D E L C Y C E R E B PS-12350 12 Volt 35.0 AH Features A bsorbent Glass Mat (AGM) technology for superior performance Valve regulated, spill proof construction allows safe operation in any position P ower/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Integrated ABS carrying handles for ease of movement Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified U.L. recognized under file number MH 20845 Terminals (mm) Performance Specifications NB3 6 16.5 Nominal Voltage ........................................................................ 12 volts (6 cells) NB3: Heavy duty terminal posts Nominal Capacity 6 16 with nut and bolt 20-hr. (1.75A to 10.50 volts) .......................................................... 35.0 AH fasteners Torque: 3.9~5.4 Nxm 10-hr. (3.3A to 10.50 volts) ............................................................ 33.0 AH T6: Threaded insert T6 16 5-hr. (6.2A to 10.20 volts) ............................................................. 31.0 AH w. 6 mm stud M6 1-hr. (25A to 9.00 volts) ............................................................... 25.0 AH fastener 6 15-min. (70A to 9.00 volts) .................................................................. 17.5 AH Physical Dimensions: in (mm) Approximate Weight ...................................................... 24.70 lbs. (11.20 kg) Energy Density (20-hr. rate) .............................. 1.70 W-h/in3 (103.84 W-h/l) Specific Energy (20-hr. rate) ............................... 17.00 W-h/lb (37.49 W-h/kg) Internal Resistance (approx.) ........................................................ 8 milliohms W Max Discharge Current (7 Min.) ............................................. 105.0 amperes Max Short-Duration Discharge Current (10 Sec.) ................ 350.0 amperes Shelf Life (% of nominal capacity at 68F (20C)) 1 Month ...................................................................................................... 97% Sealed Rechargeable Battery 3 Months ..................................................................................................... 91% HT H MODEL PS-12350 NB 6 Months .................................................................................................... 83% 12 Volt 35.0 Amp. Hr. Pb MH20845 www.power-sonic.com NONSPILLABLE Operating Temperature Range Charge .. ........................................................... -4F (-20C) to 122F (50C) L Discharge ....................................................... -40F (-40C) to 140F (60C) L: 7.72 (196) W: 5.14 (131) H: 6.22 (158) HT: 7.00 (176) Case ...................................................................................................... ABS Plastic Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for Power-Sonic Chargers ............................................PSC-124000A, 124000A-C height dimensions. All data subject to change without notice. To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. www.power-sonic.com All data subject to change without notice. T S U M Y R E T 7 T A BPS-12350 12 Volt 35.0 AH Constant Power Discharge Ratings WATTS PER CELL 25 C FINAL MODEL VOLTAGE 5 MIN 10 MIN 15 MIN 20 MIN 30 MIN 45 MIN 60 MIN 1.75 245 170 133 108 80 60 45 PS-12350 1.70 251 174 136 110 82 61 47 1.67 258 176 139 113 83 62 48 Discharge Time vs. Discharge Current Discharge Characteristics 14.0 o o Ambient Temperature 20 C (68 F) 20 13.0 15 10 12.0 5 Final 11.0 Voltage 10.5V 2 1.75 3.5 10.0 10.2V 7.0 17.5 1 9.0 Final 35 9.6V Voltage 30 8.0 70 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 9.0V o o 40 C (104 F) 10 o o min h 20 C (68 F) o o 0 C (32 F) Discharge Time 5 8.1V 1.75 3.5 7.0 17.5 35 70 Shelf Life & Storage Discharge Current (A) 100 Charging is not necessary unless 100% of capacity is required. Charging 80 o Charging before 5 C Cycle Applications: Limit initial current to 10.5A. Charge until battery voltage use is necessary o (41 F) to help recover (under charge) reaches 14.4 to 14.7 volts at 68F (20C). Hold at 14.4 to 14.7 full capacity. volts until current drops to under 350mA. Battery is fully charged under these 60 conditions, and charger should be disconnected or switched to float voltage. Charge may fail to restore full o o o 30 C 40 C 20 C capacity. Do not o o o Float or Stand-By Service: Hold battery across constant voltage source of let batteries reach (86 F) 40 (104 F) (68 F) this state. 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. 0 0 2 4 6 8 10 12 14 16 18 20 Note: Due to the self-discharge characteristics of this type of battery, it is Standing Period (Months) imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for C-Series downloads, such as product catalogs, material safety data sheets (MSDS), ISO Switch Mode Chargers and Transformer Type A and F Series. Please contact our certification, etc.. Technical department for advice if you have difficulty in locating suitable models. www.power-sonic.com Contact Information INTERNATIONAL SALES DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT Tel: +1-650-364-5001 Tel: +1-619-661-2020 Tel: +1-619-661-2030 Tel: +1-619-661-2020 Fax: +1-650-366-3662 Fax: +1-619-661-3650 Fax: +1-619-661-3648 Fax: +1-619-661-3648 international-sales power-sonic.com national-sales power-sonic.com customer-service power-sonic.com support power-sonic.com CORPORATE OFFICE 7550 Panasonic Way San Diego, CA 92154 USA Tel: +1-619-661-2020 Fax: +1-619-661-3650 0812 1M 2012. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. Discharge Time min h Terminal Voltage (V) Capacity Retention Ratio (%)