DQ (ADQ) 1a 30A polarized DQ RELAYS (ADQ) power relays FEATURES TYPICAL APPLICATIONS 1. 30A capacity in small size 1. Time switches 2. Contributes to device energy 2. Electric water heaters savings with latching type. 3. Remote control of electric power 3. High insulation meters 4,000V AC (between contacts and coil) Surge 10,000V (between contacts and coil) 4. Cd-free, Pb-free 5. Sealed construction RoHS compliant 6. UL/C-UL approved ORDERING INFORMATION ADQ 3 Q 0 Operating function 1: 1 coil latching (1 Form A) 2: 2 coil latching (1 Form A) Contact capacity 3: 30 A Terminal shape Q: 250 Faston terminal Contact characteristics 0: Standard contact Nominal coil voltage (DC) 4H: 4.5 V, 06: 6 V, 09: 9 V, 12: 12 V, 24: 24 V TYPES Part No. Contact Nominal coil arrangement voltage 1 coil latching 2 coil latching 4.5V DC ADQ13Q04H ADQ23Q04H 6V DC ADQ13Q006 ADQ23Q006 1 Form A 9V DC ADQ13Q009 ADQ23Q009 12V DC ADQ13Q012 ADQ23Q012 24V DC ADQ13Q024 ADQ23Q024 Standard packing: Carton: 20 pcs. Case: 200 pcs. RATING 1. Coil data 1) 1 coil latching Nominal operating Nominal coil Set voltage* Reset voltage* Coil resistance Nominal operating Max. applied voltage current voltage (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) power (at 20C 68F) 10% (at 20C 68F) 4.5V DC 111.1mA 40.5 6V DC 83.3mA 72 70%V or less of 70%V or less of 130%V of 9V DC nominal voltage nominal voltage 55.6mA 162 500mW nominal voltage (Initial) (Initial) 12V DC 41.7mA 288 24V DC 20.8mA 1,152 * Pulse, direction of measurement: Terminal is downward. ASCTB178E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/DQ (ADQ) 2) 2 coil latching Nominal operating Coil resistance Nominal operating current Nominal coil Set voltage* Reset voltage* Max. applied voltage 10% (at 20C 68F) power 10% (at 20C 68F) voltage (at 20C 68F) (at 20C 68F) (at 20C 68F) Set coil Reset coil Set coil Reset coil Set coil Reset coil 4.5V DC 221.7mA 221.7mA 20.3 20.3 6V DC 166.7mA 166.7mA 36 36 70%V or less of 70%V or less of 130%V of 9V DC nominal voltage nominal voltage 111.1mA 111.1mA 81 81 1,000mW 1,000mW nominal voltage (Initial) (Initial) 12V DC 83.3mA 83.3mA 144 144 24V DC 41.7mA 41.7mA 576 576 * Pulse, direction of measurement: Terminal is downward. 2. Specications Characteristics Item Specications Arrangement 1 Form A Contact Contact resistance (Initial) Max. 30 m (By voltage drop 6 V DC 1A) Contact material AgSnO2 type Nominal switching capacity (resistive load) 30 A 250V AC Max. switching power (resistive load) 7,500 V A Max. switching voltage 250V AC Rating Max. switching current 30 A Nominal operating power 500mW (1 coil latching), 1,000mW (2 coil latching) 1 Min. switching capacity (Reference value)* 100mA 5 V DC Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as Breakdown voltage section. Between open contacts 1,500 Vrms for 1min. (Detection current: 10mA.) Breakdown voltage (Initial) Between contact and coil 4,000 Vrms for 1min. (Detection current: 10mA.) Electrical Surge breakdown Between contact and coil Min. 10,000 V 2 characteristics voltage* (Initial) Temperature rise (at 65C 149F) (coil) Max. 50C (By resistive method, max. switching current) (Coil de-energized) Set time (at 20C 68F) Max. 20 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) Reset time (at 20C 68F) Max. 20 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) 2 Functional Min. 200 m/s (Half-wave pulse of sine wave: 11 ms detection time: 10s.) Shock resistance 2 Destructive Min. 1,000 m/s (Half-wave pulse of sine wave: 6 ms.) Mechanical characteristics Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 2 mm 6 Mechanical Min. 10 (at 180 times/min.) Expected life 4 Electrical Min. 10 (At nominal switching capacity, operating frequency: 3s ON, 3s OFF) Ambient temperature: 40C to +65C 40F to +149F 3 Conditions for operation, transport and storage* Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Conditions Max. operating speed 10 times/min. (at rated load) Unit weight Approx. 35 g 1.23 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. ASCTB178E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/