Product data sheet RM17TG20 Characteristics phase control relay RM17-T - range 183..484 V AC Product availability: Stock - Normally stocked in distribution facility Main Range of product Zelio Control Product or component Modular measurement and control relays type Relay type Control relay Product specific applica- For 3-phase supply tion Relay name RM17TG Relay monitored para- Phase sequence meters Asymmetry Time delay Without Switching capacity in 1250 VA VA Measurement range 208...480 V voltage AC Complementary Maximum switching voltage 250 V AC 250 V DC Minimum switching current 10 mA at 5 V DC Supply voltage limits 183...484 V AC Control circuit voltage limits - 12 % + 10 % Un Power consumption in VA 0...22 VA at 400 V AC 50 Hz Voltage detection threshold < 100 V for phase failure AC Control circuit frequency 50...60 Hz +/- 10 % Output contacts 2 C/O Nominal output current 5 A Measurement voltage limits 183...528 V AC Delay at power up <= 650 ms Voltage range 183...484 V Response time <= 130 ms in the event of a fault Marking CE Overvoltage category III conforming to IEC 60664-1 Insulation resistance > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 Ui rated insulation voltage 400 V conforming to IEC 60664-1 Supply frequency 50/60 Hz +/- 10 % Operating position Any position without Connections - terminals Screw terminals 1 x 0.5...1 x 4 mm - AWG 20...AWG 11, solid cable without ca- ble end Screw terminals 2 x 0.5...2 x 2.5 mm - AWG 20...AWG 14, solid cable without cable end Screw terminals 1 x 0.2...1 x 2.5 mm - AWG 24...AWG 12, flexible cable with ca- ble end Screw terminals 2 x 0.2...2 x 1.5 mm - AWG 24...AWG 16, flexible cable with ca- ble end Tightening torque 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1 Housing material Self-extinguishing plastic Local signalling LED yellow relay ON Mounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715 Electrical durability 10000 cycles Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Mechanical durability <= 30000000 cycles Operating rate <= 360 operations/hour under full load Utilisation category AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 Safety reliability data MTTFd = 924.6 years B10d = 850000 Width 0.69 in (17.5 mm) Product weight 0.29 lb(US) (0.13 kg) Environment Electromagnetic compatibility Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to EN/IEC 61000-6-2 Standards EN/IEC 60255-1 Product certifications CSA GOST C-Tick UL GL Directives 89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive Ambient air temperature for storage -40...158 F (-40...70 C) Ambient air temperature for operation -4...122 F (-20...50 C) Relative humidity 95 % at 131 F (55 C) conforming to IEC 60068-2-30 Vibration resistance 0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6 1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1 Shock resistance 15 gn 11 ms conforming to IEC 60255-21-1 IP degree of protection IP20(Terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 Dielectric test voltage 2 kV 1 min AC 50 Hz Non-dissipating shock wave 4 kV Ordering and shipping details Category 22380 - RELAYS-MEASUREMENT (RM17-RM35) Discount Schedule CP2 GTIN 00785901706854 Nbr. of units in pkg. 1 Package weight(Lbs) 0.20999999999999999 Returnability Y Country of origin ID Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 0701 - Schneider Electric declaration of conformity Schnei- der Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Available California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Lead and lead compounds, which is known to the State of California to cause can- cer and birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov 2