SYS1421 series Wall-mount 2.5W~6W Country of Origin : China Operating Temperature : 0~ 40 C Dimension : 64 x 48.5 x 25.5 mm Efficiency level (E.L.) : V. Approvals / Marks : Features: PSU housing ready for use in country : Overload, over voltage & short protection. For I.T.E. use only + RoHS conform. USA/Japan/Taiwan/Cana Europe (type W2E) da (type W2) Wall-mount power supply, single output. Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz. Australia (type W2A) Korea (type W2K) UK (type W3U) China (type W2C) Specification: OUTPUT Voltage min. max. Effici- Max. Ripple Tol. OCP OVP Connector mm Model DC Load Load ency Power & Noise % A V UL approval V A A % W mV p-p yy =05 or 12 xx=01~06 SYS1421-xxyy 0 1.2 (*) (*) (*) (*) (*) (*) ErP V. 1.5~3.5 SYS1421-0605-W2E 5 0 1.2 5 124 >69.53 6 150 2.1x5.5x11 ErP V. 1.3~3 >68.1 SYS1421-0605-W2E 5 0 1 5 124 5 150 mini USB ErP V. 1.3~3 SYS1421-0605-W2E 5 0 0.8 5 124 >66.49 4 150 micro USB ErP V. 0.75~2 >62.97 SYS1421-0605-W2E 5 0 0.5 5 124 3 150 USB inlet ErP V. 0.6~2 SYS1421-0612-W2E 12 0 0.5 5 174 >73.41 6 150 2.1x5.5x11 (*) will be provide with the specify model Turn on delay 5000 ms max AC low line input output full load Hold up time 8ms min AC nominal input output full load (> half cycle) Efficiency (Normal) In the table above minimum average efficiency in active mode(Meet CEV V) Transient response (dv, tmax) 0.4V dv max AC nominal input loading from 20% load to 80% load OUTPUT 6ms tmax Dynamic rise time 10uS max, duty 40mS max, Dynamic load step is slew rate of 0.5A/uS Power out. Limit Peak 7W for model- 0605 Burn in test Full load 2 Hours before testing Voltage (90 ~ 264)VAC Frequency (47 ~ 63) Hz Current 0.5A rms AC low line input and DC output full load Inrush Surge Current INPUT 30/60A max power supply cold start, ambient temperature 25 115Vac / 230Vac nominal AC input. (cold start) Leakage current 0.25 mA Max. Power consumption 0.3W rms max. At AC nominal input output min load 0.5W rms max model 2415 Over Current /Short protection The power supply will self-protect any output to ground, and auto recovery when abnormal circuit faults remove. An output short circuit is defined as any output impedance of less than 0.1 ohms. OCP Over Voltage The power supply will not be auto recovered when faults remove >>Voltage limit<< OVP PROTECTION Input protection 1A Fuse or 10R2W The power supply shall be protected against power line surges and any abnormal condition. No load protection The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class II. Dielectric Strength (Hi-pot) Primary to Secondary: 3000VAC / 10mA / 60s M.T.B.F 50K hours full rated load operation at 25 , according to the MIL-HDBK-217F. Cable length / type 1836mm (6feet) round cable or depends on customer requirements / 2468 24, 5FT PLD (power line disturbance ) LINE POWER SURGE LINE VOLTAGE SAG more information will be provide on request OTHERS Cooling method By natural air Housing matherial PC or PPO Temperature coefficient: < 0.5% / C Temperature Operating: (0 ~ 40)C / Storage: (-20 ~ 85)C ENVIRONMENT Humidity Operating: 8% ~ 90% RH / Storage: 5% ~ 95% RH non condensing CE TUV/GS CB UL cUL FCC BSMI PSE VCCI C-TICK SAA T-licence SAFETY EN 55022 Class B (2006)+ A1(2007) EMI EN 61000-3-2 (2006) + A1(2009) + A2 Class A(2009)/EN 61000-3-3 (2008) EMC EN55024(1998)+A1(2001)+A2(2003) IEC 61000-4-2 (2008) IEC 61000-4-3 (2006) + A1(2007) + A2(2010) EMS IEC 61000-4-4 (2004) + A1(2010) IEC 61000-4-5 (2005) IEC 61000-4-6 (2008) IEC 61000-4-8 (2009) IEC 61000-4-11 (2004) 1pc N.W.: 50g / pc WEIGHT 0.44(L) x 0.37(W) x 0.22(H) m Box 100 pcs / 1box PACKING G.W.: 17kg/box Specification subject to change without notice www.sunny-euro.com SYS1421 series Wall-mount 2.5W~6W Specification subject to change without notice www.sunny-euro.com