GU Form A & B (AQW614) Both NO and NC contacts incorporated in a GU Form A & B DIP8-pin package (AQW614) AQW614 FEATURES TYPICAL APPLICATIONS 6.4 9.78 .252 .385 1. Approx. 1/2 the space compared High-speed inspection machines 3.9 with the mounting of a set of Telephone equipment .154 1 Form A and 1 Form B PhotoMOS Computers 6.4 relays Sensing equipment .252 9.78 .385 2. Applicable for 1 Form A 1 Form B 3.6 .142 use as well as two independent 1 Form A and 1 Form B use 3. Controls load currents up to 0.13 A CAD DataCAD Data with 5 mA input current mm inch 4. Extremely low closed-circuit offset voltages to enable control of small 1 8 analog signals without distortion N.C. 5. Stable on-resistance 2 7 3 6 4 5 N.O. TYPES Output rating* Part No. Packing quantity Through hole Surface-mount terminal terminal Package Load Load Tape and reel packing style voltage current Tube packing style Tube Tape and reel Picked from the Picked from the 1/2/3-pin side 4/5/6-pin side 1 tube contains: AC/DC 50 pcs. 400 V 100 mA DIP8-pin AQW614 AQW614A AQW614AX AQW614AZ 1,000 pcs. dual use 1 batch contains: 500 pcs. *Indicate the peak AC and DC values. Note: The surface mount terminal shape indicator A and the packing style indicator X or Z are not marked on the relay. RATING 1. Absolute maximum ratings (Ambient temperature: 25C 77 F) Item Symbol AQW614(A) Remarks LED forward current IF 50 mA LED reverse voltage VR 5 V Input Peak forward current IFP 1 A f = 100 Hz, Duty factor = 0.1% Power dissipation Pin 75 mW Load voltage (peak AC) VL 400 V Peak AC, DC Continuous load current IL 0.1 A (0.13 A) ( ): in case of using only 1a or 1b, Output 1 channel Peak load current Ipeak 0.3 A 100 ms (1 shot), VL = DC Power dissipation Pout 800 mW Total power dissipation PT 850 mW Between input and output/between I/O isolation voltage Viso 1,500 V AC contact sets Operating Topr 40 C to +85 C 40F to +185F Non-condensing at low temperatures Temperature limits Storage Tstg 40 C to +100 C 40 F to +212F ds x615 en aqw614: 011212J 1GU Form A & B (AQW614) 2. Electrical characteristics (Ambient temperature: 25 C 77 F) Item Symbol AQW614(A) Condition Typical 0.9 mA IFon (N.O.) LED operate current IL = 100 mA IFoff (N.C.) Maximum 3 mA Minimum 0.4 mA IFoff (N.O.) Input LED reverse current IL = 100 mA IFon (N.C.) Typical 0.8 mA Typical 1.25 V (1.14 V at IF = 5 mA) LED dropout voltage VF IF = 50 mA Maximum 1.5 V IF = 5 mA (N.O.) Typical 27 IF = 0 mA (N.C.) On resistance Ron IL = 100 mA Maximum 50 within 1 s on time Output IF = 0 mA (N.O.) Off state leakage current Maximum ILeak 1 A IF = 5 mA (N.C.) VL = 400 V Typical 0.28 ms (N.O.) 0.43 ms (N.C.) Ton (N.O.) IF = 0 mA 5 mA Operate time* Toff (N.C.) IL = 100 mA Maximum 1 ms Typical 0.04 ms (N.O.) 0.3 ms (N.C.) Toff (N.O.) IF = 5 mA 0 mA Reverse time* Transfer Ton (N.C.) IL = 100 mA Maximum 1 ms characteristics Typical 0.8 pF f = 1 MHz I/O capacitance Ciso VB = 0 V Maximum 1.5 pF Initial I/O isolation resistance Minimum Riso 1,000 M 500 V DC *Operate/Reverse time 1) N.O. 2) N.C. Input Input 90% Output Output 10% 10% 90% Ton Toff Toff Ton RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper relay operation and resetting. Item Symbol Recommended value Unit Input LED current IF 5mA Dimensions Schematic and Wiring Diagrams Cautions for Use These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic technical representative. Please refer to our information on PhotoMOS Relays for Automotive Applications. REFERENCE DATA 1. Load current vs. ambient temperature 2. On resistance vs. ambient temperature 3. Operate time vs. ambient temperature characteristics characteristics characteristics Allowable ambient temperature: 40 C to +85C Measured portion: between terminals 5 and 6, 7 and 8 LED current: 5 mA 40 F to +185F LED current: 5 mA Load voltage: 400 V (DC) Load voltage: 400 V (DC) Continuous load current: 100 mA (DC) Continuous load current: 100 mA (DC) 140 60 1.2 Using only 1 channel Between terminal 5 and 6 (N.O.) Between terminal 5 and 6 (N.O.) Between terminal 7 and 8 (N.C.) Between terminal 7 and 8 (N.C.) 120 50 1.0 Using 2 channels 100 40 0.8 80 30 0.6 60 20 0.4 40 10 0.2 20 0 0 0 -40 -20 0 2040608085 -40 -20 0 204060 8085 -40 -20 0 204060 8085100 Ambient temperature, C Ambient temperature, C Ambient temperature, C 2 ds x615 en aqw614: 011212J Load current, mA On resistance, Operate (OFF) time, ms