Low profile case (13mm height max.) Features 350mA to 700mA constant current outputs AC/DC Converter Terminal block input/output with cable clamps Fully protected (OLP, SCP, OCP, OTP) LED Low standby power, ErP conform Driver RACD12-LP Low cost Description 12 Watt These low profile constant current LED drivers have been designed for cost-sensitive applications. Constant The SELV outputs are suitable for both independently supplied or built-in power-supply LED luminaires. Their low profile design allows them to be invisibly built into furniture, discreetly mounted under shelves or integrated in space-restricted applications such as coving lighting, strip lighting or troffer lighting sys- Current Single tems. The power supplies are short circuit and overload protected and come with a full 3-year warranty. Output Selection Guide Part Input Input Output Output Efficiency Output Number Voltage Range Current Voltage Range Current typ. Power max. VAC mA VDC mA % W RACD12-350-LP 198-264 130 2-37 350 86 13W RACD12-500-LP 198-264 130 2-24 500 81 12W RACD12-700-LP 198-264 130 2-19 700 85 13W All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime. ERP compliant Specifications (measured Ta= 25C, 240VAC and rated load) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Voltage Range 198VAC 230VAC 264VAC Inrush Current 8.0A Start-up Time 500ms IEC/EN61347-1 certified Input Frequency Range 47Hz 63Hz IEC/EN61347-2-13 certified No Load Power Consumption 0.5W ENEC certified CB report Power Factor full load, 230VAC 0.55 EN55015 compliant Internal Operating Frequency full load 60kHz 140kHz (1) Output Ripple Current 50mAp-p Notes: Note1: Measured at 20MHz Bandwidth using 0.1F & 47F parallel capacitor REGULATIONS Parameter Condition Value Output Accuracy 5% max. Line Regulation 5% max. Load Regulation 5% max. www.recom-power.com REV.: 2/2019 L-1RACD12-LP AC/DC Converter Series Specifications (measured Ta= 25C, 240VAC and rated load) PROTECTION Parameter Condition Value Input Fuse external fuse is recommended T1A Open Circuit Protection (OCP) auto recovery after fault condition is removed Over Load Protection (OLP) auto recovery after fault condition is removed Over Voltage Protection (OVP) auto recovery after fault condition is removed Over Temperature Protection (OTP) 110C Tcase auto recovery after fault condition is removed Isolation Voltage I/P to O/P 3.75kVAC / 1 minute Maximum loading of automatic circuit breakers * 230VAC, 1Ohm, 90 phase angle and max. load Circuit Breaker Circuit Breaker Current Typ 10A 16A 20A 25A B 17 28 35 44 C 37 59 74 92 ENVIRONMENTAL Parameter Condition Value Operating Temperature Range -20C to +50C Maximum Case Temperature +80C Operating Altitude 2000m Operating Humidity non-condensing 5% to 85% RH IP Rating IP20 Pollution Degree PD2 Design Lifetime 30 x 10 hours Derating Graph 100 90 80 70 60 50 40 30 20 10 0 -20 -10 0 10 20 30 40 50 60 Ambient Temperature C www.recom-power.com REV.: 2/2019 L-2 Output Load %