WWW.PHIHONG.COM 75W Power over Ethernet Adapter Ultra Power over Ethernet Single Port Injector Features Diagnostic LEDs Gigabit Compatible Full Protection OCP, OVP Broken Wire Detection 1 Year Warranty Class 4 Operation 25K only on Data Pairs 3,6,1,2 for Single Source 4 Pair Power Current Detection for Full Power Sharing Not IEEE BT Compliant Applications Satellite Receiver Security Cameras Wireless Network Access Points Kiosks LCD Displays Computer Workstations Safety Approvals cUL/UL CE Mechanical Characteristics Length: 166mm (6.53in) Height: 44mm (1.73in) Width: 80mm (3.15in) Weight: 0.5Kg Output Specifications DC Output Load Regulation Model 1 Voltage Min. Max. Line Load 2 POE75U-1UP(PD) 56V 0A 0.67A 54-57V DC under all conditions Notes 1. Load per output. Output on spare pairs and data pairs is 0.67A for a combined output current of 1.34A. 2. Consult factory for availability Reference files: 1. SNMPv2c User Manual-Rev1.7.pdf 2. SNMPv2c Firmware-Rev1.7.zip 3. SNMPv2c MIB 10 30 2009.zip Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for the most up-to-date specifications and contact information. Revision 12/11/2018 POE75U-1UP-PD Characteristics WWW.PHIHONG.COM INPUT: EMC AC Input Voltage Range Complies with FCC Class B 90 to 264VAC Complies with EN55032 Class B AC Input Voltage Rating Isolation Test 100 to 240VAC, 47-63Hz Primary to Secondary: 4242VDC for 1 min10mA AC Input Current Primary to Field Ground: 2121VDC for 1 2.0A (RMS) max for 90VAC min 1.2A (RMS) max for 240VAC Output to Field Ground: 2121VDC Leakage Current Immunity 3.5mA max 254VAC 60Hz ESD: EN61000-4-2. Level 3 RS: EN61000-4-3. Level 3 AC Inrush Current EFT: EN61000-4-4. Level 2 30A (RMS) max for 115VAC Surge: EN61000-4-5. Level 3 60A (RMS) max for 230VAC CS: EN61000-4-6. Level 2 Voltage Dips EN61000-4-11 OUTPUT: Harmonic: EN61000-3-2 Class A Total Output Power 75W Insulation Resistance Primary to Secondary: >10M OHM Ripple and Regulation 500VDC 250mV max Primary to Field Ground: >10M OHM 500VDC DC Offset No data degradation with DC imbalance Detection 18mA per min. Requires 25K detection on data pairs 3,6(+) 1,2(-) for full power 75W Efficiency 80% (typical) at max load, 120VAC 60Hz FEATURES: Over Voltage/Current, Short Circuit Hold-up Time Protection 10mS min. 120VAC and max load The output can be shorted permanently without damage. Transient O/P Voltage Protection 60V max Indicators ENVIRONMENTAL: Green LED 1: DC Power OK Temperature Red LED: Fault detected Operation -20 to +40C Green LED 2: Power detected CONNECT Non-operation -25 to +65C at 75W Humidity 5 to 90%