Users Guide AC/DC Converter Isolation Fly-back Converter PWM method Output 24W 12V BM2P0161 Reference Board BM2P0161-EVK-003 ROHM BM2P0161-EVK-003 is from wide input voltage (90Vac264Vac) to output 12V 2A max. Constant Voltage Reference board. It used to PWM method DC/DC Converter IC BM2P0161. BM2P0161 is including 650V High voltage power MOSFET and starter. The starter realize low Stand-by Power. Output voltage control method is used current mode regulation, therefore it can used cycle by cycle current limit. Quick response in dynamic load changing is achieved. Switching frequency is fixed 65 kHz. Light load situation has frequency decrease function for higher efficiency. Switching frequency jitter function enables lower EMI operation. Various functions are included for safety, Soft start, Frequency Burst Mode, VCC OVP, Output OLP and thermal shut down. Electronics Characteristics Not guarantee the characteristics, is representative value. Unless otherwise noted: VIN = 230Vac, IOUT = 500mA, Ta: 25C Table 1. Evaluation Board Specification Description Min Typ Max Units Conditions Input Voltage Range 90 - 264 Vac Input Frequency Range 47 50/60 63 Hz Output Voltage 10.8 12.0 13.2 V Output Maximum Power - - 24 W IOUT =2A Output Current Range 0.0 1.5 2.0 A (Note 1) No Load Power Consumption - 73 - mW IOUT = 0A Efficiency 80.0 86.0 - % Output:24V 1.5A Output Ripple Voltage - 190 - mV BW=20MHz, (note 2) (NOTE1) Please adjust operating time, within any parts surface temperature under 105C (NOTE2) Not include spike noise 2018 ROHM Co., Ltd. No. 60UG092E Rev.001 1/20 JULY.2018BM2P0161-EVK-003 Users Guide Operation Procedure 1. Operation Equipment (1) AC Power supply 90Vac264Vac, over 100W (2) Electronic Load capacity 2A (3) Multi meter 2. Connect method (1) AC power supply presetting range 90~264Vac, Output switch is off. (2) Load setting under 2A. Load switch is off. (3) AC power supply N terminal connect to the board AC (N) of CN1, and L terminal connect to AC (L). (4) Load + terminal connect to VOUT, GND terminal connect to GND terminal (5) AC power meter connect between AC power supply and board. (6) Output test equipment connects to output terminal (7) AC power supply switch ON. (8) Check that output voltage is 12V. (9) Electronic load switch ON (10) Check output voltage drop by load connect wire resistance + Electric V LOAD AC power - Supply Power Meter Figure 1. Connection Circuit DC Multi Meter Deleting Maximum Output Power Po of this reference board is 24W. The derating curve is shown on the right. Please adjust load continuous time by over 105C of any parts surface temperature within the operating temperature range (-10~65C). Po W 30W 30W 24W 24W Ta 65 -10 25 50 Figure 2. Temperature Deleting curve 2018 ROHM Co., Ltd. No. 60UG092E Rev.001 2/20 JULY.2018