Product data sheet RM35LM33MW Characteristics liquid level control relay RM35-L - 24..240 V AC/DC Product availability: Stock - Normally stocked in distribution facility Main Range of product Zelio Control Product or component Modular measurement and control relays type Relay type Level control relay Relay name RM35L Relay monitored para- Detection by resistive probes meters Time delay Adjustable 0.1...5 s, +/- 10 % Switching capacity in 1250 VA VA Minimum switching cur- 10 mA at 5 V DC rent Maximum switching cur- 5 A AC/DC rent Power consumption <= 5 VA AC Measurement range 250 Ohm...1 MOhm Utilisation category AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 Complementary Reset time 1750 ms Maximum switching voltage 250 V AC/DC Un rated nominal voltage 24...240 V AC/DC 50/60 Hz +/- 10 % Supply voltage limits 20.4...264 V AC/DC Operating voltage tolerance - 15 % + 10 % Un Power consumption <= 1.5 W DC Output contacts 2 C/O Nominal output current 5 A Delay at power up 0.6 s Measurement accuracy +/- 10 % of the full scale value +/- 20 % for the HS range Repeat accuracy +/- 2 % time delay Measurement error 0.5 %/C with temperature variation Cable distance between devices 100 m Sensitivity scale 0.25...5 kOhm LS (Low Sensitivity) 5...100 kOhm St (Standard Sensitivity) 50...1000 kOhm HS (High Sensitivity) Sensitivity adjustment 5...100 % Supply current for sensors <= 1 mA Cable capacitance <= 1 nF HS (High Sensitivity) probe cable <= 2.2 nF St (Standard Sensitivity) probe cable <= 4.7 nF LS (Low Sensitivity) Marking CE : 73/23/EEC CE : EMC 89/336/EEC Overvoltage category III conforming to IEC 60664-1 Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Insulation resistance > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 Ui rated insulation voltage 250 V conforming to IEC 60664-1 Operating position Any position without derating Connections - terminals Screw terminals 1 x 0.5...1 x 4 mm - AWG 20...AWG 11, solid cable without ca- ble end Screw terminals 2 x 0.5...2 x 2.5 mm - AWG 20...AWG 14, solid cable without cable end Screw terminals 1 x 0.2...1 x 2.5 mm - AWG 24...AWG 12, flexible cable with ca- ble end Screw terminals 2 x 0.2...2 x 1.5 mm - AWG 24...AWG 16, flexible cable with ca- ble end Tightening torque 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1 Housing material Self-extinguishing plastic Local signalling LED green power ON LED yellow relay ON LED yellow timer ON Mounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715 Electrical durability 100000 cycles Mechanical durability 30000000 cycles Operating rate <= 360 operations/hour under full load Safety reliability data MTTFd = 182.6 years B10d = 170000 Width 1.38 in (35 mm) Environment Immunity to microbreaks 100 ms DC 90 ms AC Electromagnetic compatibility Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 Standards EN/IEC 60255-6 Product certifications CSA C-Tick GL GOST UL Ambient air temperature for storage -40...158 F (-40...70 C) Ambient air temperature for operation -4...122 F (-20...50 C) Relative humidity 95 % at 131 F (55 C) conforming to IEC 60068-2-30 Vibration resistance 0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6 1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1 Shock resistance 15 gn 11 ms conforming to IEC 60255-21-1 Pollution degree 3 conforming to IEC 60664-1 Dielectric test voltage 2 kV AC 50 Hz, 1 min conforming to IEC 60255-5 2 kV AC 50 Hz, 1 min conforming to IEC 60664-1 Ordering and shipping details Category 22380 - RELAYS-MEASUREMENT (RM17-RM35) Discount Schedule CP2 GTIN 00785901565796 Nbr. of units in pkg. 1 Package weight(Lbs) 0.29999999999999999 2