Switch Mode Power Supply (60/90/120/180/240-W Models) S8VE CSM S8VE DS E 1 2 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1, CSA C22.2 No. 107.1/60950-1 EN 50178 (= VDE0160) Mount to DIN Rail. Complies with SEMI F47-0200 (200-VAC input). RoHS-compliant. * Refer to Safety Precautions on page 12. Model Number Structure Model Number Legend Note: Refer to List of Models in Ordering Information, below. S8VE- 24- 12 3 1. Power Ratings 060: 60 W 090: 90 W 120: 120 W 180: 180 W 240: 240 W 2. Output voltage 24: 24 V 3. Terminal Block Form None: Screw terminal block F: Screwless terminal block 1S8VE Ordering Information List of Models Note: For details on normal stock models, contact your nearest OMRON representative. Model number Model number Power ratings Input voltage Output voltage Output current (screw terminal block) (screwless terminal block) 60 W 2.5 A S8VE-06024 S8VE-06024-F 90 W 3.75 A S8VE-09024 S8VE-09024-F 120 W 100 to 240 VAC 24 V 5 A S8VE-12024 S8VE-12024-F 180 W 7.5 A S8VE-18024 S8VE-18024-F 240 W 10 A S8VE-24024 S8VE-24024-F Specifications Ratings/Characteristics Item Power ratings 60 W 90 W Efficiency (typical) 78% min. 80% min. Voltage *1 100 to 240 VAC (85 to 264 VAC) Frequency *1 50/60 Hz (47 to 450 Hz) 100-V input 1.7 A max. 2.3 A max. Current 200-V input 1.0 A max. 1.4 A max. Power factor --- Input Harmonic current emissions Conforms to EN61000-3-2 100-V input 0.5 mA max. Leakage current 200-V input 1.0 mA max. 100-V input 25 A max. (for a cold start at 25C) Inrush current *2 200-V input 50 A max. (for a cold start at 25C) Voltage adjustment range *3 10% to 15% (with V. ADJ) Ripple 2.0% (p-p) max. (at rated input/output voltage) Input variation influence 0.5% max. (at 85- to 264-VAC input, 100% load) Output Load variation influence (rated input voltage) 1.5% max. (with rated input, 0 to 100% load) Temperature variation influence 0.05%/C max. Startup time *2 1,000 ms max. (at rated input/output voltage) Hold time *2 20 ms min. (at rated input/output voltage) Overload protection *2 105% to 160% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection *2, *4 Yes Additional functions Parallel operation No Series operation Yes for up to 2 Power Supplies (with external diode) Operating ambient temperature Refer to the derating curve in Engineering Data (60-W, 90-W, 120-W, 180-W, and 240-W Models). (with no icing or condensation) Storage temperature 25 to 65C Operating ambient humidity 25% to 85% (Storage humidity: 25% to 90%) 3.0 kVAC for 1 min. (between all inputs and outputs detection current: 20 mA) Dielectric strength 2.0 kVAC for 1 min. (between all inputs and PE terminals detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals detection current: 30 mA) Insulation resistance 100 M min. (between all outputs and all inputs/ PE terminals) at 500 VDC 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions Vibration resistance 10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions 2 Shock resistance 150 m/s , 3 times each in X, Y, and Z directions Output indicator Yes (color: green) Other Conducted Conforms to EN61204-3 EN55011 Class A and based on FCC Class A Emissions EMI Radiated Conforms to EN61204-3 EN55011 Class A Emissions EMS Conforms to EN61204-3 high severity levels UL: UL508 (Listing), UL60950-1 cUL: CSA C22.2 No.107.1 Approved standards cUR: CSA No.60950-1 EN/VDE: EN50178 (= VDE0160) According to VDE 0106/P100, IP20 (except terminal block) SEMI F47-0200 (200-VAC input) Weight 330 g max. 490 g max. *1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. *2. Refer to Engineering Data (60-W, 90-W, 120-W, 180-W, and 240-W Models) on page 7 for details. *3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. *4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. 2