C C S S O O R R w E E M M T T P P R R a L L R I I E E A A r V V N N A N N T T r NOT RECOMMENDED FOR NEW DESIGNS TH (LAST TIME BUY: 27 NOV 2020) Universal AC input (85-264VAC) Features Long 7 year warranty Protections: SCP, OVP, OCP, OTP AC/DC Converter 100% full load burn-in test DIN Rail DC OK indicator LED with relay contacts Cooling by free air convection, 5000m operation Series REDIN45 UL, CSA & CE certified with CB report Description 45 Watt 7 This DIN-rail mounted power supply uses high reliability components to give a long, trouble-free life. DIN-Rail The power supply can be end mounted to save space or side mounted for use in low-profile cabinets. Relay contacts simplify DC OK monitoring and the units can deliver 60W start-up power. Power Supply The REDIN45 series isv fully certified for industrial use and carries a 7-year warranty. Selection Guide Part Input Output Output Rated Efficiency Max. Number Voltage Range Voltage Trimming Voltage Current typ. Capacitive Load VAC VDC VDC A % F REDIN45-12 85-264 12 12-15 3.75 85 18800 REDIN45-24 85-264 24 24-28 1.875 86 4700 Specifications (measured at Ta= 25C, 230VAC, full load and after warm up) 22 RoHSRoHS REACHREACH compliantcompliant compliantcompliant 6 from 66 from 6 BASIC CHARACTERISTICS 2011/65/EU2011/65/EU Parameter Condition Min. Typ. Max. Input Voltage Range all operating conditions 85VAC 264VAC 300VAC E224736 max. Input Voltage max. 1 second 375VDC Output Voltage Adjustment REDIN45-12 12-15VDC (12V 5%) CB-Report (1) (Factory Setting) REDIN45-24 24-28VDC (24V 5%) UL60950-1 certified full load, 115VAC 1.35A IEC/EN60950-1 certified Input Current full load, 230VAC 0.75A CSA C22.2 No. 60950-1-07 certified UL508 certified cold start at 25C, 115VAC 40A Inrush Current CAN/CSA-C22.2 No. 107.1-01 certified cold start at 25C, 230VAC 60A EN55024 certified standard (with Relay) <1000mW EN55032 certified No Load Power Consumption /NR option (no Relay) <500mW Start up time cold start, 230VAC 500ms 1000ms SEARCHING FOR Rise time cold start, 230VAC 20ms ALTERNATIVES full load, 115VAC 20ms Hold-up time full load, 230VAC 50ms Contact RECOM Input Frequency Range 47Hz 63Hz TH (LAST TIME BUY: 27 NOV 2020) NOT RECOMMENDED FOR NEW DESIGNS REDIN45 AC/DC Converter Series Specifications (measured at = 25C, 230VAC, full load and after warm up) Ta Efficiency vs. Load REDIN45-12 REDIN45-24 100 100 90 90 80 80 70 70 60 60 50 50 85VAC 40 40 115VAC 30 30 85VAC 230VAC 115VAC 264VAC 20 20 230VAC 264VAC 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % Vadj. Derating 100 80 45W max. Vadj. 12 15 (24) (28) Output Voltage VDC REGULATION Parameter Condition Value Line Regulation 0.1% typ. / 1.0% max. Load Regulation 0.1% typ. / 1.0% max. (3) Transient Response REDIN45-12 (step load change: 1.875A - 3.75A) 5.0% typ. Dwell Time REDIN45-24 (step load change: 0.937A - 1.875A) 5.0% typ. Slew Rate 100Hz & 1kHz 50% duty 0.5A / s Notes: Note3: Transienst Response + E-CAP loading 3300F. Other specs with resistive load only PROTECTION Parameter Condition Value Input Fuse T2.5A, slow blow type Short Circuit Protection (SCP) auto-recovery after fault condition, Hiccup Mode REDIN45-12 18VDC max., shut-down latch-off o/p voltage, re-power on to recover Over Voltage Protection (OVP) REDIN45-24 35VDC max., shut-down latch-off o/p voltage, re-power on to recover Over Voltage Category OVCII Over Current Protection (OCP) 150% typ., auto-recovery after fault condition is removed Over Temperature Protection (OTP) detect on inside ambient 105C5%, shut-down latch-off o/p voltage, re-power on to recover 3.75kVAC I/P to O/P Isolation Voltage tested for 1 minute I/P to FG 1.88kVAC O/P to FG 0.5kVAC continued on next page www.recom-power.com REV.: 9/2020 PDR-2 Efficiency % Output Current % Efficiency %