Uninterruptible Power Systems 2 S1K Mini-Tower Off-line UPS The S1K series provides economical protection from damaging impulses and power interruptions. These units include two types of outlets three for critical devices needing battery back-up and surge protection such as the CPU and one surge protected only outlet for non-critical devices like printers and fax machines. The S1K is ideal for point of sale and office applications. Applications PCs Workstations E179213 Computer Terminals Certifications and Compliances Features Listed, UPS Equipment Lightweight, compact design - UL 1778, CSA C22.2 No. 107.3 4 NEMA 5-15R outlets, (3 Battery, 1 Surge) Data-line surge protection for phone or network included on every unit. Related Products DB9 communications Interface Surge Protective Devices Software and cable included Active Tracking Filters Step sinewave output Portable MCR Power Conditioners Two year limited warranty Selection Table Capacity Catalog Volts, Frequency Typical Back-up Time * Input Plug/ Approx. Ship Weight (VA/W) Number In/Out (minutes) Output Receptacle lbs (kg) 320/240 10 8.8 (4.00) S1K320 520/340 15 11.6 (5.30) S1K520 5-15P / 5-15R 650/390 15 8.1 (3.70) S1K650 (3) Battery (1) Surge 115 Vac, 50 or 60 Hz 850/600 25 10.8 (4.90) S1K850 1200/720 30 10.8 (4.90) S1K1200 1500/900 70 5-15P / 5-15R (4) Battery 30.0 (13.60) S1K1500 * For a typical PC with a 15 monitor. S1K Accessories Catalog Number Description Approx. Ship Weight lbs (kg) Wall/panel mount bracket kit for S1K (320VA~1200VA) UPS 1.0 (0.45) S1K-PMBRK ** RS232 to USB Adapter Cable 1.0 (0.45) UPSMON-USB ** Not applicable to S1K1500 and S1K650 Contact Technical Services at (800) 377-4384 with any questions. 66 Visit our website at www.solahd.com. Uninterruptible Power Systems 2 Specifications Catalog Number S1K320 S1K520 S1K650 S1K850 S1K1200 S1K1500 320/240 520/340 650/390 850/600 1200/720 1440/900 Capacity (VA/Watts) Dimensions - inches (mm) 5.30 x 3.80 x 12.60 5.30 x 3.80 x 12.60 7.50 x 5.11 x 15.00 5.30 x 3.80 x 12.6 5.30 x 3.80 x 10.40 Unit (H x W x D) - (135.0 x 97.0 x (135.0 x 97.0 x (191.0 x 130.0 x in. (mm) (135.0 x 97.0 x 320.0) (135.0 x 97.0 x 264.0) 320.0) 320.0) 381.0) 8.8 (4.00) 11.6 (5.30) 8.1 (3.70) 10.8 (4.90) 30.0 (13.60) Weight - lbs (kg) Input Parameters 115V + 20% / -25% 115V +/-15% 115V +/-25% Voltage 50 or 60 Hz 10% (auto sensing) Frequency 6 ft. with NEMA 5-15P Input Power Cord Output AC Parameters Step sinewave at 115V Voltage (Battery Mode) 10% 5% 50 or 60 Hz Frequency (On Battery) 1 Hz 0.3 Hz 1 Hz AVR automatically increases output Auto Voltage voltage 15% above input voltage if 91% AVR Regulation to 75% of nominal. AVR decrease output N/A (See first column (AVR function voltage 13% below input voltage if 109% to for definition) under Normal 125% of nominal Mode) UPS automatic shutdown if over- UPS automatic shutdown if overload exceeds 105% of nominal at 20 seconds, load exceeds 110% Overload 120% at 10 seconds, 130% at 3 seconds of nominal at Protection 60 seconds, 130% at 3 seconds UPS output cut off immediately Short Circuit Battery Parameters Sealed, maintenance-free lead acid batteries Battery Type 4 milliseconds, Typical Transfer Time Back-up Time * 10-20 15-25 15-30 25-40 30-45 70-80 (minutes) 4 hours 6 hours Recharge Time Environmental Operating 0C to 40C Temperature Storage -15C to 50C Temperature 0% to 90%, non-condensing Relative Humidity 0-95% humidity non-condensing, 0-40C up to 10,000 ft. (3000m) Ambient Operation < 40dBA (1 meter from surface) Audible Noise Standards FCC Part 15, Subpart B, Class A EMC Meets IEEE C62.41, Category A Surge Protection * For a typical PC with a 15 monitor. Contact Technical Services at (800) 377-4384 with any questions. 67 Visit our website at www.solahd.com.