PS162 PS162/PS312 Ceramic Capacitive OEM High and Low Pressure Sensing Modules PS312 Typical Applications Industrial Pumps & Compressors Refrigeration Heating, Ventilation and Air-conditioning (HVAC) Description Steam Sterilizers, Boilers & Dryers Kavlicos OEM Pressure sensing modules Test & Monitoring Equipment utilize our more than 30-year field-proven Process Controls ceramic capacitive sensing technology and are Facility Management intended for high volume applications. Millions Mechanical Engineering of Kavlico sensors are installed worldwide Filter Restriction in a variety of industrial and transportation Fuel Cells applications. Hydraulics Systems Process Controls These RoHS compliant modules are Level Measurement equipped with a robust flush mounted ceramic Water Management sensing diaphragm that is compatible with Power Generators most industrial fluids and gaseous media. The standard housing material is a Brass Spacer, Standard Full Scale Pressure Ranges and the standard electrical connection is 3 Isolated Wires 0.15 mm, 2 75mm Long. PS162: 0-200 mBar up to 0-200 Bar The module allows for easy integration and PS312: 0-50 mBar up to 0-20 Bar installation into final assemblies for a wide Features variety of applications. Media Resistant With a 10-year minimum shelf life and a Superior Long-Term Stability & Repeatability lifetime of millions of pressure cycles, Kavlicos High Overpressure Capability ruggedly designed modules are made to last. Shock & Vibration Resistant Potsdamer Str. 14, 32423 Minden, Germany 235 E. Main St., Suite 102A, Northville, MI 48167, USA Tel: +49 571 3859-0 - Fax: +49 571 3859-119 Tel: +1 (248) 465-0815 - Fax: +1 (248) 465-0810 Email: info kavlico.de Email: pressure.sensors kavlico.com www.kavlico.comTechnical Specifications -------PS Module 312 -------- -------PS Module 162 -------- Pressure ranges from 0 to bar 0.05 up to 20 0.2 up to 100 Proof pressure bar 1.2 up to 60 2 up to 300 Burst pressure bar 2.4 up to 100 4 up to 400 Reference Absolute or gage Materials Wetted Parts Ceramic Al203, gold coating on diaphragm Process Media All gases and liquids compatible with ceramic Al203 and gold Electrical Supply Voltage 4.75 - 5.25 VDC Output Signal 1.0 - 4.0 VDC output 0.5 - 4.5 VDC output configuration at Zero 1.0 VDC 0.5 VDC at Full Span 4.0 VDC 4.5 VDC Supply current Max. 2.2 mA at 5 VDC Load resistance > 50 k Protection Overvoltage 7 VDC EMI Dependent upon customer packaging Response time 10 ms max. to 63 % of full scale pressure with step change on input Accuracy *) 0,5 % of span Non-linearity **) typ. 0.1 % of span Hysteresis 0,2 % of span Non-repeatability 0,1 % of span 1-year stability ***) typ. 0.1 % of span *) Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2) **) BFSL according to IEC 61298-2 ***) with reference conditions to EN 61298-1 Temperature Operating temperature range -40C to + 125C TC zero typ. 0.05 % / 10K TC span typ. 0.05 % / 10K Conformity RoHS according to 2002/95/EC RoHS Directive Electrical connection 3 isolated wires 0.15 mm, 75 mm long Color code of wires RED VSUPPLY, GREEN OUTPUT, BLACK GROUND Service life Min. 10 million pressure cycles full scale Weight PS312 40 gram PS162 20 gram Customized versions with PS modules already build into housings on request - contact factory for details. Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring conditions. Non-compliance can result in serious injury and/or damage to the equipment. Dont see what you want Call us at +49 571 3859-174 Warning: The product information contained in this catalogue is given purely as information and does not constitute to customize this product a representation, warranty or any form of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products to meet your application-specific needs and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic Kavlicos General Terms & Conditions apply and can be found at www.kavlico.com components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly 2013 Kavlico. All rights reserved. agreed by us prior to the sale of our products. Potsdamer Str. 14, 32423 Minden, Germany 235 E. Main St., Suite 102A, Northville, MI 48167, USA Tel: +49 571 3859-0 - Fax: +49 571 3859-119 Tel: +1 (248) 465-0815 - Fax: +1 (248) 465-0810 Email: info kavlico.de Email: pressure.sensors kavlico.com www.kavlico.com