GSC25 Commercial/GSM25 Medical
25 Wtat Goblal Performance S Witcher S
GLOBAL PERFORMANCE SWITCHERS
Features:
D C P o w e r S u p p l i e s
Industrys smallest 25 W switcher
2.50 x 4.25 x 0.86
Conducted EMI exceeds FCC Class B and
CISPR 22 Class B (Commercial models) and
CISPR 11 Class B (Medical models)
Overvoltage protection standard
Commercial Approved to UL1950,
CSA-C22.2 No.950, EN60950
Medical Approved to UL2601-1, IEC60601-1
EN60601-1 and CSA-C22.2 No. 601-1
RoHS Compliant (G suffix)
marked to LVD
SPECIFICATIONS
Ac Input Inrush Current
90-264 Vac, 47-63 Hz single phase.
Inrush is limited by internal thermistor. The inrush at 230 Vac, averaged over the
first ac half-cycle under cold start conditions will not exceed 32 A.
Input Current
Maximum input current at minimum 120 Vac, 60 Hz with full rated output Temperature Coefficient
load is 0.6 A.
0.03%/C typical on all outputs.
Hold-up Time
Environmental
15 ms minimum from loss of ac input at full load, nominal line (120 Vac). Designed for 0 to 50C operation at full rated output power; derate output current
and total output power by 2.5% per C between 50 - 70C. See Environmental and
Output Power
Packaging Specifications on next page.
Normal continuous output power is 25 W, 28 W peak for 60 sec. maximum
duration, 10% duty cycle. Factory set to begin power limiting at approxi-
EMI/EMC Compliance
mately 30 W. All models include built-in EMI filtering to meet the following emissions require -
ments:
Output Regulation
Regulation from initial setpoint measured by changing load from 5% load to
EMI SPECIFICATIONS COMPLIANCE LEVEL
50% load or 50% load to full load in either direction. Initial setpoint tolerance
Conducted Emissions GSC25 EN55022 Class B; FCC Class B
is measured at 50% load. A minimum load of 5% of the output current on the
Conducted Emissions GSM25 EN55011 Class B; FCC Class B
+5.1 V output (125 mA) is required to maintain proper regulation.
Static Discharge EN61000-4-2, 6 kV contact, 8 kV air
RF Field Susceptibility EN61000-4-3, 3 V/meter
Overload Protection
Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz
Fully protected against short circuit and output overload. Short circuit protec-
Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
tion is cycling type power limit
Commercial Safety:
Output Noise
Condor D.C. Power Supplies, Inc. declares under our sole responsibility that all GSC
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with
models are in conformity with the applicable requirements of EN60950 following
scope probe directly across output terminals of the power supply with load
the provisions of the Low Voltage Directive 73/23/EEC. All GSC models are ap-
terminated with 0.1 uF capacitor.
proved to UL1950, CSA-C22.2 No.950, EN60950.
Transient Response
GSM25 Medical Model Earth Leakage Current
Main output: 750 s typical response time for return to within 0.5% of final
Leakage current measured in the Gnd wire connection when measured per
value for a 50% load step within the regulation limits of minimum and maxi-
UL2601-1 or IEC60601-1 is as follows:
mum load, l/t <0.2 A/s. Maximum voltage deviation is 3.5%. Startup/shut -
down overshoot less than 2%.
Model Normal Fault Test Test
Leakage Leakage Voltage Method
Overvoltage Protection
GSM25 50 A 78 A 132 Vca/60 Hz UL2601-1
Built in with firing point set per ratings table. OVP firing reduces voltage to
less than 50% of nominal voltage in 50 ms.
GSM25 94 A 150 A 264 Vca/50 Hz IEC60601-1
Voltage Adjustment
Medical Safety
Factory set with fixed resistors to maximize reliability.
Condor D.C. Power Supplies, Inc. declares under our sole responsibility that all
GSM models are in conformity with the applicable requirements of UL2601-1
Efficiency
Patient Care Equipment, CSA-C22.2 No.601.1, IEC60601-1, EN 60601-1.
70% minimum at full rated load, nominal input voltage.
Input Protection
Internal ac fuse provided on all units.
O
All specifications are typical at nominal input, full load at 25 C unless otherwise statedLoad
Commercial Medical Initial Setpoint OVP Ripple and
Model Model Output No. Output Current Regulation Tolerance Setting Noise Notes
GSC25A GSM25A 1 + 5.1 V 2.5 A 1% 1% 6.2 0.6 V 1% A
2 +12 V 1.5 A 4% 3% 1% A
3 - 12 V 0.2 A 1% 4% 1% B
GSC25B GSM25B 1 + 5 V 2.5 A 1% 1% 6.2 0.6 V 1% A
2 +15 V 1.5 A 4% 3% 1% A
3 - 15 V 0.2 A 1% 4% 1% B
GSC25D GSM25D 1 +5.1 V 2.5 A 1% 1% 6.2 0.6 V 1% A
2 +24 V 1.0 A 4% 3% 1% A
3 -12 V 0.2 A 1% 4% 1% B
A. To maintain proper regulation on output 2, +5.1 V current must be at least 14 and not greater than 5 times V2 current. V1 must be adjusted within 1% of 5.1 V
to maintain full load regulation on V2.
B. Thermal foldback type current limit
C. Add G suffix to model number for RoHS compliant model.
GSC25/GSM25 MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING
Temperature (A) See individual specs. -40 to +85C
A. Units should be allowed to warm up/operate under
Humidity (A) 0 to 95% RH 0 to 95% RH
non-condensing conditions before application of power.
Shock (B) 20 g 40 g
pk pk B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction,
3 orthogonal axes, total 6 shocks.
Altitude -500 to 10,000 ft -500 to 40,000 ft
C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350
2 2
Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
rms rms
1 hr./axis non-operating.