GPC225 Commercial/GPM225 Medical
225 Watt Global Performance Switchers
FEATURES:
Wide-range ac input 85-264 Vac
2-year warranty
Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
Commercial Approved to UL1950, IEC950 and
CSA22.2-234 L3
Medical Approved to UL2601-1, IEC601-1 and
CSA22.2 No. 601
marked to LVD
SPECIFICATIONS:
Ac Input
85-264 Vac, 47-63 Hz single phase.
line impedance and distortion. Other settings are avail-
able to the user through adjustment of built-in potentiometer.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated
Output Noise
output load: 5.5 A
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output
Hold-Up Time
terminals of the power supply.
20 ms minimum from loss of ac input at full load, nominal
line (115 Vac).
Transient Response
500 s typical response time for return to within 0.5% of
Output Power
final value for a 50% load step change. i/ t<0.2 A/s.
175 W convection; 225 W with 26 cfm air; 250 W peak. Peak
Maximum voltage deviation is 3.5%. Startup/shutdown
ratings are for 60 s maximum duration, 10% duty cycle.
overshoot less than 3%.
Overload Protection
Remote Sense
Fully protected against short circuit and output overload.
Provided as a standard feature.
Short circuit protection is cycling type power limit.
Recovery after fault is automatic. Factory set to begin
Voltage Adjustment
power limiting at approximately 250 W.
Built-in potentiometer adjusts voltage 5%.
Overvoltage Protection
EMI/EMC Compliance
124% 12% typical.
All models include built-in EMI filtering to meet the
following emissions requirements:
Efficiency
EMI SPECIFICATIONS COMPLIANCE LEVEL
70% at full rated load, nominal input voltage, depending
Conducted Emissions GPC225 EN55022 Class B; FCC Class B
on model and load distribution.
Conducted Emissions GPM225 EN55011 Class B; FCC Class B
Static Discharge EN61000-4-2, 6 kV contact, 8 kV air
Input Protection
RF Field Susceptibility EN61000-4-3, 3 V/meter
Internal ac fuse provided. Designed to blow only if a
Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz
catastrophic failure occurs in the unit.
Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
Inrush Current
Commercial Leakage Current
Inrush is limited by internal thermistors. Inrush at 240 Vac
0.95 mA 254 Vac @ 60 Hz input (with no deviations).
under cold start conditions will not exceed 60 A.
Commercial Safety
Temperature Coefficient
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950,
0.03%/C typical on all outputs. EN60950 and CISPR22. UL file #E135803 commercial;
CSA #LR46516. The output(s) are intended for safety
Thermal Shutdown earthed Signal Output and Intermediate Circuits only. All
Provided as a standard feature. Designed to protect unit dc outputs are SELV under normal and single fault
from prolonged over temperature. conditions.
Environmental Medical Leakage Current
Designed for 0 to 50C operation at full rated output 60 A. 254 Vac @ 60Hz input.
power; derate output current and total output power by
2.5% per C above 50C. See Environmental and Medical Safety
Packaging Specifications on next page. Approved to UL2601, CSA22.2 No. 601 Level 3 and
IEC601. UL file E116994; CSA #LR46516. The output(s)
Power Fail are intended for safety earthed Signal Output and
TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms Intermediate Circuits only. The output(s) are not accept-
before output voltage drops more than 4% below nominal able for patient connection without additional isolation. All
voltage upon loss of ac power. The signal is factory set to dc outputs are SELV under normal and single fault
trip on 84 to 94 Vac brown-out depending upon incoming conditions.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com
66GPC225 Commercial/GPM225 Medical 225 Watt Multiple Output
Commercial Medical Output Output Output
Model Model Output Minimum Maximum (B) Maximum (C) Peak Noise P-P Total Regulation (A)
GPC225-5 GPM225-5 5AV 0A3A4 4A0 4V5 5%0 m 2
GPC225-12 GPM225-121A2 V 0A1A5.8 1A9 2V0 1%20 m 2
GPC225-15 GPM225-151A5 V 0A1A2.7 1A5 1V6 1%50 m 2
GPC225-24 GPM225-242A4 V 0A8A.3 9A.4 1V0 2%40 m 2
GPC225-28 GPM225-282A8 V 0A7A.1 8A8V.5 2%80 m 2
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Unrestricted natural convection cooling.
C. Requires 26cfm moving air.
GPC225/GPM225 MECHANICAL SPECIFICATIONS
Environmental
Operating Non-operating
Specification
o
Tsemperature (A)S5ee individual spec -40 to +8 C
HHumidity (A)0Hto 95% R 0 to 95% R
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power.
Sghock (B) 20 40 g
pk pk
B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
Atltitude-t500 to 10,000 f -500 to 40,000 f
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes,
2 2
Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz
total 6 shocks.
rms rms
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com
67