DATA SHEET SKY13350-385LF: 0.01-6.0 GHz GaAs SPDT Switch Applications INPUT WLAN 802.11 a/b/g networks OUTPUT2 WLAN repeaters OUTPUT1 ISM band radios Low power transmit receive systems Features Positive voltage control (0/1.6 V to 0/5.0 V) VCTL1 VCTL2 S1481 Broadband frequency range: 0.01 to 6.0 GHz Figure 1. SKY13350-385LF Block Diagram Very low insertion loss, 0.35 dB typical 3 GHz High isolation, 25 dB typical 3 GHz Description Excellent linearity performance, IP0.5dB = +30 dBm with The SKY13350-385LF is a GaAs pHEMT FET single-pole, double- control voltage = 3 V throw (SPDT) switch. The switch may be used in transmit/receive Ultra-miniature, MLPD (6-pin, 1 x 1 mm) package (MSL1, applications by connecting the RF common port (INPUT, pin 6) to 260 C per JEDEC J-STD-020) either the OUTPUT1 or OUTPUT2 port (pin 2 or 4, respectively) using a low loss path (i.e., a positive voltage applied to either Skyworks Green products are compliant with VCTL1 or VCTL2 pins). The switch is reflective short on the all applicable legislation and are halogen-free. isolated port. For additional information, refer to Skyworks The switch is manufactured in a compact, 1 x 1 mm, 6-pin Denition of Green, document number exposed pad plastic Micro Leadframe Package Dual (MLPD) SQ04-0074. package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. 6 VCTL1 VCTL2 1 5 2 4 OUTPUT1 OUTPUT2 3 Figure 2. SKY13350-385LF Pinout 6-Pin MLPD (Top View) Skyworks Solutions, Inc. Phone 781 376-3000 Fax 781 376-3100 sales skyworksinc.com www.skyworksinc.com 201174I Skyworks Proprietary Information Products and Product Information are Subject to Change Without Notice September 19, 2018 1 GND INPUTDATA SHEET SKY13350-385LF SPDT SWITCH Table 1. SKY13350-385LF Signal Descriptions Pin Name Description Pin Name Description 1 VCTL1 DC control voltage 4 OUTPUT2 RF port. Must be DC blocked. 2 OUTPUT1 RF port. Must be DC blocked. 5 VCTL2 DC control voltage 3 GND Ground 6 INPUT RF port. Must be DC blocked Table 2. SKY13350-385LF Absolute Maximum Ratings Parameter Symbol Minimum Typical Maximum Units Input power PIN >500 MHz, 5 V +32 dBm >500 MHz, 3 V +31 dBm Storage temperature TSTG 65 +150 C Operating temperature TOP 40 +105 C Note: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Table 3. SKY13350-385LF Recommended Operating Conditions Parameter Symbol Minimum Typical Maximum Units Frequency f 0.01 6.0 GHz Control voltage: low VCTL L 0 0.2 V high VCTL H 1.6 5.0 V Operating temperature TOP +25 C Typical performance characteristics of the SKY13350-385LF are Electrical and Mechanical Specifications illustrated in Figures 3 through 9. The absolute maximum ratings of the SKY13350-385LF are provided in Table 2. The recommended operating conditions are The state of the SKY13350-385LF is determined by the logic specified in Table 3 and electrical specifications are provided in provided in Table 5. Table 4. Skyworks Solutions, Inc. Phone 781 376-3000 Fax 781 376-3100 sales skyworksinc.com www.skyworksinc.com 2 September 19, 2018 Skyworks Proprietary Information Products and Product Information are Subject to Change Without Notice 201174I