CINT1150 150W Single Output Industrial Series Features 2 x 4 x 1.3 Package For 1U Applications 150W w/air, 100W convection cooled Universal Input 90-264 VAC Power Fail/Output Good Signal Approved to EN/CSA/IEC/UL62368-1 3 Year Warranty RoHS Compliant Description The CINT1150 family is the latest offering in high density single output open-frame AC/DC power supplies. Approved to EN/IEC/UL60950-1, 2nd edition, the CINT1150 family is ideal for lighting, industrial printers, gaming equipment, and many other applications where power density and cost are critical. The CINT1150 operates at universal input range of 90 to 264Vac and wide temperature range -10C to +70C, delivering full rated output power up to +50C. In addition, these models feature Power Fail and DC OK signals. Model Selection Model Output Current Ripple & Total OVP Number Volts w/200LFM air Convection* Noise** Regulation Threshold*** CINT1150A1206K01 12V 12.5A 8.33A 0.5%RMS, 1.2% pk-pk 5% 14.0 1.1V CINT1150A2406K01 24V 6.25A 4.17A 0.5%RMS, 1.0% pk-pk 5% 28.0 2.5V CINT1150A4806K01 48V 3.13A 2.08A 0.5%RMS, 1.0% pk-pk 5% 55.0 4.0V CINT1150A5606K01 56V 2.68A 1.79A 0.5%RMS, 1.0% pk-pk 5% <59.9V Notes: * Maximum output power is 95 Watts for input voltage of 90-105VAC at 50C convection. For input voltage of 105Vac or more, the total power is 100 Watts at 50C convection. ** Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors. General Specifications Less than 2 sec. 115Vac (inversely 100-240Vac, 10%, 47-63Hz, 1 AC Input Turn On Time proportional to input voltage and thermistor 120370Vdc temperature) Input Current 115Vac: 2A, 230Vac: 1A Hold-up Time >12mS at full load, 120Vac 264Vac, cold start: will not exceed 50A AC Power Fail, DC OK Inrush Current Signals F1, F2: 4A, 250Vac fuses provided on all Overload Input Fuses Hiccup Mode models Protection www.slpower.com 1 CINT1150 REV 2.8, V1220 CINT1150 150W Single Output Industrial Series General Specifications (continued) Earth Leakage Short Circuit Provided - no damage will occur if the output <750A 264Vac, 60Hz, NC is shorted. Hiccup Mode Current Protection OVP firing reduces output voltage to <50% Overvoltage Efficiency 88% typical at 115Vac of nominal in <50mS. See chart for trip Protection range. 150W continuous with 200 lfm airflow, 100W PFC: Variable 30-400kHz. Output Power convection cooled See chart for specific Switching Frequency Main Converter: Variable 35-180kHz, 65- voltage model ratings. 70kHz at full load. Input-Output: 4000Vac Transient 50% load step. i/t: <0.2A/S Isolation Input-Ground: 1800Vac Max Volt Deviation = 3% Response Output-Ground: 500Vac Operating -10C to +70C Ripple and Noise See chart -40C Start Up Temperature Temperature Derate output power linearly above 50C to See chart Output Voltage 50% at 70C Derating Voltage +/-5% from nominal Storage Temperature -40C to +85C Adjustability Operating: -500 to 10,000 ft Minimum Load Not required Altitude Non-operating: -500 to 40,000 ft. +/- 5%. See chart 5% to 95%, non-condensing Total Regulation Relative Humidity Operating: 0.003g/Hz, 1.5grms overall, 3 Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 axes, 10 min/axis shocks total Vibration Shock Non-Operating: 0.026g2/Hz, 5.0grms overall, Non-Operating: Half-sine, 40 gpk, 10 ms, 3 3 axes, 1 hr/axis axes, 6 shocks total Dimensions W: 2.0 x L: 4.0 x H: 1.3 Safety Standards EN/CSA/IEC/UL62368-1 640,000 hours at 100W convection, Weight 183g MTBF 1,500,000 hours at 150W with 200LFM air Auxiliary Signals Goes LOW with 5 mS warning before loss AC Power Fail: During normal operations, stays HIGH. Power Fail: of output power due to AC failure Open collector logic signal goes and stays HIGH DC OK: 100mS to 500mS after main output reaches regulation. www.slpower.com 2 CINT1150 REV 2.8, V1220