Pad Bar Code Reader can be performed can be restricted according to the version (-EV4.7) Supports RS-232C/422 operator. function Shares I/O comment data The display, numeric keys, and function keys are all Adapter (connector) with CX-Programmer integrated into the front panel, which is convenient for Symbol Manager previews designers. The key layout is ergonomically designed for ease of use. Copy image library window data Programming Console Individual editing of grouped parts function High-speed Host Link Windows XP supported Up to 115,200 bps supported between CS1/CJ1 PLCs. Long-lived Backlight Key Titles can be Marked on the Function Key Sheet Since LEDs are used for the backlight, it is very long-lived High-speed Host Link Long-lived Backlight and rarely needs to be changed. Key titles can be marked on the function key sheet in accordance with the applications of the keys: the sheet can Display History Record Helps in Analysis of be taken out from the side face of the terminal. Machine Faults The front panel of the terminal has a water-withstanding construction. When the display history record function is set as a screen Fully Compatible Example key titles: attribute, the time, the screen number, and a comment are with NT11S Full Area Access F1 F2 F3 recorded in the terminal s memory every time the relevant to CS1/CJ1 RUN AUT MAN. screen is displayed. This display history can be printed by issuing a print instruction from the host, and is useful for machine fault analysis. Example printout No. Time Screen No Screen Comment F4 STOP 1 11/01-10:00 1 LINE ERROR 2 11/07-15:33 15 MOTOR ERROR Password NT11 3 11/11-13:56 19 COMPRESSER ERROR Screens 4 11/14-09:12 5 MOTOR ERROR Simplified Ladder Programming Conforms to NEMA4 and IP65 2 3