Long 5 year warranty Features 2MOPP/250VAC Suitable for built in Class II applications AC/DC Converter Wide input voltage range (85-264VAC) Regulated Low leakage current (<75A) 5000m operation Converter RACM65 -40C to +85C operating temperature Description 65 Watt The RACM65 is a compact 3 x 2 high efficiency AC/DC power supply with 2xMOPP safety approval for medical applications. These space saving enclosed power supplies have an universal input Enclosed & voltage range (85-264VAC), 4kVAC isolation, require no minimum load and can be used at ambient temperatures of between -40C and +85C. The 5V, 12V, 15V, 24V or 48V output voltages are Open Frame fully protected and have tolerances of less than 0.2% over the entire input voltage range and less than 0.5% over the entire load range. The output voltage can be Case Style trimmed over a 10% range. The RACM65 series is certified to medical safety standard IEC/ES/EN-60601-1 3rd Edition and with less than 75A leakage current. It has a built-in Class B EMI Single Output filter and comes with a 5 year warranty. Selection Guide Part Input Output Output Efficiency Max. Capacitive (1) Number Voltage Range Voltage Current typ. Load VAC VDC A % F (1,2) RACM65-05S 85-264 5 10 90 20000 (1,2) RACM65-12S 85-264 12 5.42 92.5 4520 (1,2) RACM65-15S 85-264 15 4.34 93.5 2900 (1,2) RACM65-24S 85-264 24 2.71 93.5 1130 2MOPP 250VAC (1,2) RACM65-48S 85-264 48 1.36 93 235 Notes: Note1: Max Cap Load is tested at minimum input and full resistive load Model Numbering E314885 RACM65- S / - CSA/CAN-C22.2 No 60601-1:14 certified (3) ANSI/AAMI ES60601-1 certified Output Power Connections EN60601-1-2 (1) Output Voltage Case Style CISPR11 FCC Part 15 & 18 Single Notes: Note2: Case Style: without suffix, standard enclosed case add suffix /OF for open frame style Note3: Connections: without suffix, standard connection with connector with suffix -ST connection with screw terminals Examples: RACM65-12S = 12Vout, standard enclosed case RACM65-48S/OF = 48Vout, open frame style RACM65-15S/OF-ST = 15Vout, open frame style with screw terminal connection www.recom-power.com REV.: 7/2019 MED-1RACM65 AC/DC Converter Series Specifications (measured at Ta= 25C, 250VAC, full load and after warm-up) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. 85VAC 230VAC 264VAC Input Voltage (4) 100VDC 370VDC 115VAC, full load 1.6A Input Current 230VAC, full load 0.9A Inrush Current cold start, 230VAC 60A No load Power Consumption 0.11W (4) Input Frequency Range AC Input 50/60Hz 440Hz Output Voltage Trimming on-board trimpot 10.0% Minimum Load 0% Start-up Time 1s Rise Time 20ms Hold up Time 115VAC, full load 16ms 5VDC, 230VAC 60kHz Operating Frequency Range others, 230VAC 120kHz Output Ripple and Noise 5VDC, 12VDC and 15VDC with 10F/25V MLCC 75mVp-p (measured 20MHz BW) 24VDC, with 1F/50V MLCC 75mVp-p 48VDC, with 0.1F/100V MLCC 150mVp-p Notes: Note4: Confirmed performance, but not covered in certificates. 100V input voltage with derating RACM65-24S Efficiency vs. Load Efficiency vs. Input Voltage 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 115VAC 50% load 10 10 230VAC 100% load 0 0 10 20 30 40 50 60 70 80 90 100 85 105 125 145 165 185 205 225 245 264 Output Load % Input Voltage VAC Line Derating 100 90 80 70 60 50 40 30 20 85 105 125 145 165 185 205 225 245 264 90 Input Voltage VAC www.recom-power.com REV.: 7/2019 MED-2 Efficiency % Output Load % Efficiency %