DATASHEET Single-Stage Filters FN 2030 General Purpose AC/DC EMI Filter with High Attenuation Performance Rated currents from 1 to 30 A Approvals High performance filter attenuation High differential-mode attenuation Optional medical versions (B type) Optional safety versions (A type) Optional enhanced performance versions Optional overvoltage protection (Z type) Features and benefits FN 2030 filters are designed for easy and fast chassis mounting Performance indicators The FN 2030 filters are also available as B versions with no Y-capacitors for medical applications as well as A versions with low capacitance for safety critical applications with a requirement for low leakage currents FN 2030 filters offer an optimized filter range for high performance AC and DC applications , in same compact size (M, N1 types) All filters provide an exceptional conducted attenuation performance, based on chokes with high permeable core material and excellent thermal behavior The higher inductivity versus amperage offers Technical specifications increased attenuation performance with same form factor compared to FN 2010 and FN 2020 filter series All FN 2030 filters can be delivered with optional Rated voltage* 250 VAC, 50/60 Hz 250 VDC surge pulse protection (Z type). Operating frequency dc to 400 Hz Various terminal options allow you to select the Rated currents 1 to 30 A 40C max. desired connection style P > PE 2000 VAC for 2 sec (equiv. cap <88 nF) High potential test voltage P > PE 2550 VDC for 2 sec (equiv. cap >88 nF) P > PE 2500 VAC for 2 sec (B types) Typical application P > N 1100 VDC for 2 sec Temperature range (operation and storage) -25C to +100C (25/100/21) Electrical and electronic equipment Certified to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to Consumer goods AC and DC applications) Household equipment Flammability corresponding to UL 94 V-2 or better Medical equipment Surge pulse protection (Z type) 2 kV (P-N), IEC 61000-4-5 Electronic data processing equipment MTBF 40C/230 V (Mil-HB-217F) 2,200,000 hours (1 to 10 A types) 1,200,000 hours (12 to 30 A types) Office automation and datacom equipment Various noisy applications requiring high filter *maximum RMS operating voltage at rated frequency or the maximum DC operating voltage performance Typical electrical schematic2 EMC/EMI Products Schaffner Group Datasheets 2017 Filter selection table Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight 40C (25C) 250 VAC/50 Hz L Cx Cy R connections ( 120 VAC/60 Hz) A mA mH F nF k g FN 2030-1-.. 1 (1.1) 0.31 (0.18) 20 0.22 2.2 1000 -06 -07 58 FN 2030-3-.. 3 (3.4) 0.47 (0.27) 14 0.33 3.3 1000 -06 -07 87 FN 2030-4-.. 4 (4.5) 0.47 (0.27) 14 0.33 3.3 1000 -06 -07 92 FN 2030-6-.. 6 (6.7) 0.66 (0.38) 8 0.47 4.7 680 -06 -07 100 FN 2030-8-.. 8 (8.9) 0.66 (0.38) 8 0.47 4.7 680 -06 -07 170 FN 2030-10-.. 10 (11.2) 0.66 (0.38) 8 0.47 4.7 680 -06 -07 196 FN 2030-12-.. 12 (13.4) 0.79 (0.45) 4 1.0 10 330 -06 -07 185 FN 2030-16-.. 16 (17.9) 0.79 (0.45) 4 1.0 10 330 -06 -07 225 FN 2030-20-.. 20 (22.4) 0.79 (0.45) 4 1.0 10 330 -06 -08 285 FN 2030-30-08 30 (33.5) 0.79 (0.45) 2 1.0 10 330 -08 326 FN 2030 A-1-.. 1 (1.1) 0.07 (0.04) 20 0.22 0.47 1000 -06 -07 58 FN 2030 A-3-.. 3 (3.4) 0.07 (0.04) 14 0.33 0.47 1000 -06 -07 87 FN 2030 A-4-.. 4 (4.5) 0.07 (0.04) 14 0.33 0.47 1000 -06 -07 92 FN 2030 A-6-.. 6 (6.7) 0.07 (0.04) 8 0.47 0.47 680 -06 -07 100 FN 2030 A-8-.. 8 (8.9) 0.07 (0.04) 8 0.47 0.47 680 -06 -07 170 FN 2030 A-10-.. 10 (11.2) 0.07 (0.04) 8 0.47 0.47 680 -06 -07 196 FN 2030 A-12-.. 12 (13.4) 0.07 (0.04) 4 1.0 0.47 330 -06 -07 185 FN 2030 A-16-.. 16 (17.9) 0.07 (0.04) 4 1.0 0.47 330 -06 -07 225 FN 2030 A-20-.. 20 (22.4) 0.07 (0.04) 4 1.0 0.47 330 -06 -08 285 FN 2030 A-30-08 30 (33.5) 0.07 (0.04) 2 1.0 0.47 330 -08 326 FN 2030 B-1-.. 1 (1.1) 0.00 20 0.22 1000 -06 -07 58 FN 2030 B-3-.. 3 (3.4) 0.00 14 0.33 1000 -06 -07 87 FN 2030 B-4-.. 4 (4.5) 0.00 14 0.33 1000 -06 -07 92 FN 2030 B-6-.. 6 (6.7) 0.00 8 0.47 680 -06 -07 100 FN 2030 B-8-.. 8 (8.9) 0.00 8 0.47 680 -06 -07 170 FN 2030 B-10-.. 10 (11.2) 0.00 8.45 0.47 680 -06 -07 196 FN 2030 B-12-.. 12 (13.4) 0.00 4 1.0 330 -06 -07 185 FN 2030 B-16-.. 16 (17.9) 0.00 4 1.0 330 -06 -07 225 FN 2030 B-20-.. 20 (22.4) 0.00 4 1.0 330 -06 -08 285 FN 2030 B-30-08 30 (33.5) 0.00 2 1.0 330 -08 326 Enhanced performance FN 2030 N1-1-06 1 (1.1) 5.34 (3.08) 20 0.22 68 1000 -06 65 FN 2030 M-3-06 3 (3.4) 3.69 (2.28) 14 0.33 47 1000 -06 110 FN 2030 M-4-06 4 (4.5) 3.69 (2.28) 14 0.33 47 1000 -06 110 FN 2030 M-6-06 6 (6.7) 3.69 (2.28) 8 0.47 47 680 -06 120 FN 2030 N1-8-06 8 (8.9) 5.34 (3.08) 8 0.47 68 3680 -06 200 FN 2030 N1-10-06 10 (11.2) 5.34 (3.08) 8 0.47 68 680 -06 200 FN 2030 N1-12-06 12 (13.4) 5.34 (3.08) 4 1.0 68 330 -06 210 FN 2030 M-16-06 16 (17.9) 3.69 (2.28) 4 1.0 47 330 -06 265 FN 2030 M-20-.. 20 (22.4) 3.69 (2.28) 4 1.0 47 330 -06 -08 326 FN 2030 M-30-08 30 (33.5) 3.69 (2.28) 2 1.0 47 330 -08 346 * To compile a complete part number, please replace the -.. with the required I/O connection style. For surge pulse protection, please add Z (e.g. FN 2030Z-10-06, FN 2030BZ-20-08). The different letters code the used Cy values in the filter type (A = 0.47nF M = 47nF N1 = 47nF) ** Maximum leakage under usual AC operating conditions (acc. IEC60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Leakage current for DC application is 0 mA