DATA SHEET AS183-92/AS183-92LF: 300 kHz-2.5 GHz pHEMT GaAs SPDT Switch Applications General purpose medium-power switches in telecommunication applications Transmit/receive switches in 802.11 b/g WLAN Bluetooth systems Features IP1dB: +30 dBm typical 3 V IP3: +43 dBm typical 3 V Low insertion loss: 0.3 dB 0.9 GHz Low DC power consumption Figure 1. AS183-92/AS183-92LF Block Diagram Ultra-miniature, SC-70 (6-pin, 2.00 x 1.25 mm) package (MSL1, 260 C per JEDEC J-STD-020) Description The AS183-92/AS183-92LF is a pHEMT GaAs FET Single Pole Double Throw (SPDT) switch. The device features low insertion loss and positive voltage operation with very low DC power consumption. The AS183-92/AS183-92LF is manufactured in a compact, low-cost 2.00 x 1.25 mm, 6-pin SC-70 package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Figure 2. AS183-92/AS183-92LF Pinout 6-Pin SC-70 (Top View) Skyworks Solutions, Inc. Phone 781 376-3000 Fax 781 376-3100 sales skyworksinc.com www.skyworksinc.com 200177D Skyworks Proprietary Information Products and Product Information are Subject to Change Without Notice December 22, 2011 1 DATA SHEET AS183-92/AS183-92LF SPDT SWITCH Table 1. AS183-92/AS183-92LF Signal Descriptions Pin Name Description Pin Name Description 1 J2 RF input/output 2 (Note 1) 4 V2 DC control voltage 2 GND Ground 5 J1 RF input/output 1 (Note 1) 3 J3 RF input/output 3 (Note 1) 6 V1 DC control voltage Note 1: A 100 pF blocking capacitor is required for >500 MHz operation. Use larger value capacitors for lower frequency operation. Table 2. AS183-92/AS183-92LF Absolute Maximum Ratings Parameter Symbol Minimum Maximum Units Control voltage VCTL 0.2 +8.0 V RF input power (VCTL = 0 to 7 V) >500 MHz PIN 6 W Operating temperature TOP 40 +85 C Storage temperature TSTG 65 +150 C Note: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Electrical and Mechanical Specifications The state of the AS183-92/AS183-92LF is determined by the logic provided in Table 4. The absolute maximum ratings of the AS183-92/AS183-92LF are provided in Table 2. Electrical specifications are provided in Table 3. Performance characteristics for the AS183-92/AS183-92LF are illustrated in Figures 3 through 5. Skyworks Solutions, Inc. Phone 781 376-3000 Fax 781 376-3100 sales skyworksinc.com www.skyworksinc.com 2 December 22, 2011 Skyworks Proprietary Information Products and Product Information are Subject to Change Without Notice 200177D