200W Single Output 200W Single Output
CINT1200 Family CINT1200 Family
Industrial Grade Industrial Grade
FEATURES AND BENEFITS
3 x 5 x 1.3 Package Approved to CSA/EN/IEC/UL60950-1, 2nd
Industrial
Edition
200W with 100LFM Air
Efficiency 90% Typical
180W Convection Cooled
3 Years Warranty
Fits 1U Applications
Universal Input 90-264 VAC
Class B Conducted EMI
RoHS Compliant
MODEL SELECTION
Output Current Minimum Total OVP
Ripple &
Model Number
Volts
* ** ***
w/100LFM air Convection Load Regulation Threshold
Noise
CINT1200A1275K01 16.7A 15.0A 0A 120mV pk-pk 3% 14.0 1.1V
12V
13.3A 12.0A 0A 150mV pk-pk 3% 18.5 1.2V
CINT1200A1575K01 15V
CINT1200A1875K01 18V 11.1A 10.0A 0A 180mV pk-pk 3% 21.5 2.0V
24V 8.33A 7.50A 0A 240mV pk-pk 3% 29.0 2.5V
CINT1200A2475K01
CINT1200A2875K01 28V 7.14A 6.40A 0A 280mV pk-pk 3% 33.5 2.5V
CINT1200A3275K01 32V 6.25A 5.62A 0A 320mV pk-pk 3% 36.0 3.0V
CINT1200A3675K01 36V 5.55A 5.00A 0A 360mV pk-pk 3% 41.0 3.0V
CINT1200A4875K01 48V 4.17A 3.75A 0A 480mV pk-pk 3% 56.0 3.0V
Notes : * Total convection power is 180 Watts.
** Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors.
INPUT OUTPUT
AC Input 100-240VAC, 10%, 47-63Hz, 1 Hold-up Time 16ms at 200W, 120VAC/60Hz
120-370V DC
Turn On Time Less than 3sec @ 115VAC, Full Load
Input Current 115VAC: 1.8A, 230VAC: 0.9A
PFC: Fixed, 65kHz
Switching Frequency
264VAC, Cold start: will not exceed 55A Main Converter: Variable 35-200kHz, 65-70kHz at
Inrush Current
full load
Input Fuses
F1, F2: 3.15A, 250VAC fuses provided on all models
200W continuous, with 100 lfm airflow, 180W
convection cooled - See chart for specific voltage
Output Power
Earth Leakage
<500A @ 264VAC, 60Hz, NC; <1mA SFC
model ratings
Current
Output Voltage
See chart
Efficiency
88% typical
Ripple and Noise 0.5%rms, 1% pk-pk, see chart
500S typical, Return to 0.5% of nominal, 50% load
Transient Response
step Di/Dt: <0.2A/S. Max voltage deviation = 3%
ISOLATION SPECIFICATIONS
Voltage Adjustability Fixed Output
Input-Output: 4,000VAC
Minimum Load Not required
Input-Ground: 1,800VAC
Isolation
Output-Ground: 1,500VAC
Total Regulation
+/- 3% combined line, load and initial setting
CINT1200 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. Page 1 200W Single Output 200W Single Output
CINT1200 Family CINT1200 Family
Industrial Grade Industrial Grade
PROTECTION SAFETY
Overtemperature Sensing transformer temperature, 165C at full load, Safety Standards EN/CSA/UL/IEC 60950-1, 2nd edition
latching type, requires input power recycling to reset
Protection
Operating: Half-sine, 20gpk, 10ms, 3 axes,
Overload Protection 120 to 150% of rating, Hiccup mode 6 shocks total
Shock
Non-operating: Half-sine, 40 gpk, 10ms, 3 axes,
Short Circuit
6 shocks total
Hiccup mode, Auto recovery
Protection
Overvoltage
OVP latch, see models chart for trip range
Protection
RELIABILITY
MTBF
401,000 hours, 25C, 110VAC
ENVIRONMENT
-10C to +70C
Operating Temperature
Start up at -40C, Full load
Temperature Derating Derate output power linearly above 50C to 50% at 70C
Storage Temperature -40C to +85C
Operating: -500 to 10,000 ft
Altitude
Non-operating: -500 to 40,000 ft
Relative Humidity 5% to 95%, Non-condensing
Operating: 0.003g/Hz, 1.5grms overall, 3axes, 10 min/axis
Vibration
Non-operating: 0.026g/Hz, 5.0grms overall, 3 axes, 1 hr/axis
Dimensions W: 3.0 x L: 5.0 x H: 1.3
Weight 325g
DERATING CURVE
180W convection cooled and 200W continuous with 100 LFM airflow, derate output power to 50% at 70C.
Output Power vs. Temperature
250
200
150
Convection
200 LFM Cooling
100
50
0
-10 0 10 20 30 40 50 60 70
CINT1200 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. CINT1200 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. Page 2
Output Power (W)