MINT1045
45 W Single Output Series
Medical & ITE Universal Input Power Supply 3 Year Warranty
45 W Convection Cooled
Universal Input 80--270 Vac
Very Small Size: 2 W x 3 L x 1.0 H
88% Efficiency Typical
Class I or Class II AC Input Applications
rd
CSA/EN/IEC/UL60601-1 3 Edition for Medical,
Type BF Capable, Ultra-low Leakage Current
nd
CSA/EN/IEC/UL60950-1 2 Edition for ITE
Specifications All Specifications are typical at nominal input, full load at 25C unless otherwise stated.
AC Input 100-240Vac +/- 10%, 47-63 Hz 1 rated T u r n On Time 500 ms max at 120 Vac
80-270 Vac, 47-440 Hz operational
Input Current 0.75A @ 120 Vac, 0.45 A @ 240 Vac Hold-up Time 25 ms minimum at 45 W, nominal input (120Vac)
Inrush Current 37A max., 264 Vac Overvoltage Protection 120-150%, auto-reset
Input Fuses F1, F2: 1.6A, 250Vac fuses provided internally Overload Protection Hiccup Mode, 58W typical
Power Factor Complies with EN61000-3-2, Class A Short Circuit Protection Hiccup Mode, 58W typical
Efficiency 88% typical Overtemperature Protection Self-Recovering
rd
Output Power 45 W continuous. See chart for operation above 50C Medical Safety Standards CSA/EN/IEC/UL 60601-1, 3 Edition
Methods Of Protection: 2 MOPP for Type BF Applications
nd
Peak Output Power 50 W for 1 minute, 10% duty cycle ITE Safety Standards CSA/EN/IEC/UL 60950-1, IEC 2 Edition
See page 2 for detailed safety agency standards
Ripple and Noise 1% pk-pk max., 20 MHz BW, differential mode Isolation Input-Output: 4500Vac, Input-Ground: 1900Vac
Measured with noise probe directly across output terminals Output-Ground: 1900Vac
Output Voltage See chart Leakage Current 12V-28V models: 120Vac: 30A NC/70A SFC
264Vac: 75A NC/130A SFC
48V model: 120Vac: 90A NC/120A SFC
264Vac: 190A NC/220A SFC
Voltage Adjustability Not adjustable Operating Temperature -20 to 70C
Factory set with fixed resistors for higher reliability
See derating chart
Minimum Load Not required Output Power Derating Derate output power by 2.5%
per C above 50C, up to 70C max
Total Regulation See chart Storage Temperature -40 to +85C
Transient Response 500s max. to 1%, 50% load step Relative Humidity 5% to 95%, non-condensing
0.2A/s, 3.5% deviation. typical
Switching Frequency Fixed 65 kHz, typical MTBF 300K hours per Telcordia
Model Number Key
MINT 1 045 A 12 75 K 01
01 = Standard Model, 02 and higher indicates a modified model. = Input Connector - 3 pin header
75" = Output Connector - 4 pin header
Output Voltage:12" = 12V output,24" = 24V output, etc.
Model Configuration: = Class I Input; = Class II Input (no ground)
Output Power (Watts) -045" = 45W
# of Outputs
Product Family: = Medical, = Internal,N = New Technology
______________________________________________________________________________________________________________________________ 1 of 3
SL Power Electronics Corp 6050 King Drive Ventura, CA 93003 Phone 805.486.4565 Fax 858.712.2040 Email: info@slpower.com www.slpower.com
MINT1045
45 W Single Output Series
Medical & ITE Universal Input Power Supply 3 Year Warranty
Output Parameters
Model Output Ripple Total Initial Set-point
Number Volts Current & Noise Regulation Tolerance
MINT1045A1275K01 12 V 3.75 120mV 0.5% 2%
MINT1045A1575K01 15 V 3.00 150mV 0.5% 2%
MINT1045A2475K01 24 V 1.90 240mV 0.5% 2%
Consult factory for availability
MINT1045A2875K01 28 V 1.60 280mV 0.5% 2%
MINT1045A4875K01
48 V 0.95 480mV 0.5% 2%
Notes:
1. Derate output power by 2% per volt AC for input voltage <90Vac.
Specifications (continued)
Vibration Random vibration per MIL-STD-810E, Method 514.4, Shock Half-sine, 40 gpk, 10 msec duration, +/- in
Cat. 1, Figure 514.4-1, 1 hr in each of three axes each of three axes, total of 6 shocks
Enclosure Dimensions See outline drawing Operating Altitude -500 to 10,000 ft
Weight 113 grams Non-operating Altitude -500 to 40,000 ft
EMI/EMC Compliance
Conducted Emissions EN55011/22 Class B, FCC Part 15, Class B, 6db margin
Radiated Emissions EN55011/22 Class A, FCC Part 15, Class A, 10db margin
To meet class B for grounded input (Class I), unit should be
mounted on a metal plate.
Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
Radiated RF Immunity EN61000-4-3, 3V/m.
EFT/Burst Immunity EN61000-4-4, 2kV/5kHz.
Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode
Conducted RF Immunity EN61000-4-6, 3Vrms
Power Frequency Magnetic Field Immunity Convection Cooled
EN61000-4-8, 3A/m
Voltage Dip Immunity EN61000-4-11 100Vac, 95% dip/0.5 cycle (Criteria A),
60%/5cycles (Criteria A at 30% load), 30%/25 cycles (Criteria A).
Line Frequency Harmonics Complies with EN61000-3-2, EN60601-2-1
Safety Agency Compliance
Medical Certification to the New 3rd Edition: ITE Certification to the New 2nd Edition:
Demko certified to EN 60601-1:2005, 3rd Ed. Demko certified to EN60950-1:2006+ A11:2009,2nd Ed.
CB certified to IEC 60601-1:2005, 3rd Edition CB certified to IEC 60950-1:2005, 2nd Edition
UL Recognized to ANSI AAMI ES60601-1:2005 UL Recognized to UL 60950-1:2007, 2nd Edition &
& CAN/CSA C22.2, No. 60601-1-08 CAN/CSA C22.2, No. 60950-1-07, 2nd Edition
______________________________________________________________________________________________________________________________ 2 of 3
SL Power Electronics Corp 6050 King Drive Ventura, CA 93003 Phone 805.486.4565 Fax 858.712.2040 Email: info@slpower.com www.slpower.com