Feedthrough components FN 756X DC feedthrough capacitor EN/IEC 60384-14 approval Approvals Rated currents from 10 to 200A 2.5kV pulse test capability Class Y4 capacitor Technical specifications Typical electrical schematic C Maximum continuous operating voltage: 130VDC (UL, ENEC) 130VAC, 50/60Hz (UL, ENEC) 650VDC max. Rated currents: 10 to 200A 60C max. Capacitor class: Y4 High potential test voltage: 1700VDC for 2 sec Insulation resistance (100VDC after 60 sec): < 0.33F, R > 1500M > 0.33F, > 5000s Temperature range (operation and storage): -40C to +100C (40/100/21) Flammability corresponding to: UL 94V-2 or better MTBF 60C/130V (Mil-HB-217F): < 200A: > 1,400,000 hours 200A: > 450,000 hours Features and benefits Typical applications Very low internal series inductance. Power line filter for 48VDC battery power Feedthrough capacitors offer a high insertion Very high self-resonant frequency. Increasing system and information security loss across a broad band of frequencies from Self-healing dielectric. Telecom base stations a few tens of kHz up to the GHz region. The High quality and reliability. Switching and cellular equipment construction of feedthrough capacitors cause Through-bulkhead mounting. Computer servers a better suppression performance over a much Anti-twist protection. UPS power supplies wider frequency range than a conventional Custom-specific or dual-versions on Medical equipment two-wire capacitor of equivalent value. Different versions are available offering a request. wide selection on operating currents and per- formance levels. DC feedthrough capa- citors are designed and approved for 130VDC/130VAC 50/60Hz operation.> Components > FN 756X Feedthrough selector table Feedthrough Rated current Leakage current* Capacitance** DC resistance*** Weight 60C 130VAC/50Hz C R 25C A mA nF m g FN 7560-10-M3 10 0.49 10 0.8 15 FN 7562-16-M4 16 4.9 100 0.62 34 FN 7563-16-M4 16 23 470 0.63 78 FN 7562-32-M4 32 4.9 100 0.62 34 FN 7563-32-M4 32 23 470 0.63 79 FN 7560-63-M6 63 0.49 10 0.3 70 FN 7561-63-M6 63 2.3 47 0.3 70 FN 7562-63-M6 63 4.9 100 0.3 70 FN 7563-63-M6 63 23 470 0.43 103 FN 7560-100-M8 100 2.3 47 0.23 145 FN 7561-100-M8 100 4.9 100 0.23 145 FN 7562-100-M8 100 23 470 0.23 145 FN 7563-100-M8 100 49 1000 0.25 192 FN 7560-200-M10 200 4.9 100 0.16 160 FN 7561-200-M10 200 23 470 0.16 160 FN 7562-200-M10 200 49 1000 0.18 268 FN 7563-200-M10 200 230 4700 0.14 490 * Tolerance +20% ** Tolerance 20% *** Tolerance +15% Typical filter attenuation 50 system 10A types 16A types 32A types 63A types 100A types 200A types