40W Single Output 40W Single Output GB40 Family GB40 Family Medical & Industrial Grade Medical & Industrial Grade FEATURES AND BENEFITS rd 40W Open Frame and PCB-mount Power Supply Approved to CSA/EN/IEC/UL60601-1, 3 Edition Medical 2.0 x 4.0 x 1.0 Package E-cap Life of >8 Years Universal Input 90-264VAC >1,000,000 Hours MTBF <0.1W No Load Input Power 3 Year Warranty Industrial Approved to CSA/EN/IEC/UL62368-1 Meets Class B Radiated & Conducted EMI, with Margin th Meets Heavy Industrial and IEC60601-1-2 4 Edition Levels of EMC Note: *Consult Factory for compliance information. MODEL SELECTION Rated Output Ripple & Line Load Input Output 2 Model Number Volts 1 Current Power Noise Regulation Regulation Class/Termination Termination Class I (Grounded) input, 75mV pk-pk GB40S05K01 5.0V 5.0A 25W 1% 5% -pin AMP/Molex type 4-pin AMP/Molex type GB40S09K01 9.0V 4.0A 36W 90mV pk-pk 1% 5% connector 2 connector for K and C Change K to C for versions GB40S12K01 12.0V 3.4A 40W 120mV pk-pk 1% 5% class II input 120mV pk-pk GB40S18K01 18.0V 2.22A 40W 1% 5% Change K to P for PCB mount pins, class I input PCB mount pins for 240mV pk-pk GB40S24K01 24.0V 1.7A 40W 1% 5% P and V versions Change K to PCB mount pins, class II input 480mV pk-pk GB40S48K01 48.0V 0.83A 40W 1% 5% Note: 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 2. Other output voltages available, consult factory. 3. All specifications are typical at 230VAC, full load, at 25C ambient unless noted. INPUT OUTPUT Input Voltage and <700ms Turn On Time 100-240VAC, 10%, 47-63Hz, 1 Frequency Hold-Up Time 20ms/100VAC at full load Input Current 115VAC: 1.2A, 230VAC: 0.6A 25W-40W continuous See models chart for specific Output Power 264VAC, cold start: will not exceed 40A peak Inrush Current voltage model ratings Input Fuses 3.15A, 250VAC fuse in both line and neutral Output Voltage See models chart Earth Leakage Current 00240 500 s resp. time for return to w/in 0.5% of final (Input to Ground) 240 value for any 50% load step from 5% to 100% of Transient Response 02 Earth Leakage Current 00240 Max voltage deviation is +/-3.5% (Output to Ground) 00240 Regulation See models chart Efficiency >88%, typical Note: All specifications are typical at 230VAC input, full load, at 25C ambient unless noted. 0.9, min., 230VAC, 80-100% load vector, 25C Power Factor ambient Note: All specifications are typical at 230VAC input, full load, at 25C ambient unless noted. GB40 Datasheet v0420 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 1 40W Single Output 40W Single Output GB40 Family GB40 Family Medical & Industrial Grade Medical & Industrial Grade PROTECTION SAFETY Overtemperature Will shutdown upon an overtemperature condition, ITE/Industrial Safety EN/IEC/UL62368-1 Protection Auto-recovery rd Medical Safety EN/IEC/UL60601-1, 3 edition 130% to 160% of rated output current value, Overload Protection Hiccup mode Hiccup mode Short Circuit Protection EMI/EMC COMPLIANCE 120% to 150% of nominal output voltage, Overvoltage Protection Hiccup Mode EN55032, EN55011/CISPR11 Class B, FCC Part Conducted Emissions 15.107, Class B: 6db margin type, at 115 and 230VAC EN55032, EN55011/CISPR11 Class B, FCC Part RELIABILITY Radiated Emissions 15.109, Class B: 3db margin type, at 115 and 230VAC Electro-Static Discharge EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, >1,000,000 hours, full load, 110 & 220VAC input, MTBF (ESD) Immunity on +/- 15kV air, Criteria A 25C amb., per telcordia 332 issue 6, stress method th Power Ports IEC60601-1-2, 4 edition, Table 4 >8 year life based on calculations at 115VAC/60Hz EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, E-cap Life & 230VAC/50Hz, ambient 25C at 24 hrs per day, Radiated RF EM Fields 80% AM at 1kHz 365 days/year, 6 power up cycles per day Susceptibility th IEC60601-1-2, 4 edition, Table 4 EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, Electrical Fast 100Khz rep rate, 40A, Criteria A ISOLATION SPECIFICATIONS Transients (EFT)/Bursts th IEC60601-1-2, 4 edition, Table 5 Input-Output : 4000VAC (2 MOPP) Surges, Line to Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, Input-Ground : 1500VAC (1 MOPP) Isolation (Diff Mode) and Line to +/-4kV CM, Criteria A th Output-Ground : 1500VAC (1 MOPP) GND (CMN Mode) Surpasses IEC60601-1-2, 4 edition requirements Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: TBD EN55022/IEC61000-4-6, 3.6V/m Level 4, (0.15 to Conducted Disturbances 80Mhz and 12V/m) in ISM and amateur radio bands Induced by RF Fields between 0.15Mhz and 80Mhz, 80% AM at 1KHz th IEC60601-1-2, 4 edition, Table 5 ENVIRONMENT Rated Power Frequency EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60Hz th Magnetic Fields IEC60601-1-2, 4 edition, Table 4 -25 ~ +70C, see derating curve for operation above Operating Temperature 60C EN55024/IECEN61000-4-11: --100% dip for 10ms, at 0, 45, 90, 135, 180, 225, StorageTemperature -40C ~ +85C 270 and 315 degrees, 100% dip for 20ms, 0 deg., Cooling Convection Voltage Interruptions, Criteria A Dips, Sags & Surges --100% dip for 5000 ms (250/300 cycles), Criteria B Relative Humidity 5% to 90%, Non-condensing --60% dip for 100ms, Criteria B --30% dip for 500ms, Criteria A Operating: 0.003g/Hz, 1.5grms overall, 3 axes, th IEC60601-1-2, 4 edition, Table 5 10 min/axis, 1-500Hz Non-Oper.: random waveform, 3 minutes per axis, 3 Harmonic Current Vibration EN55011/EN61000-3-2, Class A axes and sine waveform, vib. frequency/acceleration: Emissions 10-500Hz/1g, sweep rate of 1 octave/minutes, vibration time of 10 sweeps/axes, 3 axes Flicker Test EN61000-3-3 Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks Note: 1. The power supply is considered a component which will be installed into a final equipment. total The final equipment must be re-confirmed that it still meets EMC directives. Shock 2. All specifications are typical at nominal input, full load, at 25C ambient unless noted. Consult Non-Operating: Half-sine waveform, impact factory for information regarding testing for or usage under special environments. acceleration of 50G, pulse duration of 6ms, Number of shocks: 3 for each of the three axis 48.3 x 101.6 x 25mm 2.0 x 4.0 x 0.97 inch (Height is from top of tallest Dimensions component to max. component pin protrusion on the bottom) Weight 110g Note: Same dimensions for PCB & Pin Variants. GB40 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. GB40 Datasheet v0420 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 2