Product data sheet RM35TF30 Characteristics Zelio, 3 phase supply control relay, range 220 to 480 VAC, sequence, phase failure, phase imbalance, voltage Product availability: Stock - Normally stocked in distribution facility Main Range of product Zelio Control Product or component Modular measurement and control relays type Relay type Multifunction control relay Product specific applica- For 3-phase supply tion Relay name RM35TF Relay monitored para- Phase failure detection meters Undervoltage and overvoltage in window mode Asymmetry Phase sequence Time delay Adjustable 0.1...10 s, +/- 10 % of the full scale value Switching capacity in 1250 VA VA Measurement range 208...480 V voltage AC Complementary Reset time <= 1500 ms at 480 V Maximum switching voltage 250 V AC 250 V DC Minimum switching current 10 mA at 5 V DC Maximum switching current 5 A AC 5 A DC Supply voltage limits 194...528 V AC, 3 phases Control circuit voltage limits - 12 % + 10 % Un Power consumption in VA 0...22 VA at 400 V AC 50 Hz Voltage detection threshold < 194 V Control circuit frequency 50...60 Hz +/- 10 % Output contacts 2 C/O Nominal output current 5 A Measurement voltage limits 176...528 V AC Hysteresis 2 % Delay at power up <= 650 ms Measuring cycle <= 140 ms measurement cycle as true rms value Threshold adjustment voltage +2...+10 % in the range 480 V AC -12...-2 % in the range 220 V AC 2...20 % of Un selected -20...-2 % in the range 380...480 V AC +2...+20 % in the range 220...440 V AC Voltage range 220...480 V phase to phase Adjustment of asymmetry threshold 5...15 % of Un selected Repeat accuracy 0.3 % time delay 0.5 % input and measurement circuit Measurement error < 1 % over the whole range with voltage variation 0.05 %/C with temperature variation Response time < 200 ms in the event of a fault Marking CE Overvoltage category III conforming to IEC 60664-1 Aug 10, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Insulation resistance > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 Ui rated insulation voltage 400 V conforming to IEC 60664-1 Supply frequency 50/60 Hz +/- 10 % Operating position Any position without Connections - terminals Screw terminals 1 x 0.5...1 x 4 mm - AWG 20...AWG 11, solid cable without ca- ble end Screw terminals 2 x 0.5...2 x 2.5 mm - AWG 20...AWG 14, solid cable without cable end Screw terminals 1 x 0.2...1 x 2.5 mm - AWG 24...AWG 12, flexible cable with ca- ble end Screw terminals 2 x 0.2...2 x 1.5 mm - AWG 24...AWG 16, flexible cable with ca- ble end Tightening torque 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1 Housing material Self-extinguishing plastic Local signalling LED green power ON LED yellow relay ON LED yellow fault Mounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715 Electrical durability 100000 cycles Mechanical durability <= 30000000 cycles Operating rate <= 360 operations/hour under full load Utilisation category AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 Safety reliability data MTTFd = 399.5 years B10d = 360000 Width 1.38 in (35 mm) Product weight 0.29 lb(US) (0.13 kg) Environment Electromagnetic compatibility Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to EN/IEC 61000-6-2 Standards EN/IEC 60255-1 Product certifications UL C-Tick GOST CSA GL Directives 89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive Ambient air temperature for storage -40...158 F (-40...70 C) Ambient air temperature for operation -4...122 F (-20...50 C) Relative humidity 95 % at 131 F (55 C) conforming to IEC 60068-2-30 Vibration resistance 0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6 1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1 Shock resistance 15 gn 11 ms conforming to IEC 60255-21-1 IP degree of protection IP20(Terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 Dielectric test voltage 2 kV 1 min AC 50 Hz Non-dissipating shock wave 4 kV 2