Raspberry Pi B+ Power Supply Australian Plug Specifications: Input Characteristics: Rated Voltage :100-240V AC Variation Range : 90-264V AC Rated Frequency : 50/60Hz Variation Frequency : 47-63Hz Input Current : 0.5A max at any input voltage and rated, DC output rated load. Inrush Current : 50A max. Cold start at 220V AC input, with rated load and 25 ambient. AC Leakage Current : 0.25mA Max. at 240V AC input No-load input power : When the no-load output, 230V AC input, the input power 0.3W Max. Output Characteristics: Power output Voltage Min. Load Rated. Load Peak Output Power 5V DC 0.01A 2A - 10W Combined Load/Line Regulation Voltage Min. Load Rated. Load Voltage range Load Regulation 5V DC 0.01A 2A 4.75 to 5.25V DC 5% Ripple and Noise Under rated voltage and rated load, the ripple and noise are as follows when measure with Max. Band width of 20MHz and Parallel 10F/0.1F,crossed connected at testing point. Voltage Ripple and Noise (Max.) 5V DC 80mV p-p Turn on delay time : 3 seconds Max. at 115V AC input and output Max. load Rise time : 10ms Max. at 115V AC input and output Max load Hold up time : 5ms Min. at 115V AC input and output Max. load Efficiency : 75% Min. at 115V AC input and output Max. load : 75% Min. at 230V AC input and output Max. load www.element14.com www.farnell.com www.newark.com www.cpc.co.uk Page <1> 02/09/14 V1.0Raspberry Pi B+ Power Supply Australian Plug Protection Requirement: Short circuit protection : The power supply will be auto recovered when short circuit faults remove Over Current Protection : When adjusted to 3.5A output current. Automatic Protection Over Voltage Protection : The power supply will auto recovered when faults remove 150% to 180% Environmental Requirement: Operating Temperature : 0C to 40C / Full load, Normal operation Storage Temperature : -10C to 80C Part Number Table Dimensions : Millimetres Description Part Number Powersupply, USB, 5V, 2A, Aus PSU-RASPBERRY-PI-2A-5V Important Notice : This data sheet and its contents (the Information) belong to the members of the Premier Farnell group of companies (the Group) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Groups liability for death or personal injury resulting from its negligence. pro - POWER is the registered trademark of the Group. Premier Farnell plc 2012. www.element14.com www.farnell.com www.newark.com www.cpc.co.uk Page <2> 02/09/14 V1.0