110W Triple Output MINT3110 Family Medical Grade FEATURES AND BENEFITS Medical 2 x 4 x 1.3 Package )2 7% 90 -) VH )HMXMSR Suitable for 1U Applications 2 x MOPP Isolation Class I and Class II Versions Power Fail Signal 110W w/air, 80W Convection Cooled Remote Sense (optional) Universal Input 90-264Vac 3 Year Warranty Efficiency 87% Typical RoHS Compliant MODEL SELECTION Output Current*** Ripple & Model Number Volts* Total Regulation OVP Threshold *** w/200LFM air Convection Noise V1 5V 14.0A 10.0A 1.0% pk-pk 2% 7.5V max. MINT3110A0508K01 V2 12V 6.0A 4.5A 1.0% pk-pk 3% 115%-135% V3 -12V 1.0A 1.0A 2.0% pk-pk 10% 115%-135% V1 5V 14.0A 10.0A 1.0% pk-pk 2% 7.5V max. MINT3110A1708K01 V2 15V 4.5A 3.5A 1.0% pk-pk 3% 115%-135% V3 -15V 1.0A 1.0A 2.0% pk-pk 10% 115%-135% V1 5V 12.0A 8.0A 1.0% pk-pk 2% 7.5V max. MINT3110A1908K01 V2 24V 4.0A 3.0A 1.0% pk-pk 3% 115%-135% V3 -24V 1.0A 1.0A 2.0% pk-pk 10% 115%-135% Notes: 1. * 5V output is adjustable with +/-5% range 2. ** Total convection power is 80 Watts 3. *** Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors. Ripple & Noise of V2 at no 4. load is 2% maximum Page 1 MINT1500 Datasheet v1220 Copyright 20 20 SL Power Electronics Corp. All rights reserved.110W Triple Output MINT3110 Family Medical Grade INPUT OUTPUT AC Input 100-240Vac, 10%, 47-63Hz, 1 120370Vdc Output Voltage See models chart 110W continuous with 200 lfm airflow, 80W 115Vac: 1.5A, 230Vac: 0.75A Input Current convection cooled See chart for specific Output Power Inrush Current 264Vac, cold start: will not exceed 45A voltage model ratings F1, F2: 2.5A, 250Vac fuses provided on all models Input Fuses Less than 2 sec. 115Vac (inversely proportional to Turn On Time input voltage and thermistor temperature) Earth Leakage Current <290A 264Vac, 60Hz, NC Hold-up Time 16mS typical at 110W, 120Vac input 87% typical at 230Vac Efficiency See models chart Ripple and Noise Total Regulation See models chart PFC: Variable 30-400kHz. Main Converter: Variable Switching Frequency EMI/EMC COMPLIANCE 35-180kHz, 65-70kHz at full load Minimum Load Not required EN55011/22 Class B, FCC Part 15, Subpart B, Conducted Emissions Class B EN55011/22 Class A FCC Part 15, Subpart A, Radiated Emissions ENVIRONMENT Class A EN61000-4-2, Criteria A, 8kV Contact Discharge, Static Discharge Immunity Operating Temperature -10C to +70C 8kV air discharge Relative Humidity 5% to 95%, non-condensing Radiated RF Immunity EN61000-4-3, 3V/m, Criteria A Weight 200g EFT/Burst Immunity EN61000-4-4, 2kV/5kHz, Criteria A Dimensions W: 2.0 x L: 4.0 x H: 1.3 EN61000-4-5, 1kV differential, 2kV Line Surge Immunity common-mode, Criteria A Derate output power linearly above 50C to 50% at Temperature Derating 70C Conducted RF Immunity EN61000-4-6, 3Vms, Criteria A Operating: -500 to 10,000 ft. Non-operating: -500 to Power Frequency Magnetic Altitude EN61000-4-8, 3A/m, Criteria A 40,000 ft Field Immunity Storage Temperature -40C to +85C EN61000-4-11, 0% Vin, 0.5cycle 40% Vin, 5cycle Voltage Dip Immunity 70% Vin, 25 cycles Criteria A Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 Vibration min/axis Non-Operating: 0.026g/Hz, 5.0grms overall, Line Harmonic Emissions EN61000-3-2, Class A,B,C, & D 3 axes, 1 hr/axis Flicker Test EN61000-3-3, Complies (dmax<6%) Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks Shock total Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total PROTECTION See models chart for trip range Overvoltage Protection ISOLATION Provided - no damage will occur if the output is Short Circuit Protection shorted Input-Output: 4000Vac, 2 x MOPP Isolation Input-Ground: 1800Vac, 1 x MOPP 150%-300% above rating for V2 & V3, 110% Overload Protection Output-Ground: 500Vac 200% for V1, Hiccup Mode RELIABILITY SAFETY MTBF 245,000 hours, 25C Ambient, 110Vac input Safety Standards EN/CSA/IEC/UL62368-1 Page 2 MINT1500 Datasheet v1220 Copyright 20 20 SL Power Electronics Corp. All rights reserved.