Power Supplies SDN-C Performance DIN Rail Series High performance specifications and extensive international UL 60950 E61379 E137632 certifications ensure that the SolaHD SDN-C is suitable UL 508 Listed E137632 CUL/CSA-C22.2E234790 IND. CONT. EQ. for the most extreme environments, including hazardous No. 234-M90 E61379 locations and off-shore applications. Features like wide EMC and operating temperature range, power boost capability, Low Volt. IECEx and adjustable output voltage ensure reliable operation in Directive the harshest industrial environments. Parallel operation, extensive LED diagnostics, and universal AC or DC input voltage simplify installation and maintenance. For added reliability, the SDN-C power supplies can be used with the SolaHD Redundancy modules to provide redundant power Certifications and Compliances * supply operation. All Models Applications Listed, Ind. Control Equipment, E61379 Industrial Automation UL 508 Listed - UL 508, CSA C22.2 No. 107.1 IND. CONT. EQ. Process Control E61379 UL Recognized Component, ITE, E137632 UL 60950 Material Handling and Conveyors E137632 - UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition CUL/CSA-C22.2 No. 234-M90 Hazardous Locations UL Recognized Component, Class I, Div 2 UL 60950 Marine Applications Class I Zone 2 T4 E234790E137632 CUL/CSA-C22.2 No. 234-M90 - Low Voltage Directive Features EMC and - IEC/EN60950-1, 2nd Edition Low Volt. Extensive international hazardous location certifications, Directive RoHS Compliant including Class I, Zone 2, ATEX, IECEx, ExEAC. Hazardous location temperature code (T-Code) rating Models SDN 5-24-100C, SDN 10-24-100C, SDN 16-12-100C, SDN of T4. 20-24-100C, SDN 40-24-100C, SDN 5-24-480C, SDN 10-24-480C, International off-shore certifications, including ABS and SDN 20-24-480CD DNV-GL UL Recognized Component, Haz. Loc., E234790 TM UL 60950 PowerBoost enables short duration overload E137632 - UL60079-0/CSA E60079-0, UL 60079-15, CSA CUL/CSA-C22.2 capability, to start loads with high inrush current No. 234-M90 E60079-15 Three LEDs provide extensive diagnostics - Class I, Zone 2, AEx nA nC IIC, Ex nA nC IIC Dual output terminals for convenience in wiring ATEX Directive DC OK relay to provide diagnostic information to a PLC, - EN60079-0, EN60079-7, EN60079-15 controller, or monitoring system Universal AC and DC input voltages to accommodate - II 3 G, Ex ec nC IIC Gc global requirements IECEx Certified Wide operating temperature range accommodates both - IEC 60079-0, IEC 60079-7, IEC 60079-15 extreme hot and extreme cold environments - Ex ec nC IIC Gc Active Power Factor Correction on most models Models SDN 5-24-100C, SDN 10-24-100C, SDN 16-12-100C, SDN Parallel operation capability standard 20-24-100C, SDN 40-24-100C, SDN 5-24-480C, SDN 10-24-480C Supports redundant power supply operation using optional SDN Redundancy modules TR CU 012/2011 Safety of Equipment intended for 5-year limited warranty Explosive Atmospheres Type Approval Models SDN 5-24-100C, SDN 10-24-100C, SDN 16-12-100C, SDN 20-24-100C, SDN 40-24-100C Type Approved Models SDN 5-24-100C, SDN 10-24-100C, SDN 20-24-100C, SDN 40-24-100C Certified * Refer to user manual for installation requirements when used in hazardous locations. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 122 December 2018Power Supplies Related Products Accessories SDN-C Redundancy Modules Chassis Mount Brackets IP67 SCP-X Extreme Environment Series SDU UPS The SolaHD Difference Multiple output connections for ease of Rugged metal housing wiring multiple devices Visual LED diagnostics show input and output status (see table below) DC OK Relay Terminals provide diagnostic information to a PLC or controller Single or parallel use selectable by user Adjustable output voltage Clearly labeled front panel No internal fan, no extra cooling required in any power level Multiple certifications for versatility in applications Automatically adjusts for global Input voltages Narrow width saves panel space LED Light Status Conditions Normal AC Power Loss AC Input Low No DC High Load Overload Hot Too Hot Green - Amber Green Green Green Green Green Input Green - Green - Amber Amber Green - Output - - - Red Amber Red Amber Amber Alarm Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 123 December 2018