Universal AC Input Features Constant Voltage / Constant Current Operation LIGHTLINE CE and UL Certified Class I LED Driver LED DRIVER Active Power Factor Correction AC/DC-Converter IP67 Design for Indoor and Outdoor Use with 5 year Warranty Cooling by Free Air Convection Selection Guide Part CV Mode CC Mode Efficiency Number Constant Voltage Current Range DC Voltage Range Constant Current (230VAC) (V) (A) (V) (A) (%) 100 Watt RACD100-12 12 0-8.3 9-12 8.3 88 RACD100-24 24 0-4.2 14-24 4.2 90 Single RACD100-36 36 0-2.8 26-36 2.8 90 RACD100-48 48 0-2.1 34-48 2.1 91 Output Specifications Input Voltage Range 90-305 VAC or 127-430VDC Input Frequency Range 47-63Hz. Power Factor Full Load, 115VAC >0.98 Full Load, 230VAC >0.95 Full Load, 277VAC >0.94 THD Full Load, 115VAC 8% max. RoHS AC Current 115VAC 1.4A max. 2011/65/EU 6/6 230VAC 0.7A max. Input/Output Isolation 3.75kVAC / 1minute Input/Case Isolation 1.8kVAC / 1minute E340696 Output/Case Isolation 0.5kVAC / 1minute UL 8750 Certified Leakage Current 240VAC <0.75mA EN 61347 Certified Voltage Tolerance -1% to 5% Start-up Time 115VAC 1.5s ( Full Load) 230VAC / 277VAC 0.7s Ripple & Noise 48V Version 200mV max. RACD100 others 150mV max. Over Current Protection 95%-105% rated current Auto-Recovery Short Circuit Protection Hiccup Mode Over Voltage Protection 12V 15V typ. Latch Mode 24V 31V typ. (Power off to recover) 36V 45V typ. 48V 58V typ. Over Temperature Protection Tcase 95C 10C Operating Temperature Range without derating -20C to +50C (see graph) (free air convection, according to CE/UL) Case Temperature 90C max. Note: Operation Humidity 20%-90% RH Non-Condensing All LED Drivers may not be used without a load. Storage Temperature -40C to +80C They must be switched on the primary side Storage Humidity 10%-90% RH only. Noncompliance may damage the LED or Vibration 10-500Hz, 2G, 60 Min. along X, Y and Z reduce its lifetime. IP Rating IP67 Safety Standards UL/cUL LED Lighting Safety (E340696) UL8750 CE LVD Directive, Safety EN61347-2-13 CB Report: 12CA61289-1 IEC61347-2-13 EMC Standards EMC Compatibility EN55015 FCC, Part 15 Harmonic Current EN61000-3-2 Class C (75% load) EN61000-3-3 EMC Immunity EN61000-4-2, 3, 4, 5, 6, 11 Refer to Application Notes continued on next page L-56 REV: 1/2015 www.recom-power.comRACD100 RACD100 LIGHTLINE AC/DC-Converter Series Specifications Dimension 222*68*39mm Weight 1020g MTBF using MIL-HDBK-217F (25C) 250 x 10 hours Design Lifetime 70 x 10 hours The use of a circuit breaker with C-characteristic is recommended. Derating Curves B + A A . A . A - A - A , A , A A A 0 0 * + / 3 * . , * ) 8 2 2) - Typical Characteristics Constant Voltage / Constant Current Curve 7) 0 7) 0 , 7) 0*- 7) 0,. 2 2 2 2 2 2 2 2 , *- ,. 2 2 2 2 3 , - *, .%* ,% %. % 8 8 8 8 Maximum Number of LED drivers per circuit breakers Condition Circuit Breaker Circuit Breaker Current Typ 10A 16A 20A 25A 115VAC, 1Ohm C 7 12 14 18 90 phase angle B 6 10 12 14 230VAC, 1Ohm 90 phase angle C 13 22 24 31 B 7 11 14 17 277VAC, 1Ohm 90 phase angle C 15 25 29 36 Package Style and Pinning % %, 33% /% .%3 -.% * *,% * -) 12 7 33%- ( *,% .%3 02 4 (> ,) ) 6 4 5 : 7) 0 ) 69 4 6= 5 *+ + *+ + * * *3% The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOMs explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV: 1/2015 L-57