Bulletin No. PAXICR-E Drawing No. LP0896 Released 04/16 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL PAX - 1/8 DIN DIGITAL INPUT PANEL METERS COUNT, DUAL COUNTER, RATE AND SLAVE DISPLAY 0.56 RED SUNLIGHT READABLE DISPLAY VARIABLE INTENSITY DISPLAY 10 POINT SCALING FOR NON-LINEAR PROCESSES (PAXI) FOUR SETPOINT ALARM OUTPUTS (W/Option Card) RETRANSMITTED ANALOG OUTPUT (W/Option Card) (PAXI) COMMUNICATION AND BUS CAPABILITIES (W/Option Card) (PAXI) BUS CAPABILITIES DEVICENET, MODBUS, AND PROFIBUS-DP CRIMSON PROGRAMMING SOFTWARE (PAXI) ETHERNET(W/ External Gateway) (PAXI) NEMA 4X/IP65 SEALED FRONT BEZEL U R C L US LISTED IND. CONT. EQ. 51EB through the bus. Additionally, the meters have a feature that allows a remote GENERAL DESCRIPTION computer to directly control the outputs of the meter. With an RS232 or RS485 The PAX Digital Input Panel Meters offer many features and performance card installed, it is possible to configure the meter using Red Lions Crimson capabilities to suit a wide range of industrial applications. Available in three software. The configuration data can be saved to a file for later recall. different models, PAXC Counter/Dual Counter, PAXR Rate Meter and the PAXI A linear DC output signal is available as an option card for the PAXI only. The which offers both counting and rate in the same package. Refer to pages 4 - 5 for card provides either 20 mA or 10 V signals. The output can be scaled independent the details on the specific models. The PAXC and PAXR offer only the Setpoint of the input range and can track any of the counter or rate displays. Option, while the PAXI is the fully featured version offering all the capabilities Once the meters have been initially configured, the parameter list may be as outlined in this bulletin as well as a slave display feature. The option cards locked out from further modification in its entirety or only the setpoint values allow the opportunity to configure the meter for present applications, while can be made accessible. providing easy upgrades for future needs. The meters have been specifically designed for harsh industrial environments. The meters employ a bright 0.56 LED display. The meters are available with With NEMA 4X/IP65 sealed bezel and extensive testing of noise effects to CE a red sunlight readable or standard green LED display. The intensity of the requirements, the meter provides a tough yet reliable application solution. display can be adjusted from dark room applications up to sunlight readable, making it ideal for viewing in bright light applications. The meters accept digital inputs from a variety of sources including switch SAFETY SUMMARY contacts, outputs from CMOS or TTL circuits, magnetic pickups and all All safety related regulations, local codes and instructions that appear in this standard RLC sensors. The meter can accept directional, uni-directional or literature or on equipment must be observed to ensure personal safety and to Quadrature signals simultaneously. The maximum input signal varies up to 34 prevent damage to either the instrument or equipment connected to it. If KHz depending on the count mode and function configurations programmed. equipment is used in a manner not specified by the manufacturer, the protection Each input signal can be independently scaled to various process values. provided by the equipment may be impaired. The Rate Meters provide a MAX and MIN reading memory with programmable Do not use this meter to directly command motors, valves, or other actuators capture time. The capture time is used to prevent detection of false max or min not equipped with safeguards. To do so can be potentially harmful to persons or readings which may occur during start-up or unusual process events. equipment in the event of a fault to the meter. Optional digital output cards provide the meter with up to four setpoint outputs. The cards are available as dual relay, quad relay, quad sinking transistor, quad sourcing transistor/SSR drive, or dual triac/dual SSR drive outputs. The setpoint alarms can be configured to suit a variety of control and alarm requirements. CAUTION: Risk of Danger. CAUTION: Risk of electric shock. Communication and Bus Capabilities are also available as option cards for Read complete instructions prior to the PAXI only. These include RS232, RS485, Modbus, DeviceNet, and installation and operation of the unit. Profibus-DP. Readout values and setpoint alarm values can be controlled DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.1 (53.4) H x 5 (127) W. 12 16 20 A 13 17 21 B 14 18 22 1.75 1.95 C 8.8.8.8.8.8 15 19 23 1.75 24 SP1 SP2 SP3 SP4 (49.5) (44.5) 25 (44.5) 1 2 3 4 5 6 7 8 9 10 11 DSP PAR F1 F2 RST .10 4.10 3.80 3.60 (91.4) (2.5) (104.1) (96.5) 1Table Of COn Ten Ts Ordering Information .................... 2 Installing Option Cards .................. 8 General Meter Specifications ............. 3 Wiring the Meter ....................... 9 PAXC Counter ......................... 4 Reviewing the Front Buttons and Display ... 11 PAXR Rate Meter ...................... 4 Programming the Meter . 11 PAXI Counter/Rate Meter ................ 5 Factory Service Operations .............. 28 Option Cards .......................... 6 Troubleshooting ....................... 29 Crimson Programming Software ........... 7 Parameter Value Chart ................. 30 Installing the Meter ..................... 7 Programming Overview ................. 32 Setting the Jumper and DIP Switches ...... 8 Ogrderin i fOn rmaTiOn Meter Part Numbers PAX 0 0 C - Counter/Dual Counter R - Rate Meter I - Counter/Dual Counter/ Rate Meter/Slave Display 0 - Red, Sunlight Readable Display 1 - Green Display 2 - 85 to 250 VAC 3 - 11 to 36 VDC, 24 VAC Option Card and Accessories Part Numbers TYPE MODEL NO. DESCRIPTION PART NUMBER Dual Setpoint Relay Output Card PAXCDS10 Quad Setpoint Relay Output Card PAXCDS20 Quad Setpoint Sinking Open Collector Output Card PAXCDS30 PAXCDS Quad Setpoint Sourcing Open Collector Output Card PAXCDS40 Dual Triac/Dual SSR Drive Output Card PAXCDS50 Quad Form C Relay Output Card PAXCDS60 * RS485 Serial Communications Card with Terminal Block PAXCDC10 Option Cards Extended RS485 Serial Communications Card with Dual RJ11 Connector PAXCDC1C RS232 Serial Communications Card with Terminal Block PAXCDC20 1 PAXCDC Extended RS232 Serial Communications Card with 9 Pin D Connector PAXCDC2C DeviceNet Communications Card PAXCDC30 Profibus-DP Communications Card PAXCDC50 PAXUSB PAX USB Programming Card (Not included in PAX product UL E179259 file). PAXUSB00 PAXCDL Analog Output Card PAXCDL10 2 SFCRD Crimson PC Configuration Software for Windows 2000, XP and Windows 7 SFCRD200 Accessories ICM8 Communication Gateway ICM80000 * This card is not suitable for use in older PAX models. For proper installation, a case knock-out feature must be present on the top surface of the PAX case. This feature began to be introduced to the standard PAX units in July of 2014 (2614). Notes: 1. For Modbus communications use RS485 Communications Card and configure Communication Type parameter (tYPE) for Modbus. 2. Crimson software is available for free download from