GSC25 Commercial/GSM25 Medical 25 Wtat Goblal Performance S Witcher S GLOBAL PERFORMANCE SWITCHERS Features: D C P o w e r S u p p l i e s Industrys smallest 25 W switcher 2.50 x 4.25 x 0.86 Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Overvoltage protection standard Commercial Approved to UL1950, CSA-C22.2 No.950, EN60950 Medical Approved to UL2601-1, IEC60601-1 EN60601-1 and CSA-C22.2 No. 601-1 RoHS Compliant (G suffix) marked to LVD SPECIFICATIONS Ac Input Inrush Current 90-264 Vac, 47-63 Hz single phase. Inrush is limited by internal thermistor. The inrush at 230 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 32 A. Input Current Maximum input current at minimum 120 Vac, 60 Hz with full rated output Temperature Coefficient load is 0.6 A. 0.03%/C typical on all outputs. Hold-up Time Environmental 15 ms minimum from loss of ac input at full load, nominal line (120 Vac). Designed for 0 to 50C operation at full rated output power derate output current and total output power by 2.5% per C between 50 - 70C. See Environmental and Output Power Packaging Specifications on next page. Normal continuous output power is 25 W, 28 W peak for 60 sec. maximum duration, 10% duty cycle. Factory set to begin power limiting at approxi- EMI/EMC Compliance mately 30 W. All models include built-in EMI filtering to meet the following emissions require - ments: Output Regulation Regulation from initial setpoint measured by changing load from 5% load to EMI SPECIFICATIONS COMPLIANCE LEVEL 50% load or 50% load to full load in either direction. Initial setpoint tolerance Conducted Emissions GSC25 EN55022 Class B FCC Class B is measured at 50% load. A minimum load of 5% of the output current on the Conducted Emissions GSM25 EN55011 Class B FCC Class B +5.1 V output (125 mA) is required to maintain proper regulation. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Overload Protection Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Fully protected against short circuit and output overload. Short circuit protec- Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. tion is cycling type power limit Commercial Safety: Output Noise Condor D.C. Power Supplies, Inc. declares under our sole responsibility that all GSC 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with models are in conformity with the applicable requirements of EN60950 following scope probe directly across output terminals of the power supply with load the provisions of the Low Voltage Directive 73/23/EEC. All GSC models are ap- terminated with 0.1 uF capacitor. proved to UL1950, CSA-C22.2 No.950, EN60950. Transient Response GSM25 Medical Model Earth Leakage Current Main output: 750 s typical response time for return to within 0.5% of final Leakage current measured in the Gnd wire connection when measured per value for a 50% load step within the regulation limits of minimum and maxi- UL2601-1 or IEC60601-1 is as follows: mum load, l/t <0.2 A/s. Maximum voltage deviation is 3.5%. Startup/shut - down overshoot less than 2%. Model Normal Fault Test Test Leakage Leakage Voltage Method Overvoltage Protection GSM25 50 A 78 A 132 Vca/60 Hz UL2601-1 Built in with firing point set per ratings table. OVP firing reduces voltage to less than 50% of nominal voltage in 50 ms. GSM25 94 A 150 A 264 Vca/50 Hz IEC60601-1 Voltage Adjustment Medical Safety Factory set with fixed resistors to maximize reliability. Condor D.C. Power Supplies, Inc. declares under our sole responsibility that all GSM models are in conformity with the applicable requirements of UL2601-1 Efficiency Patient Care Equipment, CSA-C22.2 No.601.1, IEC60601-1, EN 60601-1. 70% minimum at full rated load, nominal input voltage. Input Protection Internal ac fuse provided on all units. O All specifications are typical at nominal input, full load at 25 C unless otherwise statedLoad Commercial Medical Initial Setpoint OVP Ripple and Model Model Output No. Output Current Regulation Tolerance Setting Noise Notes GSC25A GSM25A 1 + 5.1 V 2.5 A 1% 1% 6.2 0.6 V 1% A 2 +12 V 1.5 A 4% 3% 1% A 3 - 12 V 0.2 A 1% 4% 1% B GSC25B GSM25B 1 + 5 V 2.5 A 1% 1% 6.2 0.6 V 1% A 2 +15 V 1.5 A 4% 3% 1% A 3 - 15 V 0.2 A 1% 4% 1% B GSC25D GSM25D 1 +5.1 V 2.5 A 1% 1% 6.2 0.6 V 1% A 2 +24 V 1.0 A 4% 3% 1% A 3 -12 V 0.2 A 1% 4% 1% B A. To maintain proper regulation on output 2, +5.1 V current must be at least 14 and not greater than 5 times V2 current. V1 must be adjusted within 1% of 5.1 V to maintain full load regulation on V2. B. Thermal foldback type current limit C. Add G suffix to model number for RoHS compliant model. GSC25/GSM25 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING Temperature (A) See individual specs. -40 to +85C A. Units should be allowed to warm up/operate under Humidity (A) 0 to 95% RH 0 to 95% RH non-condensing conditions before application of power. Shock (B) 20 g 40 g pk pk B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, total 6 shocks. Altitude -500 to 10,000 ft -500 to 40,000 ft C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and rms rms 1 hr./axis non-operating. SL Power Electronics Corp. 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info slpower.com Rev. 4/22/08. Data Sheet 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power Electronics accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.