200W Single Output 200W Single Output CINT1200 Family CINT1200 Family Industrial Grade Industrial Grade FEATURES AND BENEFITS 3 x 5 x 1.3 Package Approved to EN/CSA/IEC/UL62368-1 Industrial 200W with 100LFM Air Efficiency 90% Typical 3 Years Warranty 180W Convection Cooled Fits 1U Applications Universal Input 90-264 VAC Class B Conducted EMI RoHS Compliant MODEL SELECTION Output Current Minimum Total OVP Ripple & Model Number Volts * ** *** w/100LFM air Convection Load Regulation Threshold Noise CINT1200A1275K01 16.7A 15.0A 0A 120mV pk-pk 3% 14.0 1.1V 12V 13.3A 12.0A 0A 150mV pk-pk 3% 18.5 1.2V CINT1200A1575K01 15V CINT1200A1875K01 18V 11.1A 10.0A 0A 180mV pk-pk 3% 21.5 2.0V 24V 8.33A 7.50A 0A 240mV pk-pk 3% 29.0 2.5V CINT1200A2475K01 CINT1200A2875K01 28V 7.14A 6.40A 0A 280mV pk-pk 3% 33.5 2.5V CINT1200A3275K01 32V 6.25A 5.62A 0A 320mV pk-pk 3% 36.0 3.0V CINT1200A3675K01 36V 5.55A 5.00A 0A 360mV pk-pk 3% 41.0 3.0V CINT1200A4875K01 48V 4.17A 3.75A 0A 480mV pk-pk 3% 56.0 3.0V Notes : * Total convection power is 180 Watts. ** Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors. INPUT OUTPUT AC Input 100-240VAC, 10%, 47-63Hz, 1 Hold-up Time 16ms at 200W, 120VAC/60Hz 120-370V DC Turn On Time Less than 3sec 115VAC, Full Load Input Current 115VAC: 1.8A, 230VAC: 0.9A PFC: Fixed, 65kHz Switching Frequency 264VAC, Cold start: will not exceed 55A Main Converter: Variable 35-200kHz, 65-70kHz at Inrush Current full load Input Fuses F1, F2: 3.15A, 250VAC fuses provided on all models 200W continuous, with 100 lfm airflow, 180W convection cooled - See chart for specific voltage Output Power Earth Leakage <500A 264VAC, 60Hz, NC <1mA SFC model ratings Current Output Voltage See chart Efficiency 88% typical Ripple and Noise 0.5%rms, 1% pk-pk, see chart 500S typical, Return to 0.5% of nominal, 50% load Transient Response step Di/Dt: <0.2A/S. Max voltage deviation = 3% ISOLATION SPECIFICATIONS Voltage Adjustability Fixed Output Input-Output: 4,000VAC Minimum Load Not required Input-Ground: 1,800VAC Isolation Output-Ground: 1,500VAC Total Regulation +/- 3% combined line, load and initial setting CINT1200 Datasheet v0920 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 1 200W Single Output 200W Single Output CINT1200 Family CINT1200 Family Industrial Grade Industrial Grade PROTECTION SAFETY Overtemperature Sensing transformer temperature, 165C at full load, Safety Standards EN/CSA/IEC/UL62368-1 latching type, requires input power recycling to reset Protection Operating: Half-sine, 20gpk, 10ms, 3 axes, Overload Protection 120 to 150% of rating, Hiccup mode 6 shocks total Shock Non-operating: Half-sine, 40 gpk, 10ms, 3 axes, Short Circuit 6 shocks total Hiccup mode, Auto recovery Protection Overvoltage OVP latch, see models chart for trip range Protection RELIABILITY MTBF 401,000 hours, 25C, 110VAC ENVIRONMENT -10C to +70C Operating Temperature Start up at -40C, Full load Temperature Derating Derate output power linearly above 50C to 50% at 70C Storage Temperature -40C to +85C Operating: -500 to 10,000 ft Altitude Non-operating: -500 to 40,000 ft Relative Humidity 5% to 95%, Non-condensing Operating: 0.003g/Hz, 1.5grms overall, 3axes, 10 min/axis Vibration Non-operating: 0.026g/Hz, 5.0grms overall, 3 axes, 1 hr/axis Dimensions W: 3.0 x L: 5.0 x H: 1.3 Weight 325g DERATING CURVE 180W convection cooled and 200W continuous with 100 LFM airflow, derate output power to 50% at 70C. Output Power vs. Temperature 250 200 150 Convection 200 LFM Cooling 100 50 0 -10 0 10 20 30 40 50 60 70 CINT1200 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. CINT1200 Datasheet v0920 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 2 Output Power (W)