DATASHEET PCB Filters FN402 Low Cost PCB Filter Rated currents from 0.5 to 6.5 A Approvals & Compliances Compact PCB-mountable design Very low profile Optional medical versions (B type) The FN 402 PCB filter is a single-phase filter designed Performance indicators for easy and fast PCB-mounting. Choosing the FN 402 product line brings you the rapid availability of a standard filter associated with the necessary safety acceptance. Standard PCB single-phase filters are a practical solution helping you to pass EMI system approval in a short time. A selection on amperage ratings and medical types are designed to offer you the desired standard product. Features and benefits Good conducted attenuation performance, based on chokes with high saturation resistance and Technical specifications excellent thermal behavior PCB through hole mounting Maximum continuous operating voltage 250 VAC, 50/60 Hz Low cost low profile Operating frequency DC to 400 Hz Custom specific versions on request Rated currents 0.5 to 6.5 A 40C max. High potential test voltage P > PE 2000 VAC for 2 sec (standard types) Typical applications P > N 760 VAC for 2 sec P > PE 2500 VAC for 2 sec (B types) Electrical and electronic equipment Temperature range (operation and storage) -25C to +100C (25/100/21) Small to medium-sized machines and household Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 equipment Flammability corresponding to UL 94 V-0 or better Single-phase power supplies, switch-mode power MTBF 40C/230 V (Mil-HB-217F) 1,900,000 hours supplies Test and measurement equipment Medical equipment Typical electrical schematic2 EMC/EMI Products Schaffner Group Datasheets 05 Jan 2022 Filter selection table Filter Rated current Leakage current* Inductance** Capacitance** Resistance** Input/Output Weight 40C (25C) 230 VAC/50 Hz L Cx Cy R connections A A mH nF nF k g FN 402-0.5-02 0.5 (0.6) 373 40 100 2.2 1000 -02 40 FN 402-1-02 1 (1.2) 373 10 100 2.2 1000 -02 40 FN 402-1.6-02 1.6 (1.9) 373 6 100 2.2 1000 -02 40 FN 402-2.5-02 2.5 (3) 373 2 100 2.2 1000 -02 40 FN 402-4-02 4 (4.7) 373 1 100 2.2 1000 -02 40 FN 402-6.5-02 6.5 (7.5) 373 1 100 2.2 1000 -02 40 FN 402 B-0.5-02 0.5 (0.6) 2 40 100 1000 -02 40 FN 402 B-1-02 1 (1.2) 2 10 100 1000 -02 40 FN 402 B-1.6-02 1.6 (1.9) 2 6 100 1000 -02 40 FN 402 B-2.5-02 2.5 (3) 2 2 100 1000 -02 40 FN 402 B-4-02 4 (4.7) 2 1 100 1000 -02 40 FN 402 B-6.5-02 6.5 (7.5) 2 1 100 1000 -02 40 ** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. ** Tolerances apply: Inductance: -30/+50%, Capacitance: 20%, Resistance: 10% Product selector For example: FN 402-0.5-02, FN 402 B-6.5-02