POWER MATE TECHNOLOGY FDC40 SERIES 40 WATTS OUTPUT POWER 2:1 WIDE INPUT VOLTAGE RANGE DESIGN MEET SAFETY STANDARD SIX-SIDED CONTINUOUS SHIELD HIGH EFFICIENCY UP TO 90% STANDARD 3 X 2.6 X 0.4 PACKAGE FIXED SWITCHING FREQUENCY The FDC40 series offer 40 Watts of output power from a 3 x 2.6 x 0.4 inch package. The FDC40 series have 2:1 wide input voltage of 9-18, 18-36 and 36-75VDC. The FDC40 features 1600VDC of isolation, short-circuit and over-voltage protection, as well as six sided shielding. Designed meets the safety of EN60950-1 and UL60950-1. All models are particularly suited to telecommunications, industrial, mobile telecom and test equipment applications. T E C H N I C A L S P E C I F I C AT I O N All specifications are typical at nominal input, full load and 25C otherwise noted OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Output power 40 Watts, max. Efficiency See table Single & Dual 2% Input to Output 1600VDC, min. Isolation voltage Voltage accuracy Full load and nominal Vin Triple 3.3V/5V 2% Input(Output)to Case 1000VDC, min. Auxiliary 5% 9 Isolation resistance 10 ohms, min. Voltage adjustability (Note 5: only for single output) 10% Isolation capacitance 500Pf, max. FDC40-XXD3305 3.3V output 20% min. Minimum load (Note 6) Switching frequency 185KHz, typ. Others 10% of FL Single 0.5% Design meet safety standard IEC60950-1, UL60950-1, EN60950-1 Dual 1% Line regulation LL to HL at Full Load Triple 3.3V/5V 2% Case material Nickel-coated copper Auxiliary 5% Base material FR4 PCB Single 0.5% Dual 1% Load regulation 10% to 100% FL Potting material Epoxy (UL94-V0) Triple 3.3V/5V 2% 3.03 X 2.62 X 0.40 Inch Auxiliary 5% Dimensions (77.0 X 66.5 X 10.2 mm) Dual 1% Cross regulation (Note 7) Triple 3.3V/5V 1% Weight 125g (4.4oz) Auxiliary 5% 6 MTBF (Note 1) 1.590 x 10 hrs 20MHz bandwidth Ripple and noise See table (Measured with a 104pF/50V MLCC) ENVIRONMENTAL SPECIFICATIONS Temperature coefficient 0.02% / C, max. Operating ambient temperature -40C ~ +85C (with derating) Transient response recovery time 25% load step change 500S 3.3V output 3.9VDC Maximum case temperature +100C Over voltage protection 5V output 6.2VDC Storage temperature range -55C ~ +105C Zener diode clamp 12V output 15VDC 15V output 18VDC Nature convection 7.28C/Watt Thermal impedance 500LFM 1.62C/Watt Over load protection % of FL at nominal input 150%, max. Thermal shock MIL-STD-810F Short circuit protection Hiccup, automatics recovery Vibration MIL-STD-810F INPUT SPECIFICATIONS Relative humidity 5% to 95% RH 12V nominal input 9 18VDC Input voltage range 24V nominal input 18 36VDC EMC CHARACTERISTICS 48V nominal input 36 75VDC Input filter Pi type Conducted emissions EN55022 Class A 12V input 36VDC Input surge voltage Radiated emissions EN55022 Class A 24V input 50VDC 100mS max 48V input 100VDC ESD EN61000-4-2 Perf. Criteria B Input reflected ripple(Note 8) Nominal Vin and full load 40mAp-p Radiated immunity EN61000-4-3 Perf. Criteria A Nominal Vin and Powe up 25mS, typ. Start up time constant resistive load Remote ON/OFF 25mS, typ. Fast transient EN61000-4-4 Perf. Criteria B Remote ON/OFF Surge EN61000-4-5 Perf. Criteria B (Note 9) DC-DC ON Open or 3.5V < Vr < 12V DC-DC OFF Short or 0V < Vr < 1.2V Conducted immunity EN61000-4-6 Perf. Criteria A Remote off input current Nominal input 30mA For more information 1 800 280 2839 www.norgay.comPOWER MATE TECHNOLOGY FDC40 SERIES (3) (4) Model Input Output Output Output Input Eff Capacitor (2) Number Range Voltage Current Ripple & Noise Current (%) Load max FDC40-12S33 9 18 VDC 3.3 VDC 10000mA 50mVp-p 82 25800F 3530mA FDC40-12S05 9 18 VDC 5 VDC 8000mA 85 13600F 50mVp-p 4120mA FDC40-12S12 9 18 VDC 12 VDC 3400mA 120mVp-p 4150mA 86 2400F FDC40-12S15 9 18 VDC 15 VDC 2700mA 150mVp-p 4120mA 86 1550F FDC40-12D05 9 18 VDC 5 VDC +7000 / -1000mA 75mVp-p 4330mA 81 12000 / 1700F FDC40-12D12 9 18 VDC 12 VDC 1800mA 120mVp-p 4550mA 83 1200F FDC40-12D15 9 18 VDC 15 VDC 1400mA 150mVp-p 4430mA 83 750F FDC40-12D3305 9 18 VDC 3.3 / 5VDC 4000 / 4000mA 75mVp-p 3730mA 78 10300 / 6800F FDC40-12T0512 9 18 VDC 5 / 12 VDC 4000 / 850mA 50 / 120mVp-p 4490mA 79 6800 / 590F FDC40-12T0515 9 18 VDC 5 / 15 VDC 4000 / 680mA 50 / 150mVp-p 4430mA 80 6800 / 380F FDC40-24S33 18 36 VDC 3.3 VDC 10000mA 50mVp-p 1660mA 87 25800F FDC40-24S05 18 36 VDC 5 VDC 8000mA 50mVp-p 1990mA 88 13600F FDC40-24S12 18 36 VDC 12 VDC 3400mA 120mVp-p 2000mA 89 2400F FDC40-24S15 18 36 VDC 15 VDC 2700mA 150mVp-p 1990mA 89 1550F FDC40-24D05 18 36 VDC 5 VDC +7000 / -1000mA 75mVp-p 2160mA 81 12000 / 1700F FDC40-24D12 18 36 VDC 12 VDC 1800mA 120mVp-p 2200mA 86 1200F FDC40-24D15 18 36 VDC 15 VDC 1400mA 150mVp-p 2140mA 86 750F FDC40-24D3305 18 36 VDC 3.3 / 5VDC 4000 / 4000mA 75mVp-p 1840mA 79 10300 / 6800F FDC40-24T0512 18 36 VDC 5 / 12 VDC 4000 / 850mA 50 / 120mVp-p 2220mA 80 6800 / 590F FDC40-24T0515 18 36 VDC 5 / 15 VDC 4000 / 680mA 50 / 150mVp-p 2160mA 82 6800 / 380F FDC40-48S33 36 75 VDC 3.3 VDC 10000mA 50mVp-p 850mA 85 25800F FDC40-48S05 36 75 VDC 5 VDC 8000mA 50mVp-p 980mA 89 13600F FDC40-48S12 36 75 VDC 12 VDC 3400mA 120mVp-p 1000mA 89 2400F FDC40-48S15 36 75 VDC 15 VDC 2700mA 150mVp-p 1000mA 88 1550F FDC40-48D05 36 75 VDC 5 VDC +7000 / -1000mA 75mVp-p 1060mA 84 12000 / 1700F FDC40-48D12 36 75 VDC 12 VDC 1800mA 120mVp-p 1100mA 86 1200F FDC40-48D15 36 75 VDC 15 VDC 1400mA 150mVp-p 1070mA 86 750F FDC40-48D3305 36 75 VDC 3.3 / 5VDC 4000 / 4000mA 75mVp-p 910mA 80 10300 / 6800F FDC40-48T0512 36 75 VDC 5 / 12 VDC 4000 / 850mA 50 / 120mVp-p 1060mA 83 6800 / 590F FDC40-48T0515 36 75 VDC 5 / 15 VDC 4000 / 680mA 50 / 150mVp-p 1060mA 83 6800 / 380F Note 1. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40C. (Ground fixed and controlled environment) 2. Maximum value at nominal input voltage and full load 3. Typical value at nominal input voltage and full load 4. Test by minimum Vin and constant resistive load. 5. Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +Vsense should be connected to its corresponding +OUTPUT and likewise the FDC40-48S05 sense should be connected to its corresponding OUTPUT. Efficiency VS Input Voltage 6. The FDC40 series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they 90 may not meet all listed specification. 89 88 7. Cross regulation: 87 Dual outputAsymmetrical load 25% to 100% full load 86 Triple output 3.3V / 5V 100% load and one of auxiliary 100% load, other 85 auxiliary load change from 25% to 100% load 84 8. Please add an external filter at converter input terminals when measuring input reflected ripple, 83 82 as Figure 1. 81 L : Simulated source impedance of 12H. 80 C: Nippon chemi-con KY series, 220F/100V 36 40 45 50 55 60 65 70 75 9. The ON-OFF control pin voltage is reference to negative input. INPUT VOLTAGE (V) FDC40-48S05 Derating Curve FDC40-48S05 Efficiency VS Output load 100 90 89 88 75 86 Nature convection 84 50 82 500LFM 80 25 70 60 50 0 45 -40 -25 -10 100 0 50 60 70 80 90 0.5 1 2 3 4 5 6 7 8 AMBIENT TEMPERATURE (C) OUTPUT LOAD (A) For more information 1 800 280 2839 www.norgay.com OUTPUT POWER (%) EFFICIENCY (%) EFFICIENCY (%)