Ref. CCT15450 - CCT15451 en Discover your IHP CCT15452 - CCT15453 IHP A B C Date, Time, Day (Day 1 = Monday by default) 1 D Output contact status display (alternating C1/C2 for cat. nos. CCT15452 and CCT15453) C1 C2 E Viewing On periods per 30-minute 24 6 Cable OFF 13 5 segment 24 6 F Operating mode:AUT,PRO: ON 13 5 programming, : time setting, MA: programming Holiday, Time 1 230 V AC supply +10 %, -15 %, Delay and Random functions for cat. 50/60 Hz C2 nos. CCT15451 and CCT15453, : 2 Lea et-holder adapt the con guration 3 Sealable cover GP: afternoon 4 Output contacts HMen: select the operating mode 5 LCD screen (back-lit on cat. nos. I ,: value setting and navigation CCT15451 and CCT15453) keys 6 Programming key storage J o: ashing information validation C1 7 Programming key connector (only cat. key nos. CCT15451 and CCT15453) 8 External control input only for cat. nos. Reset by pressing simultaneously the 4 CCT15451 and CCT15453 (Ext 1 for keys ,,Men ando i.e. H I Note: channel 1 and Ext 2 for channel 2) and J . 2The external input operating mode is de ned in the chapter Adapt the con guration . Con gure On energisation or once you have carried out a Reset Zone Summer time Winter time Comments (see Discover chapter): b Choose the language (French, English, etc.). EUROPE Last Sunday in Last Sunday in b Choose to delete or to keep the program existing in the March at 2 a.m. October at 3 a.m. product. b Set the year, month, day and time. GB/IRL/P Last Sunday in Last Sunday in Great Britain - Portugal b Choose the summer/winter time changeover parameters. March at 1 a.m. October at 2 a.m. Once this phase is completed, your IHP will move to the FIN/GR/TR Last Sunday in Last Sunday in Finland - Greece - TurkeyAUT mode and operate with the elements de ned opposite. March at 3 a.m. October at 4 a.m. CDN First Sunday in April Last Sunday in Canada If you do not agree with the ashing value or word: scroll at 2 a.m. October at 3 a.m. up and down the display using the and keys. To con rm the ashing value or word: validate witho. FREE RULE As per choice As per choice Choice of month, week, day If you are lost: pressMen to return to theAUT mode (Monday, Tuesday, etc.) and time without saving the last modi cation. If you do not press a key for 2 minutes: FIX DATE As per choice As per choice Choice of month, date (01, 02...) 3 your IHP will move to theAUT mode and operate with the and time elements de ned opposite. NONE - - Program your IHPPRO Date / Time The IHP allows you to program 2 types of control: Modify the time, date, summer/winter time, day of the week, time format, date format. switching operations (On / Off) and pulses (On / Off, on IHP+ products cat. nos. CCT15451 and CCT15453). PressMen, access the mode using the key: To create an operating period: program an On switching followed by an Off switching. b Change the time and date. The COPY function allows you to repeat the created switching operation or pulse for other days of the week and save memory space (creation of abloc). b Choose summer/winter time (see the table in the Access thePRO mode by pressing theMen key you now have 5 possibilities:Con gur chapter). bNE: to build the program and enter it in the memory. b De ne the 1st day of the week (for example Monday for Europe). bCHEC: to view the program. b Modify the format of the dateFORM DAT: bMODIF: to update the program already in the memory. v D / M / Y If the transition selected to be modi ed is repeated on other days of the week, the product v M / D / Y proposesMODIFY BLOC, this function lets you modify all identical transitions (type and v Y / M / D. time). b Modify the format of the time24h / 12: 5 v 24h display 4 bDELET: to delete part of or the whole of the program (date, time and choice of language v 12h display. are kept). If the transition selected to be deleted is repeated on other days of the week, the product proposesDELETE BLOC, this function lets you delete all identical transitions (type and time). bEN: to leave thePRO mode.Adapt the con guration Manual modeMA In this mode you can: In this mode, you can: b Program a holiday periodHOLIDA (temporarily cancel On periods by con guring start and b View the counter indicating output operating time and, if end of absence dates and times). you want, reset this counter. b On cat. nos. CCT15451 and CCT15453, you can also: v modify for an adjustable duration, operation (On or Off on channel) from the current time b De ne the type of external input (this choice must be TIME made in keeping with the element cabled to the product) v use the product in random modeRANDO (to carry out presence simulation). and its operating mode (only on cat. nos. CCT15451 and To carry out one of these operations, you must: pressMen, access theMA mode via CCT15453). There are three possible choices: the key. v NOT ACTIVE bHOLIDA: there are four different operation types in this Holiday mode: v BUTTON vO: output activated v SWITCH. vOF: output de-activated vRANDOM1 : random operation in a xed On range Once the type is de ned, you must de ne the operating mode: vRANDOM2 : On operation in a range with a random start and end. v for the pushbutton: Once you have de ned the type of operation, you must enter the start and end of absence dates. - OVERRIDE: temporary forcing until the next switching bTIME: to de ne the status of the waiver and its duration. operation - TIMER: press to start a time delay for a set period of time. bRANDO: This time delay is possible in On or Off mode at output level. vRANDOM1 6 7 v for the switch: vRANDOM2 . - permanent On Its operation is identical to the Holiday mode, but without limitation in duration. - permanent Off - blocking. ON-OFF override Channel 1, Channel 2 For the rst two choices, the switch is open in normal b Activate ON override or OFF override (until the next switching operation) by pressing operation and its closure results in an On or Off at the output. simultaneously both keys for C1 or for C2 for less than 2 s. The output contact For the third choice, the switch is closed in normal operation changes status: and its opening imposes an Off (relay open) at the output. v the IHP indicates byC1 OVERRI orC2 OVERRI the new status of the output contact v return to the automatic mode by pressing both these keys for less than 2 s. b De ne operation of LCD illumination (only on cat. nos. CCT15451 and CCT15453). b Move to permanent ON or permanent OFF by pressing simultaneously both keys v there are two choices: for C1 or for C2 for more than 2 s: each time you press a key for more than 2 s, the - after 1 min off: lighting goes off 1 min after the last time one of the front face keys is pressed output contact changes status: - always on. v the IHP indicates byC1 PER orC2 PER the new status of the output contact v return to the automatic mode by pressing both these keys for less than 2 s. b Modify language. b The IHP also allows external override by an external pushbutton or switch, cabled on b Return to the product initialisation phase Con gur the terminal (reference 8 , cat. nos. CCT15451 and CCT15453): chapter). permanent On or Off override by external input (switch) takes priority over the ON OFF override function of the product. To perform one of these operations you must: press For con guration of the external input, seeAdapt the con guration.Men, access the mode using the key. 8 bOPERATING HOU: access the output activated counter: Electronic key (cat. no. CCT15861) vSHOW HOU: read the counter vDELET: reset the counter. b You have an electronic key to facilitate programming of your IHP. The key should: v be placed in its compartment (beneath theMen and keys) if you use it bEXT INPU: to de ne the input type and operation. v be placed under the lea et-holder when it is not used. Before placing your electronic key, set the product toAut. bLCD-ILLUMINATIO: Insert the electronic key and a speci c menu will appear. vAFTER 1 MINUTE OF: lighting goes off 1 minute after d Installation of the electronic key inhibits theMen and keys. To move and vali- the last time a key is pressed date, you must use andO. vALWAYS O. bCOPY KEY V TSW: to copy the electronic key program to your IHP. bCOPY TSWI V KE: to copy the IHP program to the electronic key. bLANGUAG. bRUN KE: to operate the IHP with the programming memorised in the electronic key, without program transfer. bFACTORY SETTING. bCHECK KE: to read the content of the electronic key, each programming step is then displayed by pressing the key. PressO to return to the main menu. bEN: to remove the electronic key. An electronic key programming kit (cat. no. CCT15860) including a PC/electronic key interface, a lead, an electronic key and a programming software lets you program your electronic key directly from a PC. 9 Load table Technical data b Permissible output contact power: b Consumption: v resistive loads: I max. = 16 A - 250 Va, I min. =200 mA - 12 V v 1 channel max. 4 VA v motors: 2300 VA. v 2 channels max. 7 VA Lighting type/load Max. power b Memory: 56 switching operations except cat. nos. CCT15451 and CCT15453, 84 switching operations 16 A resistive load (cos = 1) b Minimum time between two switching operations: 1 minute inductive load (cos = 0.6) 10 A b Back-up of program and time by lithium battery: operating incandescent (230 V) 2300 W reserve: 6 years. b Operating temperature: -25C to +45C halogen (230 V) 2300 W b Insulation class: II as per EN 60730-1 in installed state series corrected / non-corrected, uorescent 26 x 36 W, 20 x 58 W, 10 x 100 W b Degree of protection: IP20B as per EN 60529 2 parallel-corrected, uorescent, with 10 x 36 W (4,7 F), 6 x 58 W (7 F), b Connection terminals: 2 x 0.5 to 2.5 mm , rigid and exible conventional ballast 2 x 100 W (18 F) wires dual-mounted, uorescent 10 x (2 x 58 W), 5 x (2 x 100 W) b Overall dimensions: 5 modules uorescent, with electronic ballast 9 x 36 W, 6 x 58 W External input dual-mounted, uorescent, with electronic 5 x (2 x 36 W), 3 x (2 x 58 W) b Voltage: 230 Va +10 %, -15 % ballast b Frequency: 50/60 Hz 10 11 uo-compact, with electronic ballast 9 x 7 W, 7 x 11 W, 7 x 15 W, 7 x 20 W b Input current: max. 1.2 mA parallel-corrected, mercury vapour, uorescent 1 x 250 W (30 F) b Consumption: max. 0.3 W b Cable length: max. 100 m. parallel-corrected, sodium vapour 1 x 250 W (37 F) For the other applications, relay using a CT contactor. Schneider Electric Industries SAS This product must be installed, connected and used in compliance with prevailing standards and/or installation regulations. 35 rue Joseph Monier As standards, speci cations and designs develop from time to time, always ask for con rmation of the information given in this publication. CS 30323 F-92506 Rueil Malmaison Cedex (France) tel : +33 (0)1 41 29 70 00