GSM15 Medical 15 Watt Global Performance Medical Switcher GLOBAL PERFORMANCE SWITCHERS FEATURES: D C P o w e r S u p p l i e s Industrys smallest 15 W medically approved switcher Compact size (3.00 x 2.10 x 0.92) Wide-range ac input: 90-264 Vac Less than 75 A leakage current 120 Vac Approved to UL2601-1, EN60601-1 EMI to FCC, CISPR 11 Class B Overvoltage protection standard RoHS compliant models available (G suffix) marked to LVD SPECIFICATIONS Ac Input Temperature Coefficient 90-264 Vac, 47-63 Hz single phase. Class I or class II grounding. 0.03% / C typical. Input Current EMI/EM Compliance Maximum input current at 90 Vac, 60 Hz with full rated output load not to All models include built-in EMI filtering to meet the following EMC requirements of IEC601-1-2. exceed 0.6 A. Performance Requirement EMC Standard Typical Margin Input Protection Internal ac fuse provided on all units. Designed to blow only if a catastrophic Conducted Emissions EN55011, Class B FCC Class B 2 dB Class II Gnd failure occurs in the unit -- Fuse does not blow on unsustained overload or 6 dB Class I Gnd short circuit. Surge Discharge EN61000-4-2, Level 3 2 kV Inrush Current RF Field Susceptibility EN61000-4-3, Level 3 2 V Inrush is limited by internal thermistors. The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A. Fast Transients/Bursts EN61000-4-4, Level 3 500 V Efficiency Surge Susceptibility EN61000-4-5, Level 3 500 V 69-85% depending on model. Conducted RF Susceptibility EN61000-4-6 25% Overload Protection Voltage Sags & Surges EN61000-4-11 5% Fully protected against short circuit and output overload. Short circuit protec- tion is cycling type power limit. Factory set to begin power limiting at 23 W. Medical Safety Approvals All models are Certified to be in compliance with the applicable requirements of Overvoltage Protection UL2601-1, IEC60601-1, CSA-C22.2 No. 601-1, EN60601-1. Built in OVP on all models. Approximately 120-140% of output voltage. Leakage Current Output Noise The maximum leakage current for GSM15 series will be as follows 0.5% rms, 1% Pk-Pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. 132Vac/60Hz UL2601-1 test method Transient Response GND Connection Single Fault Main Output - 500 s max. response time for return to within 0.5% of final Normal value for a 50% load step change, i/ t< 0.2 A/s. Maximum voltage devia - Class I 75 A 105 A tion is 3.5%. Class II 39 A 54 A Hold-up Time 10 ms minimum from loss of ac input voltage at full load, nominal line (120 264Vac/50Hz IEC60601-1 test method Vac). GND Connection Single Fault Normal Class I 128 A 180 A Class II 66 A 94 A O All specifications are typical at nominal input, full load at 25 C unless otherwise statedMedical Voltage Initial Set Total Ripple and Model Output Min. Normal (A) Peak (B) Point OVP Setpoint Regulation Noise GSM15-5 5.1 V 0 A 2.35 A 3 A 2.5% 7.2 V 2% 1% GSM15-12 12 V 0 A 1.25 A 1.5 A 2.5% 16 V 2% 1% GSM15-15 15 V 0 A 1.0 A 1.2 A 2.5% 21 V 2% 1% GSM15-24 24 V 0 A 0.625 A 0.75 A 2.5% 32 V 2% 1% GSM15-28 28 V 0 A 0.54 A 0.64 A 2.5% 280 V 2% 1% Notes: A. Rating with unrestricted convection cooling. B. Peak Power for 60 sec. 10% duty cycle or continuous rating with 150 LFM of airflow. C. Output voltages preset at factory, not user adjustable. D. Add G suffix to model nuber for RoHS compliant model. GSM15 MECHANICAL SPECIFICATIONS INPUT: J1 AMP P/N 640456-4 PIN 1) AC LINE PIN 2) N/C PIN 3) N/C PIN 4) AC NEUTRAL GND: 0.098 DIA. THRU HOLE OUTPUT: J2 AMP P/N 640456-4 PIN 1) COMMON Return PIN 2) COMMON Return PIN 3) OUTPUT 1 + Vout PIN 4) OUTPUT 1 +Vout MATING CONNECTOR AMP P/N MTA 100 Recepticle NOTE: 3A MAXIMUM RECOMMENDED CURRENT PER CONNECTOR PIN Overall Dimensions: 3.00 x 2.10 x .92 inches 76.20mm x 53.34mm x 23.37mm Weight: 0.25 LBS113 kg MAX. ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING A. Units should be allowed to warm up/operate under non-condensing Temperature (A) 0 to 50 C -40 to +85C conditions before application of power. Humidity (A) 0 to 95% RH 0 to 95% RH B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 Shock (B) 20 g 40 g orthogonal axes, total 6 shocks. pk pk Altitude -500 to 10,000 ft -500 to 40,000 ft C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms rms hr./axis non-operating. SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 1/07. Data Sheet 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.