Additional Resources: Product Page date 06/07/2016 page 1 of 5 SERIES: VGS-75 DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 76.8 W continuous power compact footprint univ ersal input (88~264 Vac / 125~373 Vdc) single output from 3.3 to 48 V over voltage, over load, and short circuit protections UL/cUL and TUV safety approvals operation high temperature up to 70C long life electrolytic capacitors no load power consumption <0.5 W efficiency up to 90% RoHS output output output ripple and efficiency MODEL voltage current power noise max max max (Vdc) (A) (W) (mVp-p) (%) VGS-75-3.3 3.3 15 49.5 150 79 VGS-75-5 5 15 75 150 83 VGS-75-12 12 6 72 150 87 VGS-75-15 15 5 75 150 87 VGS-75-24 24 3.2 76.8 150 88 VGS-75-48 48 1.6 76.8 200 90 PART NUMBER KEY VGS-75 - XX Base Number Output Voltage cui.com DISCONTINUEDAdditional Resources: Product Page CUI Inc SERIES: VGS-75 DESCRIPTION: AC-DC POWER SUPPLY date 06/07/2016 page 2 of 5 INPUT parameter conditions/description min typ max units withstand 300 Vac surge for 5 seconds 88 264 Vac voltage range without damage 125 373 Vdc frequency range 50 60 Hz at 115 Vac, cold start 2 A current at 230 Vac, cold start 1 A inrush current at 230 Vac, full load, cold start 40 A leakage current at 230 Vac 2 mA OUTPUT parameter conditions/description min typ max units voltage adjust 10 3.3 V models 3 % voltage tolerance 5 V models 2 % all other models 1 % line regulation low line to high line 0.5 % from 0% to full load 3.3 V models 3.0 % load regulation 5 V models 2.0 % all other models 0.5 % rise time at 115/230 Vac, full load 80 ms at 115 Vac, cold start 10 ms hold-up time at 230 Vac, cold start 32 ms PROTECTIONS parameter conditions/description min typ max units over load Hiccup mode, auto recovery 110 % over voltage latch off mode 115 150 % short circuit continuous SAFETY & COMPLIANCE parameter conditions/description min typ max units input to output: 4,242 Vdc isolation voltage input to frame ground: 2,121 Vdc output to frame ground: 707 Vdc input to output, input to frame ground, output to insulation resistance 100 M frame ground at 500 Vdc safety approvals UL 60950-1 / TUV EN 60950-1 EN 55022: 1998+A1 : 2000+A2 : 2003 Class B, EN 61000-3-2 : 2000+A2 EMI/EMC : 2005 Class A, EN 61000-3-3 : 1995+A1 : 2001, EN 61204-3 : 2000 EN 50204 1998+A1 : 2001+A2 : 2003 light industry level, criteria A RoHS compliant 2011/65/EU MTBF as per MIL-HDBK-217F, 25C 351,000 hrs ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curve -25 70 C storage temperature see derating curve -40 85 C operating humidity non-condensing 20 90 % cui.com DISCONTINUED