180W Single Output MINT1180 Family Medical Grade FEATURES AND BENEFITS Medical 3 x 5 x 1.3 Package 180W Convection Cooled Power Ideal for 1U Applications Class I and Class II versions Approved to CSA/EN/IEC/UL60601-1, 3rd Edition, 2 x Universal Input 90-264 VAC MOPP Isolation Approved to EN/CSA/IEC/UL62368-1 Efficiency 90% typical 3 Year Warranty RoHS Compliant MODEL SELECTION Ripple & Total Model Number Volts Output Current* Minimum Load OVP Threshold Noise** Regulation MINT1180A1275K01 12V 15.0A 0A 120mV pk-pk 3% 14.0 1.1V MINT1180A1575K01 15V 12.0A 0A 150mV pk-pk 3% 18.5 1.2V MINT1180A1875K01 18V 10.0A 0A 180mV pk-pk 3% 21.5 2.0V MINT1180A2475K01 24V 7.50A 0A 240mV pk-pk 3% 29.0 2.5V MINT1180A2875K01 28V 6.40A 0A 280mV pk-pk 3% 33.5 2.5V MINT1180A3275K01 32V 5.62A 0A 320mV pk-pk 3% 36.0 3.0V MINT1180A4875K01 48V 3.75A 0A 480mV pk-pk 3% 56.0 3.0V Notes: 1. * Total convection power is 180 Watts. 2. ** Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors. INPUT OUTPUT 100-240Vac, 10%, 47-63Hz, 1 Output Voltage See models chart AC Input 120370Vdc Output Power 180W convection cooled Input Current 115Vac: 1.8A, 230Vac: 0.9A Turn On Time Less than 3 sec. 115Vac & Full Load Inrush Current 264Vac, cold start: will not exceed 55A Hold-up Time >16mS at 180W, 120Vac F1, F2: 4.00A, 250VAC fuses provided on all Input Fuses Ripple and Noise See models chart models Total Regulation +/- 3% combined line, load and initial setting. Earth Leakage Current <275A 264Vac, 60Hz, NC <400A SFC PFC: Fixed, 65kHz, Main Converter: Variable 35- Efficiency 88% typical Switching Frequency 200kHz, 65-70kHz at full load. Minimum Load Not required 500S typ. for return to within 0.5% of nominal, 50% Transient Response load step. Di/Dt <0.2A/S. Max Volt Deviation = 3% Voltage Adjustability Fixed output Page 1 MINT1500 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.180W Single Output MINT1180 Family Medical Grade PROTECTION EMI/EMC COMPLIANCE OVP latch at 110%-130% of rated output EN55011/22 Class B, FCC Part 15, Subpart B, Overvoltage Protection Conducted Emissions voltage. Class B EN55011/22 FCC Part 15, Class A with 6dB Provided - no damage will occur if the output Radiated Emissions Margin is Short Circuit Protection shorted, auto recovery EN61000-4-2, Criteria A, 6kV Contact Static Discharge Immunity Discharge, 8kV air discharge Provided, self-recovering Automatic power Overtemperature Pr otection shutdown at TC 135C/115C Radiated RF Immunity EN61000-4-3, 3V/m. Criteria A 120% to 140% of current rating, Hiccup Mode Overload Protection EFT/Burst Immunity EN61000-4-4, 2kV/5kHz, Criteria A EN61000-4-5, 1kV differential, 2kV common- Line Surge Immunity mode, Criteria A ENVIRONMENT Conducted RF Immunity EN61000-4-6, 3Vrms, Criteria A Power Frequency Magnetic -10C to +70C, Start Up at -40C, full load Operating Temperature EN61000-4-8, 3A/m, Criteria A Field Immunity 5% to 95%, non-condensing Relative Humidity EN61000-4-11, 5% Vnom: 0.5cycle 40% Vnom: Voltage Dip Immunity 5 cycles, 70% Vnom: 25 cycles, Criteria A 325g Weight Line Harmonic Emissions EN61000-3-2, Class A, B, C, & D W: 3.0 x L: 5.0 x H: 1.3 Dimensions Flicker Test EN61000-3-3, Complies (dmax<6%) Operating: -500 to 10,000 ft. Altitude Non-operating: -500 to 40,000 ft. -40C to +85C Storage Temperature RELIABILITY Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, Non-Operating: 0.026g/Hz, 5.0grms Vibration 214,194 hours, 25C, 110Vac MTBF overall, 3 axes, 1 hr/axis Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total, Non-Operating: Half-sine, 40 gpk, 10 ms, 3 Shock SAFETY axes, 6 shocks total EN/CSA/UL/IEC 60601-1, 3rd Edition Safety Standards Approved to EN/CSA/IEC/UL62368-1 ISOLATION Input-Output: 4000Vac, 2 x MOPP Isolation Input-Ground: 1800Vac, 1 x MOPP Output-Ground: 1500Vac Page 2 MINT1500 Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.