Bulletin No. CUB5-D Drawing No. LP0584 Released 5/06 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL CUB5 - MINIATURE ELECTRONIC 8-DIGIT DUAL COUNTER AND RATE INDICATOR z LCD, REFLECTIVE OR GREEN/RED LED BACKLIGHTING z 0.46 (11.7 mm) HIGH DIGITS z OPTIONAL RELAY OUTPUT MODULE z OPTIONAL SERIAL COMMUNICATIONS MODULE (RS232 or RS485) z COUNT SPEEDS UP TO 20 KHz z OPERATES FROM 9 TO 28 VDC POWER SOURCE z PROGRAMMABLE SCALING FOR COUNT AND RATE z BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL z QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION) U R C L USUS LISTEDLISTED IND. CONT. EQ. z DISPLAY COLOR CHANGE CAPABILITY AT PRESET OUTPUT 51EB z NEMA 4X/IP65 SEALED FRONT BEZEL COUNTER GENERAL DESCRIPTION The CUB5 receives incoming pulses and multiplies them by the Count Scale The CUB5 provides the user the ultimate in flexibility, from its complete user Factor to obtain the desired reading for the count display. Input A accepts the programming to the optional relay output capability. The meter can be signal for the count and Input B is used for quadrature, dual counter, anti- programmed as a single or dual counter with rate indication capability. The coincidence counting, or up/down control counting. display can be toggled either manually or automatically between the selected displays. RATE The CUB5 display has 0.46 (11.7 mm) high digits. The LCD is available in The rate indicator utilizes the signal at Input A to calculate the rate value two versions, reflective (CUB5R000) and backlight (CUB5B000). The using a time interval method (1/tau). The unit counts on the negative edge of the backlight version is user selectable for green or red backlighting with variable input pulses. After the programmed minimum update time elapses and the next display intensity. negative edge occurs, the unit calculates the input rate based on the number of The counter is programmable for one of eight different count modes, edges that occurred during the elapsed time. The input rate is then multiplied by including bi-directional and quadrature. When programmed as a dual counter, the rate scaling value to calculate the rate display. each counter has a separate scale factor and decimal points. In the counter/rate At slower rates, averaging can be accomplished by programming the rate indicator mode, each have their own scaling and decimal point read-outs in minimum update time for the desired response. Extensive scaling capabilities different engineering units. allow practically any desired reading at very slow count rates. The meter has two separate inputs which provide different functions depending on which operating mode is selected. Input A accepts the signal for SAFETY SUMMARY the Count and/or Rate displays, while Input B accepts the signal for the Count display or direction control. In the anti-coincidence mode, both inputs are All safety related regulations, local codes and instructions that appear in this literature or on equipment must be observed to ensure personal safety and to monitored simultaneously so that no counts are lost. The resulting display can be chosen as the sum or difference of the two inputs. The Rate Indicator has prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection programmable low (minimum) and high (maximum) update times to provide optimal display response at any input frequency. There is a programmable user provided by the equipment may be impaired. Do not use this meter to directly command motors, valves, or other actuators input that can be programmed to perform a variety of functions. The capability of the CUB5 can be easily expanded with the addition of an not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the meter. option module. Setpoint capability is field installable with the addition of the CUB5RLY0, relay output module. Serial communications capability for RS232 or RS485 is added with a serial option module. The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor Power Supply (MLPS1000), which attaches directly to the back of a CUB5. The CAUTION: Risk of Danger. CAUTION: Risk of electric shock. MLPS1 is powered from 85 to 250 VAC and provides up to 400 mA to drive the Read complete instructions prior to unit and sensors. installationand operation of the unit. DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15 (54.6) H x 3.00 (76.2) W. 1ORDERING INFORMATION TYPE MODEL NO. DESCRIPTION PART NUMBER CUB5R Dual Counter & Rate Indicator with Reflective Display CUB5R000 CUB5 CUB5B Dual Counter & Rate Indicator with Backlight Display CUB5B000 CUB5RLY Single Relay Option Card CUB5RLY0 Optional Plug-in Cards RS485 Serial Communications Card CUB5COM1 CUB5COM RS232 Serial Communications Card CUB5COM2 MLPS1 Micro-Line Power Supply, 85 to 250 VAC MLPS1000 CBLPRO Programming Cable RS232 (RJ11-DB9) CBLPROG0 Accessories CBPRO Programming Cable RS232 (RJ11-DB9) CBPRO007 * SFCRD SFCRD200 Crimson 2 PC Configuration Software for Windows 98, ME, 2000, XP *Crimson 2 software is available for download from