Inside US: +1 (877) 432-9908 Bulletin No. PAXLCR-C Outside US: +1 (717) 767-6511 Drawing No. LP0749 www.redlion.net Released 2018-01-16 Model PAXLCR - PAX Lite Dual Counter and Rate Meter 6 DIGIT, 0.56 HIGH RED LED DISPLAY PROGRAMMABLE SCALING FOR COUNT AND RATE BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION) BUILT-IN BATCH COUNTING CAPABILITY PROGRAMMABLE USER INPUT DUAL 5 AMP FORM C RELAYS UNIVERSALLY POWERED NEMA 4X/IP65 SEALED FRONT BEZEL U C R L US LISTED PROC. CONT. EQ. E179259 For Model No. PAXLCRU0 Only GENERAL DESCRIPTION SAFETY SUMMARY The PAXLCR is a versatile meter that provides a single or dual counter All safety regulations, local codes and instructions that appear in this with rate indication, scaling and dual relay outputs. The 6-digit display and corresponding literature, or on equipment, must be observed to has 0.56 high digits with adjustable display intensity. The display can be ensure personal safety and to prevent damage to either the instrument or toggled manually or automatically between the selected counter and rate equipment connected to it. If equipment is used in a manner not specified values. by the manufacturer, the protection provided by the equipment may be The meter has two signal inputs and a choice of eight different count impaired. Do not use this meter to directly command motors, valves, or modes. These include bi-directional, quadrature and anti-coincidence other actuators not equipped with safeguards. To do so can be potentially counting, as well as a dual counter mode. When programmed as a Dual harmful to persons or equipment in the event of a fault to the meter. Counter, each counter has separate scaling and decimal point selection. Rate indication is available in all count modes. The Rate Indicator has separate scaling and decimal point selection, along with programmable display update times. In addition to the signal inputs, the User Input can be programmed to perform a variety of meter control functions. CAUTION: Risk of Danger. CAUTION: Risk of electric shock. Two setpoint outputs are provided, each with a Form C relay. The Read complete instructions prior to installation and operation of the unit. outputs can activate based on either counter or rate setpoint values. An internal batch counter can be used to count setpoint output activations. The PAXLCR can be powered from a wide range of AC or DC SPECIFICATIONS voltages. The meter has been specifically designed for harsh industrial 1. DISPLAY: 6 digit, 0.56 (14.2 mm) intensity adjustable Red LED environments. With a NEMA 4X/IP65 sealed bezel and extensive testing 2. POWER REQUIREMENTS: to meet CE requirements, the meter provides a tough yet reliable AC POWER: 50 to 250 VAC 50/60 Hz, 12 VA application solution. Isolation: 2300 Vrms for 1 min. to all inputs and outputs DC POWER: 21.6 to 250 VDC, 6 W DC Out: +24 VDC 100 mA if input voltage is greater than 50 VAC/VDC +24 VDC 50 mA if input voltage is less than 50 VDC 3. COUNTER DISPLAYS: ORDERING INFORMATION Counter A: 6-digits, enabled in all count modes MODEL NO. DESCRIPTION PART NUMBER Display Designator: A to the left side of the display PAXLCR Dual Counter & Rate Meter with Dual Relay Output PAXLCR00 Display Range: -99999 to 999999 Counter B: 6-digits, enabled in Dual Count mode or Batch Counter UL Listed Dual Counter & Rate Meter with Dual PAXLCRU PAXLCRU0 Display Designator: B to the left side of the display Relay Output Display Range: 0 to 999999 (positive count only) Overflow Indication: Display alternates with overflowed count value Maximum Count Rates: 50% duty cycle, count mode dependent. DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.1 (53.4) H x 5.0 (127) W. A B 1.95 1.75 SP1PS 2 (49.5) (44.5) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PAR SEL RST .10 4.10 3.80 3.60 (91.4) (2.5) (104.1) (96.5) -1-Drawing No. LP0749 Released 2018-01-16 With setpoints disabled: 25 KHz, all modes except Quadrature x4 (23 Contact Rating: 5 amps 120/240 VAC or 28 VDC (resistive load), KHz). 1/8 H.P. 120 VAC (inductive load) With setpoint(s) enabled: 20 KHz, all modes except Dual Counter (14 Life Expectancy: 100 K cycles min. at full load rating. External RC KHz), Quadrature x2 (13 KHz) and Quadrature x4 (12 KHz). snubber extends relay life for operation with inductive loads. 4. RATE DISPLAY: 6-digits, may be enabled or disabled in any count Response Time: Turn On or Off: 4 msec max. mode 9. ENVIRONMENTAL CONDITIONS: Display Range: 0 to 999999 Operating temperature: 0 to 50 C Over Range Display: Storage temperature: -40 to 70 C Maximum Frequency: 25 KHz Operating and storage humidity: 0 to 85% max. RH (non-condensing) Minimum Frequency: 0.01 Hz Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g. Shock to IEC 68-2-27: Operational 30 g (10 g relay). Accuracy: 0.01% Altitude: Up to 2,000 meters 5. COUNT/RATE SIGNAL INPUTS (INPUT A and INPUT B): 10. CONNECTIONS: High compression cage-clamp terminal block See Section 2.0 Setting the DIP Switches for complete Input Wire Strip Length: 0.3 (7.5 mm) specifications. DIP switch selectable inputs accept pulses from a Wire Gage: 30-14 AWG copper wire variety of sources. Both inputs allow selectable active low or active Torque: 4.5 inch-lbs (0.51 N-m) max. high logic, and selectable input filtering for low frequency signals or 11. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 outdoor use. switch contact debounce. IP20 Touch safe. Installation Category II, Pollution Degree 2. One Input A: Logic level or magnetic pickup signals. piece bezel/case. Flame resistant. Synthetic rubber keypad. Panel Trigger levels: V = 1.25 V max V = 2.75 V min V = 28 VDC IL IH MAX gasket and mounting clip included. Mag. pickup sensitivity: 200 mV peak, 100 mV hysteresis, 40 V 12. CERTIFICATIONS AND COMPLIANCES: peak max. CE Approved Input B: Logic level signals only EN 61326-1 Immunity to Industrial Locations Trigger levels: V = 1.0 V max V = 2.4 V min V = 28 VDC IL IH MAX Emission CISPR 11 Class A 6. USER INPUT: Programmable Safety requirements for electrical equipment for measurement, Software selectable for active logic state: active low, pull-up (24.7 K control, and laboratory use: to +5 VDC) or active high, pull-down resistor (20 K). EN 61010-1: General Requirements Trigger levels: V = 1.0 V max V = 2.4 V min V = 28 VDC IL IH MAX RoHS Compliant Response Time: 10 msec typ. 50 msec debounce (activation and UL Listed: File E179259 For Model No. PAXLCRU0 Only release) 2 Type 4X Enclosure rating (Face only) 7. MEMORY: Nonvolatile E PROM retains all programming parameters IP65 Enclosure rating (Face only) and count values when power is removed. IP20 Enclosure rating (Rear of unit) 8. OUTPUTS: 13. WEIGHT: 10.4 oz. (295 g) Type: Dual Form C contacts Isolation to Input & User/Exc Commons: 1400 Vrms for 1 min. Working Voltage: 150 Vrms 1.0 IstallIn gn the Meter tighten the latch screws evenly until the unit is snug in the panel (Torque Installation to approximately 7 in-lbs 79N-cm ). Do not over-tighten the screws. The PAX Lite meets NEMA 4X/IP65 requirements when properly installed. The unit is intended to be mounted into an enclosed panel. Prepare the panel cutout to the dimensions shown. Remove the panel Installation Environment latch from the unit. Slide the panel gasket over the rear of the unit to the The unit should be installed in a location that does not exceed the back of the bezel. The unit should be installed fully assembled. Insert the maximum operating temperature and provides good air circulation. unit into the panel cutout. Placing the unit near devices that generate excessive heat should be While holding the unit in place, push the avoided. panel latch over the rear of the unit so that The bezel should be cleaned only with a soft cloth and neutral soap the tabs of the panel latch engage in product. Do NOT use solvents. Continuous exposure to direct sunlight the slots on the case. The panel may accelerate the aging process of the bezel. PANEL latch should be engaged in Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to the farthest forward slot operate the keypad of the unit. BEZEL possible. To achieve PANEL CUT-OUT a proper seal, LATCHING PANEL SLOTS LATCH +.03 3.62 -.00 +.8 (92 ) -.0 LATCHING +.02 1.77 -.00 TABS +.5 (45 ) -.0 PANEL GASKET PANEL MOUNTING SCREWS -2-