6W Class II AC-DC LED power supply Features 350mA, 500mA and 700mA CC/CV output AC/DC Converter Fused input and SCP, OVP, OLP, OTP 3kVAC isolation LED Universal input voltage range Driver Low cost RACD06 Description 6 Watt A compact universal input 6W constant current switching power module suitable for driving up to 12 high power LEDs.The output (dual constant voltage / constant current mode) current limit is fixed at CC/CV 350mA, 500mA or 700mA. At lower output currents, the output is constant voltage. Single Output Selection Guide Part Input CC CV Efficiency Rated (1) Number Voltage Range Mode Mode typ. Power nom./max. VAC VDC mA VDC mA % W RACD06-350 90-264 3-22 350 24 0-300 79 6 / 7.2 RACD06-500 90-264 3-12 500 none 70 6 RACD06-700 90-264 3-8.4 700 12 0-600 72 6 / 7.2 All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime. Model Numbering E340696 RACD06- nom. Output Power nom. Output Current Specifications (measured Ta= 25C, nom. Vin, rated load and after warm-up unless otherwise stated) UL8750 certified BASIC CHARACTERISTICS UL1310 certified Parameter Condition Min. Typ. Max. CAN/CSA-C22.2 No. 223-M91 certified 90VAC 230VAC 264VAC IEC/EN61347 certified Input Voltage Range IEC/EN61347-2-13 certified 120VDC 370VDC ENEC certified Input Current full load, 100VAC 200mA PSE certified Inrush Current 115VAC/230VAC, <2ms 10A CB Report 350mA 26VDC Open Circuit Voltage no load 500mA 17VDC 700mA 14VDC Input Frequency Range 47Hz 63Hz 115VAC 0.40 Power Factor full load 230VAC 0.55 Hold-up Time 18ms Output Ripple Current 200mAp-p continued on next page www.recom-power.com REV.: 1/2019 L-1700mA 600mA 500mA 350mA 300mA RACD06 AC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, rated load and after warm-up unless otherwise stated) (1) Constant Current (CC) and Constant Voltage (CV) CV RACD06-350 24V RACD06-500 22V RACD06-700 12V CV 12V 8.4V CC CC CC 3V Output Current Nominal Current Limits Notes: Note1: CV Mode is approved by Recom internal quality standard, but not certified PROTECTION Parameter Condition Value Input Fuse T2A, slow blow Short Circuit Protection (SCP) continuous, current limit Overload Protection (OLP) 120% typ. Over Temperature Protection (OTP) shutdown, automatic resatart after cooling down Isolation Voltage I/P to O/P 3.75kVAC / 1 minute Notes: Note2: Refer to local safety regulations if input over-current protection is also required Maximum loading of automatic circuit breakers* * 115VAC, 1Ohm, 90 phase angle and max. load * 230VAC, 1Ohm, 90 phase angle and max. load Circuit Breaker Circuit Breaker Current Circuit Breaker Circuit Breaker Current Typ 10A 16A 20A 25A Typ 10A 16A 20A 25A B 80 157 200 254 C 221 247 337 430 C 265 317 437 550 ENVIRONMENTAL Parameter Condition Value according to UL RACD06-350 -20C to +50C Operating Temperature Range RACD06-500, RACD06-700 -20C to +40C according to ENEC all -20C to +50C according to UL RACD06-350 +75C max. Max. Case Temperature RACD06-500, RACD06-700 +70C max. according to ENEC all +70C max. IP Rating IP20 Operating Humidity non condensing 5%-85% RH 3 Design Lifetime +25C ambient 20 x 10 hours continued on next page www.recom-power.com REV.: 1/2019 L-2 Output Voltage