Wall mount SYS1381-Wxx series 6W~12W Country of Origin : China Operating Temperature : 0~40 C Dimension : 63.6 x 29.5 x 45.6 mm Efficiency level (ErP) : Approvals / Marks : Features: Available in version: W2E(EU), W2(USA/Japan/Canada/Taiwan), W3U(UK), W2A (Australia), W2C (China), W2K(Korea). Wall-mount power supply, single output. Overload, over voltage & short protection. Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz. For I.T.E. use only + RoHS conform. Specification: Voltage Total Hold up Max. Ripple & Loading OCP OVP Efficiency Connector Model DC regul. time Power Noise A A V % mm V % ms W mV p-p SYS1381-1005-Wxx 5 0~2.0 5 2.4~5.0 104 8 >73.4 10 80 1.7x4.0x11 SYS1381-1005-Wxx 5 0~2.0 5 2.4~5.0 104 8 >73.4 10 80 2.1x5.5x11 SYS1381-1005-Wxx 5 0~2.0 5 2.4~5.0 104 8 >73.4 10 80 2.5x5.5x11 ErP V. SYS1381-0606-Wxx 6 0~1.0 5 1.3~3.5 103 10 >70.0 6 120 2.1x5.5x11 SYS1381-0808-Wxx 7,5 0~1.07 5 1.3~3.5 167 8 >72.0 8 130 2.1x5.5x11 SYS1381-0909-Wxx 9 0~1.0 5 1.5~3.5 154 8 >73.0 9 130 2.1x5.5x11 SYS1381-1212-Wxx 12 0~1.0 5 1.2~3.5 184 8 >77.8 12 180 2.1x5.5x11 SYS1381-1224-Wxx 24 0~0.5 5 0.7~1.5 404 8 >77.8 12 240 2.1x5.5x11 ErP V. / CE only SYS1381-1215-Wxx 15 0~0.8 5 1.0~3.0 214 8 >77.8 12 240 2.1x5.5x11 Wxx Possible to order with Wxx = W2E - Europe W2 - USA,Canada,Japan W3U - UK W2A - Australia W2C - China W2K -Korea This model is certified for Output: Uout V /Pout W max : (5/10, 6/6, 7.5/8, 9/9,12/12). Pout=by 1W steps OEM Production Turn on delay 5000 ms max OUTPUT Hold up time Ref. upon table AC nominal input output full load (1 half cycle) Efficiency (Normal) >70% 240VAC input & Full load Voltage (90 ~ 264)VAC Frequency (47 ~ 63) Hz Current 0.5A rms any input voltage and rated DC output rated load INPUT Inrush Current (cold start) 40/60Amax. 264VAC input. Cold start at 240VAC input, with rated load and 25 ambient Leakage current 0.25 mA Max. Power consumption 0.3W rms max. At AC nominal input output min load Over Current The power supply will be auto recovered when over current faults remove. >>Fold back<< Over Voltage The power supply will not be auto recovered when faults remove >>Voltage limit<< PROTECTION The power supply will be auto recovered when short circuit faults remove. An output short circuit is defined as any output imped- Short Circuit ance of less than 0.1 . Protection class II. Dielectric Strength(Hi-pot) Primary to Secondary: 3000VAC / 10mA / 60s M.T.B.F 50K hours full rated load operation at 25C, according to the MIL-HDBK-217F. Cable length 2wires. / 2468 22*2C 1370mm (4.5feet) or customer requirements OTHERS Input protection 1A Fuse, The power supply shall be protected against power line surges and any abnormal condition. Temperature coefficient: < 0.5% / C Temperature Operating: (0 ~ 40)C / Storage: (-20 ~ 85)C ENVIRONMENT Humidity Operating:8% ~ 90% RH / Storage: 5% ~ 95% RH non condensing SAFETY CE TUV/GS CB FCC cULus BSMI VCCI PSE T-License SAA C-Tick CCC KC S Mark RCM EN 55022 Class B (2006)+ A1(2007) EMI EN 61000-3-2 (2006) + A1(2009) + A2 Class A(2009)/EN 61000-3-3 (2008) EMC EN55024(1998)+A1(2001)+A2(2003) IEC 61000-4-2 (2008) IEC 61000-4-3 (2006) + A1(2007) + A2(2010) EMS IEC 61000-4-4 (2004) + A1(2010) IEC 61000-4-5 (2005) IEC 61000-4-6 (2008) IEC 61000-4-8 (2009) IEC 61000-4-11 (2004) WEIGHT 1pc N.W.: 90g/pc G.W.: 100g/pc 0.48(L) x 0.44(W) x 0.26(H) m 0.435(L) x 0.370(W) x 0.175(H) m Box 80pcs / 1box (100pcs 2011/2012) PACKING G.W.: 10 kg/box www.sunny-euro.com Wall mount SYS1381-Wxx series 6W~12W Mechanical case specification: Mechanical specification (country housing): Europe / Korea type (W2E/W2K) US / Canada type (W2) Australia type (W2A) UK type (W3U) Cable specification: a) 2.1*5.5*11 (2468 22*2C / 5FT) www.sunny-euro.com