DATASHEET Single-Stage Filters FN 2010 General Purpose EMI Filter Rated currents from 1 to 60 A Approvals General purpose filtering performance Optional medical versions (B type) Optional safety versions (A type) Features and benefits FN 2010 filters are designed for easy and fast chassis mounting FN 2010 filters are also available as B versions without Y-capacitors for medical applications as well as A version with low capacitance for safety critical applications with necessity for low leakage currents All filters provide a general purpose conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior FN 2010 filters can be used to cover a broad range of usage and they offer a good size/amperage ratio FN 2010 filters are also available as two-stage filters (FN 2060, FN 2070 series) for more noisy environment Various terminal options allow you to select the Technical specifications desired connection style Operating voltage 110/250 VAC, 50/60 Hz Typical applications Operating frequency dc to 400 Hz Rated currents 1 to 60 A 40 C max. Electrical and electronic equipment High potential test voltage P > PE 2000 VAC for 2 sec Consumer goods P > N 1100 VDC for 2 sec (30 and 60 A types) Household equipment P > N 760 VAC for 2 sec (1 to 20 A types) Medical equipment P > PE 2500 VAC for 2 sec (B types) Office automation equipment Temperature range (operation and storage) -25 C to +100 C (25/100/21) Flammability corresponding to UL 94 V-2 or better Datacom equipment Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 MTBF 40C/230V (Mil-HB-217F) 1,250,000 hours Typical electrical schematic 3,200,000 hours (B types) 2 EMC/EMI Products Schaffner Group Datasheets 2015 Filter selection table Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight 40 C (25 C) 230 VAC/50 Hz L Cx Cy R connections A mA mH F nF k g FN 2010-1-.. 1 (1.15) 0.74 12 0.1 4.7 1000 -06 -07 65 FN 2010-3-.. 3 (3.45) 0.74 2.5 0.1 4.7 1000 -06 -07 65 FN 2010-6-.. 6 (6.9) 0.74 1 0.1 4.7 1000 -06 -07 65 FN 2010-10-.. 10 (11.5) 0.74 0.8 0.1 4.7 1000 -06 -07 85 FN 2010-12-.. 12 (13.8) 0.74 0.7 0.1 4.7 1000 -06 -07 85 FN 2010-16-.. 16 (18.4) 0.74 0.7 0.1 4.7 1000 -06 -07 140 FN 2010-20-.. 20 (23) 0.74 0.6 0.1 4.7 1000 -06 -07 -08 210 FN 2010-30-08 30 (34.5) 0.87 0.7 0.47 10 1000 -08 470 FN 2010-60-24 60 (69) 0.87 1 1.5 10 330 -24 1100 FN 2010A-1-.. 1 (1.15) 0.074 12 0.1 0.47 1000 -06 -07 65 FN 2010A-3-.. 3 (3.45) 0.074 2.5 0.1 0.47 1000 -06 -07 65 FN 2010A-6-.. 6 (6.9) 0.074 1 0.1 0.47 1000 -06 -07 65 FN 2010A-10-.. 10 (11.5) 0.074 0.8 0.1 0.47 1000 -06 -07 85 FN 2010A-12-.. 12 (13.8) 0.074 0.7 0.1 0.47 1000 -06 -07 85 FN 2010A-16-.. 16 (18.4) 0.074 0.7 0.1 0.47 1000 -06 -07 140 FN 2010A-20-.. 20 (23) 0.074 0.6 0.1 0.47 1000 -06 -07 -08 210 FN 2010A-30-08 30 (34.5) 0.074 0.7 0.47 0.47 1000 -08 470 FN 2010A-60-24 60 (69) 0.074 1 1.5 0.47 330 -24 1100 FN 2010B-1-.. 1 (1.15) 0.002 12 0.1 1000 -06 -07 65 FN 2010B-3-.. 3 (3.45) 0.002 2.5 0.1 1000 -06 -07 65 FN 2010B-6-.. 6 (6.9) 0.002 1 0.1 1000 -06 -07 65 FN 2010B-10-.. 10 (11.5) 0.002 0.8 0.1 1000 -06 -07 85 FN 2010B-12-.. 12 (13.8) 0.002 0.7 0.1 1000 -06 -07 85 FN 2010B-16-.. 16 (18.4) 0.002 0.7 0.1 1000 -06 -07 140 FN 2010B-20-.. 20 (23) 0.002 0.6 0.1 1000 -06 -07 -08 210 FN 2010B-30-08 30 (34.5) 0.002 0.7 0.47 1000 -08 470 FN 2010B-60-24 60 (69) 0.002 1 1.5 330 -24 1100 ** To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2010-30-08, FN 2010B-10-06). ** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Typical filter attenuation Per CISPR 17 A = 50 /50 sym B = 50 /50 asym C = 0.1 /100 sym D = 100 /0.1 sym 1 and 3 A types 6 to 12 A types 16 and 20 A types 30 and 60 A types